Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Laboratory automation
< Back

Laboratory Automation Fluidics: Components and Task Validation

Application guide

Laboratory automation connects pumps and valves with workstation layout, containers, liquid classes and task scheduling. Pipetting, microplate handling, dispensing and sample preparation each have working-volume and cycle-time requirements. Record shared-resource use and recovery from interruptions alongside sample identity.

Explore workstation architecture and liquid-handling execution, then use the relevant analytical, nucleic-acid or cell-processing guides to evaluate method results. Disposable tips and fixed probes require different programs; selecting multiple sources does not provide independent parallel supply.

Application guides

Laboratory automation

Laboratory automation Overview
Sample preparation platforms
Automated Pipetting
Microplate dispensing and washing
Reagent dispensing
Workstation fluidic integration

ON THIS PAGE

Configuration Priorities for Five Automated Workstation TypesMatch each workstation action to its container, timing and shared resourcesRoles of commonly used products in this fieldValidate component operating points and application results separatelyExplore related application fields by taskInformation needed to start a configuration discussion

01Configuration Priorities for Five Automated Workstation Types

Compare equipment tasks, then explore the relevant guide
Instrument or workstationMain liquid handling tasksConfirm firstAcceptance priorities
Sample preparation platformsPipetting, washing and product transfer across stationsConsumables, retained material, shared resources and cycle timeWorkstation delivery, residual liquid, recovery and method results
Automated PipettingSingle transfers and multiple dispenses from one aspirationDisplacement method, sealing, liquid class and usable strokeActual received volume, first/last doses and contamination across the sequence
Microplate dispensing and washingWell dispensing and method-required microplate washingPlate type, peak supply/drainage demand, manifold and wash-head heightPer-well delivery, residual liquid and whole-plate method results
Reagent dispensingRepeated dispensing and batch timingTotal cycle volume, start/stop operation, actual formulation and replenishmentFirst, middle and last doses; first dose after a bottle change; affected vessels
Workstation fluidic integrationResource occupancy, module interfaces and fault recoveryState diagrams, vessel identity, confirmed delivered volume and interlocksCheck for misdelivery or repeated actions, with verification after maintenance
  • Read the sample preparation workstation guide
  • Read the automated pipetting guide
  • Explore microplate dispensing and washing
  • Read about reagent dispensing
  • Explore workstation fluidic integration

02Match each workstation action to its container, timing and shared resources

Define the liquid operation at each workstation before choosing its pump: disposable-tip transfer, fixed-probe metering, well washing and waste aspiration have different interfaces and timing. Record the source, destination, working volume and container position together with any shared pump, valve or wash station. Check whether concurrent tasks compete for that resource and whether washing or refill fits the cycle. After an interruption, the controller needs the actual delivery state and container identity before it can choose to resume, repeat or discard an operation.

Instrument or method objective→Fluid paths and operating states→Working volume and cycle time→Candidate configuration→Receipt and method validation
From task requirements to component configuration

03Roles of commonly used products in this field

Open an instrument guide for branch-specific configurations and component coordination
Product categoryMain functions in this field
Air-displacement pipetting pumpDisposable-tip sample preparation; disposable-tip air displacement; tip-based liquid handling at workstations
Syringe pumpFixed-path preparation and transfer; fixed-needle liquid-displacement drive; discrete dispensing by well or group; batch reagent aspiration and dose-by-dose dispensing; discrete metering at stations
Multiport rotary valveSelection of source, station and maintenance paths; selection of reagent sources and dispensing destinations; selection of shared fixed-path resources
Liquid diaphragm pumpWash-station and shared supply; microplate wash and common-liquid supply; workstation shared supply and washing
Gas-liquid diaphragm pumpGas-containing aspiration at shared wash stations; suitable aspiration and waste removal from microplates; suitable shared waste aspiration
Bubble and pressure detectionBubble and pressure signals for workstation monitoring of supply, transfer and drainage; the controller associates events with pipetting stages and potentially affected doses.
Tubing and fittingsStation and shared-resource connections; fixed-path sealing and shared volume; reservoir, manifold and waste connections; source, pump and dispensing-end connections; sealed, serviceable connections between modules
Piston pumpDiscrete metering for suitable fixed-probe configurations
Sampling ProbesFixed-probe interface with the container
Solenoid valveOn-off control of washing and dispensing branches; dispensing-outlet control; branch isolation and state interlocks
Wash probeWell-washing interfaces and aspiration height
Valveless metering pumpsSuitable repeated dosing or continuous supply

04Validate component operating points and application results separately

Record actual delivery, first and last doses, and well-to-well variation by station. Check sample identity, contamination recovery and resource scheduling. Concurrent tests should cover shared-supply and peak waste loads. Interruption tests should distinguish no delivery, partial delivery and completed delivery, checking for wrong destinations or duplicate doses after resumption or retry.

05Explore related application fields by task

  • In vitro diagnostics
  • Life science
  • Analytical instruments
  • Environmental monitoring
  • Synthetic biology

06Information needed to start a configuration discussion

Information for discussing configurations in this field
Information categoryInformation needed
Platform and vesselsStations, needles or tips, plate types and actual receiving locations
Working volume and cycle timeIndividual dose, dose count, well count, batch time and replenishment window
Shared resourcesUse and concurrency conditions for pumps, valves, wash stations, manifolds and waste resources
Restart rulesContainer identity, delivery status, and steps allowed to resume or retry
  • Discuss your operating conditions with an engineer

Related Products

SMTP air-displacement pipetting pump; representative configuration. Select capacity, materials and interfaces for the application.

SMTP air-displacement pipetting pump

HLD rotary-valve syringe pump; representative configuration. Select capacity, materials and interfaces for the application.

HLD rotary-valve syringe pump

DPL60 liquid diaphragm pump; representative configuration. Select capacity, materials and interfaces for the application.

DPL60 liquid diaphragm pump

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

Related Technical Articles

What is a programmable automatic air-displacement pipetting pump?

A programmable automatic air-displacement pipetting pump is a liquid-handling component whose aspiration, dispense, speeds and sequence are set through control commands. This article focuses on air-displacement modules that use disposable tips in OEM instruments, with FOREACH SMTP2 as an example of operation, monitoring and selection limits.

2026-09-28View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Why do multiple wash nozzles deliver different flows from one miniature diaphragm pump?

Calculate demand from the volume and timing of each wash nozzle, separate insufficient pump output from unequal distribution, and verify each branch with collection and pressure measurements.

2026-09-08View Details

What Is a Quick Disconnect Fitting? Male/Female Connections, Valves and Selection

Select a quick disconnect for an instrument fluid path by checking the mating interface, shutoff requirements, tubing, seals and mounting space.

2026-10-20View Details

What Are Female Thread Unions? Selecting Straight, Tee, Y and Bulkhead Connections

Define the connection task first: joining two lines, branching or mounting through a panel. Then match every port and seal before selecting the bore, material and mounting arrangement.

2026-10-21View Details

What Is a Bulkhead Barbed Fitting? Panel Mounting, Tubing Fit and Model Selection

Select a PMB bulkhead hose barb and PMBSN nut by tubing ID, PP/PA material and panel conditions. Use dimensions, diameter ratios and fault symptoms to complete the selection.

2026-10-21View Details

Discuss Your Laboratory Automation Fluidics

Provide a fluid diagram, the actual liquids and pressures in each state. Specify stations and vessels, individual and batch volumes, parallel resources, washing or tip-change strategy, and fault-recovery requirements. Compare suitable configurations against the validation objectives described here.

Contact an engineer