Hollow-Fiber Membrane Degassing Module for Inkjet Ink
The EF-AG3-B degasses ink inline in industrial inkjet supply lines. Ink flows outside the hollow fibers, and the vacuum draws dissolved gases through the membrane to reduce bubble formation downstream. Both liquid ports and the vacuum port use NPT 1/8 female threads. Verify degassing and liquid-side pressure drop for the actual ink, flow rate, temperature and vacuum-side absolute pressure, and check compatibility with ink and cleaning fluids.
Drawings and technical support
Click Default configuration to add or remove it; hover to view details.
| Model | EF-AG3-B |
|---|---|
| Product type | Membrane Degasser |
| Dimensions | 159 mm × Ø42 mm |
| Weight | Approx. 100 g |
| Membrane area | Approx. 0.2 m² |
| Initial priming volume | Approx. 40 mL (EF-AG3 series reference value) |
| Hollow-fiber membrane | Poly(4-methyl-1-pentene) (PMP) |
| Housing and end caps | Polypropylene (PP), stainless steel (SUS) |
| Potting resin | Epoxy resin |
| Ports | Two liquid ports and one vacuum port, all NPT 1/8 |
| Liquid and ambient operating temperature | 5–45 °C |
| Maximum liquid-side pressure (gauge) | 200 kPa |
| Vacuum-side pressure for aqueous liquids (absolute) | From the liquid's saturated vapor pressure at operating temperature to 100 kPa |
| Vacuum-side pressure for nonaqueous liquids (absolute) | 1–100 kPa |
| Water test: dissolved oxygen after treatment | < 1.9 mg/L |
| Water test: module pressure drop | < 0.1 kPa |