Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Synthetic biology
< Back

Synthetic biology fluidics: components and validation by task

Application guide

Synthetic biology fluidics supports microbioreactors, construct screening, feeding and online sampling. Alongside individual volumes, manage cumulative additions and withdrawals, volume disturbance, sample identity and contamination-control boundaries. Long-running processes require traceable interruption and restart records.

Explore fluid handling for biological workflows and extended process operation. See Laboratory Automation for general robotic workflows and microplate supply and drainage. Validate backflow prevention, tubing pinch-off and sterile isolation separately. Process feedback requires appropriate sensors and controller logic.

Application guides

Synthetic biology

Synthetic biology Overview
Microbioreactors
Biofoundry Construct Development and Screening
Continuous feeding
Online sampling
Bioprocess Integration

ON THIS PAGE

Materials, Sampling and Restart Priorities in Synthetic BiologyDefine additions, withdrawals and allowed interruptions for the processRoles of commonly used products in this fieldValidate component operating points and application results separatelyExplore related application fields by taskInformation needed to start a configuration discussion

01Materials, Sampling and Restart Priorities in Synthetic Biology

Compare equipment tasks, then explore the relevant guide
Instrument or workstationMain liquid handling tasksConfirm firstAcceptance priorities
MicrobioreactorsFeeding, sampling and drainage in small-volume systemsSupply mode, sampling budget, parallel-path isolation and contamination boundariesIndividual and cumulative quantities, representativeness and volume records
Biofoundry Construct Development and ScreeningLiquid handling for construction, cultivation and screeningSample and well identities, actual reagents, consumables and resourcesPer-well delivery, contamination, traceability and screening results
Continuous feedingContinuous or alternating feeding and bottle-change switchingPermissible flow stops, actual backpressure, initial composition and protective-component resistanceFlow trends, cumulative volume and permitted restart after interruptions
Online samplingProcess sampling, path renewal and method-specific pretreatmentAnalyte, delay, discard or recovery strategy, and complete flow pathAnalyte retention, representativeness, volume disturbance and recovery
Bioprocess IntegrationMultibranch feeding, sampling, washing and recoveryOperating conditions by branch, cumulative state, interlocks and maintenance bypassActual delivery, identity, isolation and recovery during extended runs
  • Explore microbioreactors
  • Read the biofoundry construct development and screening guide
  • Read the continuous feeding guide
  • Read about online sampling
  • Explore bioprocess integration

02Define additions, withdrawals and allowed interruptions for the process

Use the culture vessel or screening well as the starting point. Define each feed profile, sampling withdrawal and path-renewal discard, then include them in the volume record over the operating period. Select discrete metering or continuous supply according to the required delivery pattern and permissible interruption, with valves and connections keeping feed, sample, wash and waste destinations distinct. Bubble and pressure signals support controller decisions about fluidic events; culture condition and the complete contamination-control boundary require their own process checks.

Instrument or method objective→Fluid paths and operating states→Working volume and cycle time→Candidate configuration→Receipt and method validation
From task requirements to component configuration

03Roles of commonly used products in this field

Open an instrument guide for branch-specific configurations and component coordination
Product categoryMain functions in this field
Syringe pumpPulse feeding and discrete sampling; fixed-path reagent distribution; intermittent or alternating supply; sample-volume and transfer control; discrete feeding and sampling
Valveless metering pumpsSuitable repeated or continuous feeding; suitable long-duration feed metering; suitable drive for continuous-feed branches
Multiport rotary valveSelection of feeding, sampling and maintenance destinations; selection among sources and target paths; selection of formulation and replenishment sources; selection of sampling, renewal and receiving destinations; connections for multiple process tasks
Tubing pinch-off solutionsIsolation of flexible-tubing feed or sample branches; flexible-branch isolation and maintenance; sampling-tube isolation; flexible-path isolation and module maintenance
Gas-liquid diaphragm pumpSuitable gas-containing waste aspiration; suitable waste and gas-liquid drainage
Bubble and pressure detectionBranch signals for process monitoring and restart control; the controller records abnormal feed intervals and associates events with potentially affected wells, steps and sample identities.
Tubing and fittingsConnections between feed sources, cultures and sample destinations; fixed-station and shared-path connections; extended-run feed paths and loads; connections between process ports, pretreatment and analysis; long-term wetted paths and sealed module connections
Air-displacement pipetting pumpTip-based liquid handling for construction and screening
Liquid diaphragm pumpActual shared wash stations and auxiliary supply
Check valvesBackflow limitation in feed branches
FiltersMethod-required sample treatment

04Validate component operating points and application results separately

Measure individual delivery for discrete feeding, time-window flow and run-total volume for continuous feeding. For sampling, check target representativeness, renewal discard and process-volume records together. Link sample and well identities during construction and screening; after extended-run interruptions, verify actual vessels and completed actions. Evaluate fluid states, process results and contamination boundaries separately.

05Explore related application fields by task

  • In vitro diagnostics
  • Life science
  • Laboratory automation
  • Analytical instruments
  • Environmental monitoring

06Information needed to start a configuration discussion

Information for discussing configurations in this field
Information categoryInformation needed
Biological taskCulture, construct, screening or analytical target and acceptance criteria
Materials and volumesBranch formulations, feed profiles, sampling and discard budgets, and run duration
Flow-path boundariesCulture vessels, shared sections, isolation, materials and cleaning or sterilization procedures
Recovery recordsCumulative delivery, sample identity, unfinished actions and permitted compensation
  • Discuss your operating conditions with an engineer

Related Products

HLD rotary-valve syringe pump; representative configuration. Select capacity, materials and interfaces for the application.

HLD rotary-valve syringe pump

RPL Valveless Metering Pump; representative configuration. Select capacity, materials and interfaces for the application.

RPL Valveless Metering Pump

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

ABD bubble-detection module; representative configuration. Select capacity, materials and interfaces for the application.

ABD bubble-detection module

Related Technical Articles

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Valveless Metering Pump Selection Guide: FOREACH Models and Applications

To select a valveless metering pump, first define the volume per dose and the time available for dispensing. Then check displacement per revolution, drive speed, wetted materials, backpressure and connections, and verify delivery in the actual fluid path. Neither flow rate alone nor the label ‘metering pump’ is enough to select a model.

2026-09-16View Details

Miniature Diaphragm Pump Backflow After Stopping: Check Valves and Anti-Siphon Design

Diagnose reverse flow after a miniature diaphragm pump stops, distinguish it from forward siphoning and residual dripping, and evaluate check-valve behavior, valve sequencing and static sealing in the complete circuit.

2026-09-07View Details

Discuss your synthetic biology fluidics

Provide a fluid diagram, the actual liquids and pressures in each state. Specify reactor volume, feeding time profile, sample/discard budget, isolation requirements and permissible interruptions. Compare suitable configurations against the validation objectives described here.