Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Life science
< Back

Life Science Fluidics: Components and Validation by Task

Application guide

Life science fluid handling is organized around nucleic-acid, cell and protein workflows. Alongside delivered volume, evaluate target recovery, cell condition, surface adsorption and experimental contamination. Define what must be retained and discarded before comparing pumps and connections.

Start with the requirements of your samples and products. For workstation timing and resource coordination, explore laboratory automation; for extended feeding and bioprocess integration, explore synthetic biology. Shared components still require application-specific acceptance criteria.

Application guides

Life science

Life science Overview
Nucleic Acid Processing
Cell culture and transfer
Experimental workflow automation
Protein and antibody processing
Process feeding and sampling

ON THIS PAGE

Acceptance Criteria for Five Life Science WorkflowsChoose the fluid path around the material the experiment must retainRoles of commonly used products in this fieldValidate component operating points and application results separatelyExplore related application fields by taskInformation needed to start a configuration discussion

01Acceptance Criteria for Five Life Science Workflows

Compare equipment tasks, then explore the relevant guide
Instrument or workstationMain liquid handling tasksConfirm firstAcceptance priorities
Nucleic Acid ProcessingSample preparation, washing and eluate recoveryMaterial to retain, extraction architecture, residual liquid and consumablesRecovery, contamination blanks and downstream reactions
Cell culture and transferMedium replenishment and cell-suspension transferDelivery mode, bore size, residence time and actual culture conditionsCumulative replenishment volume, cell recovery and cell condition
Experimental workflow automationLaboratory pipetting, washing and transfers between stationsLiquid classes, wetted-path architecture, consumables and sample identityActual delivered volume, blanks and subsequent experimental results
Protein and antibody processingProtein transfer, buffer selection and sample loadingActual formulation, wetted surfaces, residence time and pressure exposureRecovery through the complete flow path, composition changeover and analytical response
Process feeding and samplingFeeding, sampling and drainage in experimental processesDelivery mode, sample-discard budget, maintenance and contamination-control boundaryIndividual and cumulative quantities, representativeness and restart status
  • Explore nucleic-acid processing
  • Read about cell culture and transfer
  • Explore experimental workflow automation
  • Read the protein and antibody handling guide
  • Read the process feeding and sampling guide

02Choose the fluid path around the material the experiment must retain

Start with the biological material and its receiving vessel: nucleic-acid eluate, a cell suspension and a protein fraction require different handling. Mark which fractions remain in the experiment and which go to waste before selecting metering drives, source-selection valves and wetted materials. Compare delivered volume alongside target recovery, cell condition or adsorption through the complete path. A repeatable buffer dose alone does not establish that the transferred biological material remains suitable for the next step.

Instrument or method objective→Fluid paths and operating states→Working volume and cycle time→Candidate configuration→Receipt and method validation
From task requirements to component configuration

03Roles of commonly used products in this field

Open an instrument guide for branch-specific configurations and component coordination
Product categoryMain functions in this field
Air-displacement pipetting pumpTip-based transfer of samples, reagents and products; robotic pipetting; tip-based protein sample preparation
Syringe pumpReagent metering in fixed flow paths; periodic replenishment and discrete transfer; fixed-path dispensing and reagent transfer; discrete transfer of protein samples and buffers; metering individual feeds and samples
Multiport rotary valveSelection of reagent sources and transfer destinations; selection between workstations or liquid sources; selection of buffers and sample sources; routing for feeding, sampling and maintenance
Bubble and pressure detectionBubble and pressure signals for monitoring transfer and supply interruptions, load changes and protein-processing branches; the controller associates signal events with sample steps and process records.
Tubing and fittingsA complete flow path for recovery assessment; connections between culture vessels and liquid sources; physical flow paths between workstations; all protein-contact surfaces; connections between process vessels and fluid branches
Valveless metering pumpsSuitable repeated or continuous medium supply; suitable repeated and continuous feeding
Liquid diaphragm pumpAuxiliary culture-medium supply and washing; shared washing or replenishment supply; auxiliary buffer supply and washing
Tubing pinch-off solutionsIsolation of flexible-tubing branches; isolation and replacement of flexible-tubing paths
Gas-liquid diaphragm pumpSuitable air-containing wash-station drainage
High-pressure injection valveSwitching pressurized separation paths where required

04Validate component operating points and application results separately

Record delivered volume separately from experimental results. For nucleic acids, assess recovery, residual liquid and downstream usability; for cells, assess recovery and cell condition; for proteins, assess recovery through the complete flow path and analytical response. Include low volumes, sample changeovers, liquid changes and the first cycle after restart. Confirm experimental results even when platform motions have completed.

05Explore related application fields by task

  • In vitro diagnostics
  • Laboratory automation
  • Analytical instruments
  • Environmental monitoring
  • Synthetic biology

06Information needed to start a configuration discussion

Information for discussing configurations in this field
Information categoryInformation needed
Experimental materialNucleic acids, cells or proteins; actual formulations, concentrations and temperatures
Material retention and destinationsSolid-phase or product location, waste and receiving vessels, and allowable residual liquid
Operating conditionsWorking volumes, consumables or fixed paths, contact duration and workstation actions
Acceptance targetRecovery, blanks, cell condition or method response, and interruption handling
  • Discuss your operating conditions with an engineer

Related Products

SMTP air-displacement pipetting pump; representative configuration. Select capacity, materials and interfaces for the application.

SMTP air-displacement pipetting pump

HLD rotary-valve syringe pump; representative configuration. Select capacity, materials and interfaces for the application.

HLD rotary-valve syringe pump

RPL Valveless Metering Pump; representative configuration. Select capacity, materials and interfaces for the application.

RPL Valveless Metering Pump

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

Related Technical Articles

What is a programmable automatic air-displacement pipetting pump?

A programmable automatic air-displacement pipetting pump is a liquid-handling component whose aspiration, dispense, speeds and sequence are set through control commands. This article focuses on air-displacement modules that use disposable tips in OEM instruments, with FOREACH SMTP2 as an example of operation, monitoring and selection limits.

2026-09-28View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Valveless Metering Pump Selection Guide: FOREACH Models and Applications

To select a valveless metering pump, first define the volume per dose and the time available for dispensing. Then check displacement per revolution, drive speed, wetted materials, backpressure and connections, and verify delivery in the actual fluid path. Neither flow rate alone nor the label ‘metering pump’ is enough to select a model.

2026-09-16View Details

Discuss Your Life Science Fluidics

Provide a fluid-path diagram, actual liquids and pressures in each operating state. Specify the nucleic-acid, protein or cell task, retention and waste locations, formulations, and recovery or cell-condition targets. Compare configurations against the validation objectives in this guide.

Contact an engineer