Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Life science/Nucleic Acid Processing
< Back

Nucleic-Acid Processing: Fluidics for Washing, Elution and Recovery

Application guide

Nucleic acid processing must balance impurity removal against target retention at every transfer. The same aspiration and dispensing action may send liquid to waste during washing but recover the product during elution. Specify what each step retains and discards before choosing needles, tips, pumps and paths.

Instruments and methods covered

This page covers liquid handling in nucleic acid processing. For magnetic-bead extraction, first establish whether the architecture transfers liquid or beads. Pumps serve only the liquid operations actually required; separation steps do not all involve pumping through fixed tubing.[4]

Application guides

Nucleic acid processing application guide

Nucleic acid processing fluidics overview
Syringe pumps in nucleic acid processing
Air-Displacement Pipetting Pumps for Nucleic Acid Processing
Sample preparationWashing and elution
Multiport rotary valves in nucleic acid processing
Path switching
Bubble and pressure sensing in nucleic-acid processing
Tubing and fittings in nucleic-acid processing

ON THIS PAGE

Locate the task in the fluid path firstCommon product roles and application guidesOperating requirements differ by stepSample preparation: record retained fractions, waste and reagentsWashing and elution: retain the solid phase and recover the productPath switching: isolate eluate and wasteConnection materials: validate recovery through the complete pathExplore configurations through product application guidesValidate the complete cycle through application resultsCommon selection and recovery questionsReferences

01Locate the task in the fluid path first

Sample processing→Binding or separation→Washing and supernatant removal→Elution→Product collection
Illustrative task sequence. Confirm sampling, washing, waste and monitoring branches separately against the instrument drawings.

Arrows indicate task relationships, not that every component is connected in series in one tube. Check valve positions, pump wetted boundaries and operating states for each branch.

Translate recovery targets and contamination limits into receiving volume, residual-liquid limits, aspiration height and consumable choices. Measure nucleic-acid losses on surfaces and through connections over the complete workflow; material names alone cannot establish recovery.

02Common product roles and application guides

Explore product applications by their role in the instrument
Product categoryRole in this instrument
Syringe pumpReagent metering in fixed flow paths
Air-displacement pipetting pumpTip-based transfer of samples, reagents and products
Multiport rotary valveReagent-source and transfer-destination selection
Bubble and pressure detectionDetecting loss of liquid supply and bubbles during transfer
Tubing and fittingsBuild a complete path for recovery assessment
  • Syringe pumps in nucleic acid processing
  • Air-Displacement Pipetting Pumps for Nucleic Acid Processing
  • Multiport rotary valves in nucleic acid processing
  • Bubble and pressure sensing in nucleic-acid processing
  • Tubing and fittings in nucleic-acid processing

03Operating requirements differ by step

Define fluid-path responsibilities before examining individual operations
StageTask categoryOperating conditions to define
Sample preparation: record retained fractions, waste and reagentsDispensing operating conditionsDose per operation, total cycle volume, replenishment/bottle-change interval, backpressure and receiving geometry
Washing and elution: retain the solid phase and recover the productSolid-phase retention, washing and recoverySolid-phase location and retention target, wash cycles, aspiration height, residue, destination and downstream assay requirements
Path switching: isolate eluate and wasteValve-path requirementsAll ports, valve states, pressures in each state, shared volume and flushing volume
Connection materials: validate recovery through the complete pathConnection requirementsTubing ID/OD, length, interface geometry, pressure, materials and maintenance method

04Sample preparation: record retained fractions, waste and reagents

Assign container identities and destinations to each step, and establish programs for the actual lysis and binding formulations. After an interruption, confirm whether the product has already been transferred before deciding whether to complete the step or stop.

  • Sample preparation

05Washing and elution: retain the solid phase and recover the product

Adjust aspiration height to the solid-phase position and vessel geometry, and assess low-volume collection separately for elution. Evaluate recovery, residual liquid and the next reaction. Volume accuracy alone does not establish washing effectiveness.

  • Washing and elution

06Path switching: isolate eluate and waste

Use a port-state table to verify product-channel connections during operation, cleaning and shutdown. Define the destination of liquid displaced from shared sections.

  • Path switching

07Connection materials: validate recovery through the complete path

Include tubing, probes, valves and fittings in recovery tests. Before shortening tubing, confirm that installation, maintenance access and receiving geometry remain feasible.

  • Tubing and fittings in nucleic-acid processing

08Explore configurations through product application guides

  • Syringe pumps in nucleic acid processing
  • Air-Displacement Pipetting Pumps for Nucleic Acid Processing
  • Multiport rotary valves in nucleic acid processing
  • Bubble and pressure sensing in nucleic-acid processing
  • Tubing and fittings in nucleic-acid processing

09Validate the complete cycle through application results

Record product volume, recovery and downstream results, and check sample-to-sample contamination.

Plan operating-point validation and fault investigation for each step
Step to validateMeasurements or observationsPriority troubleshooting checks
Sample preparation: record retained fractions, waste and reagentsUse actual media to check first, middle and last doses and delivery after bottle changes; confirm received volume and timing rather than substituting commanded steps for volumeEmpty sources, bubbles, nozzle droplets and backpressure changes affect first or last doses
Washing and elution: retain the solid phase and recover the productEvaluate solid-phase loss, post-wash residue and downstream assay background or nucleic-acid recovery togetherInsufficient capture, incorrect aspiration height, uneven coverage or pooling may impair washing and recovery
Path switching: isolate eluate and wasteCheck unintended connections, leakage, backflow and post-switching residue in each state; measure flushing volume and arrival delay through the complete pathMisalignment, shared-segment residue or abnormal switching pressure may affect the next task
Connection materials: validate recovery through the complete pathTest sealing and actual delivery, and compare analyte recovery and blanks through the complete flow path.Adsorption, hold-up or maintenance contamination can reduce recovery despite acceptable volume

Extraction and library-preparation liquid handling differ in contamination and outcome requirements. Confirm research workflows and clinical diagnostic methods separately.

10Common selection and recovery questions

Does removing more wash liquid always improve recovery?

Assess solid-phase loss, residual wash liquid and subsequent elution together. Establish the method's permitted residual volume and what must be retained before adjusting height and motion. Emptying alone cannot establish process performance.

What should be checked when volume passes but downstream reactions fail?

Check product recovery, residual wash liquid or inhibitors, and contamination blanks separately to identify whether the change occurs during extraction, transfer or mixture preparation.

References

View references (4)
  1. [1]FOREACH SMTP air-displacement pipetting pumps: configurations and specifications
  2. [2]FOREACH syringe pumps: configurations and specifications
  3. [3]FOREACH fittings: configurations and specifications
  4. [4]Thermo Fisher KingFisher: Binding, Washing and Elution by Magnetic-Bead Transfer

Related Products

SMTP air-displacement pipetting pump; representative configuration. Select capacity, materials and interfaces for the application.

SMTP air-displacement pipetting pump

HLD rotary-valve syringe pump; representative configuration. Select capacity, materials and interfaces for the application.

HLD rotary-valve syringe pump

Rigid-tubing fittings; representative configuration. Select capacity, materials and interfaces for the application.

Rigid-tubing fittings

Related Technical Articles

What is a programmable automatic air-displacement pipetting pump?

A programmable automatic air-displacement pipetting pump is a liquid-handling component whose aspiration, dispense, speeds and sequence are set through control commands. This article focuses on air-displacement modules that use disposable tips in OEM instruments, with FOREACH SMTP2 as an example of operation, monitoring and selection limits.

2026-09-28View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss Your Nucleic Acid Processing Fluidics

Provide a fluid-path diagram, actual liquids and pressures in each operating state. Specify tips and liquid classes, volumes and residue limits, bore sizes, tube-end positioning and materials. Compare configurations against the validation objectives in this guide.

Contact an engineer