Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/In Vitro Diagnostics
< Back

IVD instrument fluidics: selecting and validating pumps, valves and probes

Application guide

Fluidics in in vitro diagnostic (IVD) instruments deliver samples, reagents and wash solutions to the designated locations on time and remove waste promptly. Priorities differ by instrument: clinical chemistry focuses on sample-to-reagent ratios and carryover; immunoassay on magnetic bead handling and signal background; hematology on dilution and counting channels; coagulation on dispensing, temperature and reaction timing; and molecular diagnostics on nucleic acid recovery, amplification mixture preparation and contamination isolation.

FOREACH piston pumps, syringe pumps and air-displacement pipetting pumps, together with valves, probes, monitoring and connection components, can be combined into fluidic solutions for these tasks. Start by defining how liquids contact components and move through the system. Then select capacity, channels, wetted materials and control methods, and finally validate actual delivered volumes and assay results in the complete instrument.

Scope

This guide covers liquid-handling tasks in five common IVD instrument categories. Configuration options refer to representative architectures; samples, reagents and acceptance conditions are defined by the intended assay method.

Application guide

IVD overview

IVD overview
Clinical chemistry analyzer
Coagulation analyzer
Hematology analyzer
Immunoassay analyzer
Molecular diagnostics

On this page

Fluidic priorities in five diagnostic instrument categoriesFrom assay tasks to fluidic configurationsFluidic roles of common productsTwo validation layers: fluid delivery and assay resultsRelated application areasInformation needed to start a configuration discussionReferences

01Fluidic priorities in five diagnostic instrument categories

Identify the analytical architecture that matches your equipment, then open the corresponding guide. The table lists each guide's main questions; shared topics such as metering and washing are explained in the context of each instrument.

Fluidic priorities in five diagnostic instrument categories
Instrument and guideMain tasksFactors affecting configurationEvaluation metrics
Clinical chemistry analyzerAddition of samples and reagents such as R1/R2; probe and reaction cuvette washingFixed probe or pipette tip; reagent aspiration from individual bottles or supply through dedicated tubing; reusable or disposable reaction cuvettesActual delivered volume, sample carryover and reagent interference
Immunoassay analyzerSample and reagent addition; magnetic bead separation and washing; substrate or trigger reagent additionSolid-phase and readout locations, bead resuspension, washing method and whether signal reagents use dedicated pathsBead retention, residual volume, background and signal
Hematology analyzerWhole-blood sampling, dilution and lysis; counting-channel renewalMetering valve or pump-based metering; channel architecture; use of sheath flowSampling representativeness, dilution ratio, counts and blank recovery
Coagulation analyzerPlasma and reagent addition; prewarming, mixing and timingAssay method, trigger rules, dispensing order and temperature windowActual delivered volume, arrival timing and complete reaction results
Molecular diagnosticsLysis, binding, washing, elution and amplification mixture preparationCombination of fixed liquid supply, tip-based pipetting and magnetic-rod handling; separation of pre- and post-amplification operationsNucleic acid recovery, inhibitor control and negative/positive control performance
  • Clinical chemistry: metering and carryover
  • Immunoassay: washing and background
  • Hematology: dilution and counting channels
  • Coagulation: dispensing and reaction timing
  • Molecular diagnostics: recovery and contamination isolation

02From assay tasks to fluidic configurations

Assay task→Liquid-contact architecture→Operating conditions→Component combination→Application validation
Selection and validation workflow

The flow shows the selection and validation sequence. Valve positions, pump wetted boundaries and operating states still need to be checked for each branch.

Mark liquid sources, destinations and waste outlets on the fluidic diagram, then distinguish three task types: single-volume delivery, continuous supply and washing/flushing. For sample channels, also indicate whether the sample enters the pump chamber. With system-liquid drive, the chamber mainly contacts system liquid, while the probe tip and separation interface require separate treatment. With direct liquid contact, include the pump chamber, valves and tubing in residue and cleaning assessments.

Fixed probes integrate readily with piercing, probe washing and dedicated motion mechanisms, but washing consumes cycle time and wash solution. Disposable tips are replaced after use, reducing repeated cleaning of the wetted front end while requiring tip storage, loading, unloading and disposal. Both approaches require aspiration and dispense programs to be adjusted and validated with actual liquids; settings from similar instruments cannot simply be reused.

Dedicated channels suit liquids requiring reduced switching residue or tightly controlled storage conditions. Shared metering channels reduce the number of metering units but add routing, flushing and first-dose recovery steps. Include these steps in the complete cycle when comparing solutions, rather than considering pump running time alone.

Common configuration questions and trade-offs
Configuration questionCompare firstTrade-offs
Wide variation in individual dose volumeMinimum, routine and maximum delivered volumes; whether auxiliary aspiration/dispense steps consume strokeLarger capacity can reduce refills; smaller capacity can use more of the stroke for small doses. Actual delivery accuracy must still be validated at the receiving position.
Sequential addition from multiple liquid sourcesValve port assignment, shared volume and worst-case switching sequenceShared channels can reduce component count; dedicated channels can reduce flushing and cross-effects, but generally require more installation space and cost.
Liquid supply to multiple stationsNumber of simultaneous stations, peak flow, pressure fluctuations and refill windowCentral supply simplifies management, but metering and on/off control must still be implemented at each station.
Recovery after an alarmStage at alarm occurrence, commanded volume, state feedback and sample or cuvette IDThe instrument software associates the event with affected samples, cuvettes or wells. Without actual metering feedback, commanded volume must not be recorded as measured delivered volume.

Further technical reading

  • Piston Pump Accuracy, Repeatability and Resolution Explained

03Fluidic roles of common products

The table lists tasks that component categories can perform in representative architectures, not their full range of applications. First establish whether the equipment uses fixed liquid supply, tip-based pipetting or fixed probes; then select configurations for the actual liquids, operating volumes and cycle times.

Fluidic roles of common products
ComponentClinical chemistryImmunoassayHematologyCoagulationMolecular diagnostics
Piston pumpSample and reagent meteringSample and reagent meteringPump-based metering or system-liquid drivePlasma and reagent meteringFixed liquid supply, matched to the design
Syringe pumpReagent and diluent aspiration/dispenseSequential metering of multiple reagentsDiluent metering and transfer; continuous supply requires planned refillsReagent preparation and metered aspiration/dispenseReagent dispensing through fixed fluidics
Air-displacement pipetting pumpTip-based sample dispensing and transferTip-based sample dispensing and transferTip-based sample dispensing and transferTip-based sample dispensing and transferTransfer of samples, eluates and amplification mixtures
Liquid diaphragm pumpProbe and reaction cuvette wash supplyWash-station and probe-wash supplyLiquid-source replenishment and washingProbe-wash supplyReagent predistribution or wash-station supply
Gas–liquid diaphragm pumpAspiration of air-containing waste liquidWash-station waste removalRemoval of air-containing wash wasteWaste aspiration and removal, matched to the designAspiration through a fixed waste branch
Rotary valve / solenoid valveLiquid-source selection / branch on/off controlPath selection and signal-reagent isolationPath selection; metering valve configured separatelyReagent and wash-path controlRouting and isolation of fixed reagent branches
Sampling probe / wash probeSampling, dispensing and reaction cuvette washingDispensing, wash-liquid addition and aspirationWhole-blood sampling and washingPlasma dispensing and probe washingFixed-probe sampling and dispensing
Bubble and pressure detectionAspiration/dispense anomaly signalsDispensing and washing anomaly signalsSampling and counting-channel anomaly signalsDispensing-stage anomaly signalsTransfer and fixed-supply anomaly signals
Tubing and fittingsConnection from metering unit to probe tipReagent, wash and waste connectionsSampling, dilution and counting connectionsSample and reagent fluidic connections (consider delay, heat loss and assembly consistency)Transfer and supply connections (consider adsorption and residue)
  • EA, SM and TM piston pumps: compare capacity, installation space, interfaces and all wetted materials at routine dose volumes. Establish system-liquid drive or direct liquid contact before configuring valves and probes.

Sources:[1]

  • HMD / HLD syringe pumps: HMD uses solenoid valves for routing, with single- and multiple-metering-channel configurations in the series. HLD3/HLD6 use one metering unit with a multiport rotary valve for sequential aspiration and dispensing. Valve port count indicates selectable paths and must be distinguished from the number of independent metering channels.

Sources:[5][2]

  • SMTP2 / SMTP4 air-displacement pipetting pumps: prioritize evaluation of SMTP2 when integrated drive and process detection are required; evaluate SMTP4 when the instrument supplies drive and detection. Both require confirmation against actual liquid volumes, tips, motion mechanisms and cycle times.

Sources:[3]

  • Liquid / gas–liquid diaphragm pumps: in the washing branches described here, liquid diaphragm pumps supply wash liquid and gas–liquid diaphragm pumps aspirate and remove air-containing waste. Select each task separately for installed resistance, peak load, medium and duty cycle. Per-cuvette volume is determined by the selected metering and station-control arrangement and validated at the receiving position.

Sources:[4]

Capacity narrows the candidate range. Small-dose delivery accuracy and continuous operation capability require validation at actual operating points; analytical results also require evaluation with the complete instrument method.

Further technical reading

  • What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation
  • What Are Cleaning, Wash and Rinse Pumps in IVD Systems, and Why Are Miniature Diaphragm Pumps Used?
  • IVD Waste Aspiration: Liquid Pump or Vacuum Pump? Direct vs Indirect Aspiration

04Two validation layers: fluid delivery and assay results

Layer one validates fluid delivery: use the intended liquid with the actual probes, tubing, valve positions and action sequence. Measure delivered volume and repeatability at the receiving position, and check switching residue, wash coverage and waste removal. For small volumes, select gravimetric or tracer methods as appropriate and control errors from evaporation, density conversion and the measuring apparatus.

Layer two validates assay results: clinical chemistry evaluates carryover and reagent interference; immunoassay evaluates background and signal; hematology evaluates dilution, counts and blanks; coagulation evaluates the complete reaction; molecular diagnostics evaluates nucleic acid recovery, reaction inhibition and contamination control. Passing volume tests does not remove the need for this layer.

Cover minimum, routine and maximum operating volumes, plus low source levels, bottle changes, restart after standby and the first cycle after maintenance—conditions that can alter filling or residue. Record liquid, temperature, probe/tubing configuration, program version and measurement method to help locate the cause of anomalies.

Records and decisions for different operating states
Operating stateWhat to recordDecision supported
Routine cycleActual delivered volume, cycle time, pressure or bubble signals, assay resultsEstablish a normal baseline and acceptable variation range
First dose and liquid changePriming and flushing steps; first-dose and subsequent-dose performanceDefine the recovery procedure, required time and reagent consumption
Simultaneous operation of multiple stationsSupply pressure, peak flow entering the waste system and waste-removal statusConfirm that central supply and waste removal meet concurrent operating demands
Recovery after faults or maintenanceStage, valve position and affected samples, cuvettes or wells; not delivered, partially delivered, fully delivered or unknown stateDecide whether to continue, repeat or stop; retain traceable records

Acceptance targets for carryover, background and nucleic acid recovery must be defined separately for the intended instrument, analyte, assay method and project requirements.

05Related application areas

This page starts from assay requirements for samples, reagents and results. For microplate operations, pipetting robots and workstation scheduling, see laboratory automation. For extraction, purification or sample processing in research workflows, see life science.

  • Life science

    Nucleic acid, cell and protein processing: evaluate target recovery, cell condition, surface adsorption and contamination in addition to delivered volume.

  • Laboratory automation

    Pipetting, microplates, dispensing and sample preparation: focus on dose and cycle time, resource scheduling and fault recovery.

  • Analytical instruments

    Chromatography, elemental analysis, water analysis and sample preparation: distinguish discrete metering, auxiliary continuous supply, washing and waste removal.

  • Environmental monitoring

    Field water samples, wastewater and gas pretreatment: focus on sample representativeness, washing, waste removal and long-term maintenance.

  • Synthetic biology

    Microbioreactors, screening, feeding and online sampling: manage cumulative material quantities, volume disturbances, contamination control and recovery during long-term operation.

06Information needed to start a configuration discussion

Provide a fluidic diagram showing sources, valves, pumps, probes and waste destinations, together with as much of the information below as possible. We can then narrow the choices for capacity, materials, channels and control interfaces. Items not yet known may be marked “to be determined.”

Information needed to start a configuration discussion
Information categoryInformation required
Instrument and methodInstrument type, assay method and sample type; fixed probe or disposable tip; direct sample contact or system-liquid drive
Actual operating pointMinimum / routine / maximum dose or flow; liquid composition; inlet conditions and outlet load; liquid-contact temperature
Timing and spaceComplete action cycle, parallel stations, refill window, motion and installation space, communication and feedback requirements
Washing and waste removalWash-liquid types, surfaces to cover, flushing consumption, peak waste flow and its duration, waste isolation and maintenance method
Acceptance and faultsAccuracy / repeatability targets at actual operating points, assay-result requirements and rules for handling affected samples after alarms
  • Discuss your operating conditions with an engineer

References

View references (5)
  1. [1]FOREACH | EA, SM and TM piston pump series
  2. [2]FOREACH | HLD rotary-valve syringe pump series
  3. [3]FOREACH | Air-displacement pipetting pumps
  4. [4]FOREACH | Miniature diaphragm pumps
  5. [5]FOREACH | HMD solenoid-valve syringe pump series

Related Products

EA Standard piston pumps

EA Standard piston pumps

HLD Rotary-valve syringe pumps

HLD Rotary-valve syringe pumps

DPL30 Liquid diaphragm pumps

DPL30 Liquid diaphragm pumps

DPGL800 Gas–liquid diaphragm pumps

DPGL800 Gas–liquid diaphragm pumps

Related Technical Articles

Piston Pump Accuracy, Repeatability and Resolution Explained

Learn why theoretical volume per step is not the minimum reliable dose, and how accuracy, repeatability, valves, bubbles and working stroke affect dispensing results.

2026-09-06View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

What Are Cleaning, Wash and Rinse Pumps in IVD Systems, and Why Are Miniature Diaphragm Pumps Used?

Cleaning pump, wash pump and rinse pump usually name different duties within an IVD cleaning sequence, not three fixed pump mechanisms. Selection starts with wash volume, cycle rate, line resistance, wetted materials, and whether the duty is liquid supply or waste aspiration.

2026-09-03View Details

IVD Waste Aspiration: Liquid Pump or Vacuum Pump? Direct vs Indirect Aspiration

Probe washing, reaction-cup cleaning, and routine waste removal in IVD instruments are all described as “waste aspiration.” Yet whether waste passes directly through a liquid pump or first enters a collection bottle while a vacuum pump creates negative pressure leads to entirely different selection logic.

2026-08-09View Details

What Is a Quick Disconnect Fitting? Male/Female Connections, Valves and Selection

Select a quick disconnect for an instrument fluid path by checking the mating interface, shutoff requirements, tubing, seals and mounting space.

2026-10-20View Details

What Are Female Thread Unions? Selecting Straight, Tee, Y and Bulkhead Connections

Define the connection task first: joining two lines, branching or mounting through a panel. Then match every port and seal before selecting the bore, material and mounting arrangement.

2026-10-21View Details

What Is a Bulkhead Barbed Fitting? Panel Mounting, Tubing Fit and Model Selection

Select a PMB bulkhead hose barb and PMBSN nut by tubing ID, PP/PA material and panel conditions. Use dimensions, diameter ratios and fault symptoms to complete the selection.

2026-10-21View Details

Discuss Your IVD Fluidic Requirements

Share the instrument type, sample and reagent properties, working volumes, cycle timing, fluid path and acceptance criteria so we can discuss suitable components and prototype evaluation.

Discuss your application