Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
Frequently Asked QuestionsDatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Frequently Asked Questions
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Pipetting Pumps/SMTP2/SMTP2-520
FOREACH SMTP2-520 Air Displacement Pipettor for OEM Integration, LTE072 (72 mm)

Air Displacement Pipettor for OEM Integration

SMTP2-520 · 1000 μL · Tip adapter LTE072 (72 mm). For vessel access layouts requiring a longer adapter projection. Assess the 72 mm configuration for deeper vessels or taller tube racks, checking opening diameter, collision clearance and the intended aspiration position.

Integrated drive and control support pLLD/cLLD/hLLD liquid-level detection, blockage and tip-presence detection, automatic tip ejection, and RS232, RS485 and CAN communication. The instrument supplies positioning motion, disposable tips and liquid-specific aspiration and dispense settings.

Adapter length is not a guaranteed aspiration depth and does not change the 1000 μL nominal capacity. Actual reach depends on the tip, mounting position, vessel geometry and positioning travel. Validate accuracy and repeatability with the intended liquid, tip and working volumes.

Typical Applications:

Sample transfer, Reagent dispensing, Automated pipetting

Model:SMTP2-520
Product nameSMTP2-520 1000 μL programmable air-displacement pipetting pump
ModelSMTP2-520
Tip adapterLTE072 (72 mm)
Product seriesSMTP2 programmable air-displacement pipetting pump
Pipetting methodAir displacement
Nominal capacity1000μL
Drive designFour-wire bipolar stepper motor with lead screw
Volumetric resolutionStandard mode: 0.319 μL/step; high-resolution mode: 0.02 μL/microstep
Full-stroke step countStandard mode: 3143 steps; high-resolution mode: 48000 microsteps
Liquid-level detectionPressure-based pLLD, capacitive cLLD and hybrid hLLD
Tip blockage detectionSupported (TPBD)
Tip presence detectionSupported (TPON / TPOFF)
Automatic tip ejectionSupported (ADTP)
Communication interfacesRS232 / RS485 / CAN
Cascading capacityUp to 16 pumps
Operating noise<60 dBA; indoor use only
Operating environment15°C to 40°C; 20% to 95% RH at 40°C; non-condensing
Storage environment-20°C to 65°C; 30% to 85% RH; non-condensing
Fluid temperature15°C to 40°C
Power requirements24VDC 500mA
Tip compatibilityDisposable and custom tips can be adapted; compatibility must be confirmed for the instrument geometry

Typical applications

SMTP2-520 · 1000 μL · Tip adapter LTE072 (72 mm). For vessel access layouts requiring a longer adapter projection. Assess the 72 mm configuration for deeper vessels or taller tube racks, checking opening diameter, collision clearance and the intended aspiration position.

Reach and clearance assessment for deeper vessels

For vessel access layouts requiring a longer adapter projection. Assess the 72 mm configuration for deeper vessels or taller tube racks, checking opening diameter, collision clearance and the intended aspiration position.

Adapter length is not a guaranteed aspiration depth and does not change the 1000 μL nominal capacity. Actual reach depends on the tip, mounting position, vessel geometry and positioning travel. Validate accuracy and repeatability with the intended liquid, tip and working volumes.

Sample preparation: transfer from the original sample tube to a processing vessel

In a sample preparation module, the pipetting unit loads a tip, locates the liquid surface, aspirates the specified sample volume and transfers it to the destination vessel. This task is called sample transfer or sample pipetting. Key considerations are the aspiration position, actual aspirated volume and residual liquid control when changing samples.

SMTP2 liquid-level and tip detection can support the instrument’s assessment of sampling status, while tip blockage detection can signal abnormal aspiration. Different sample levels, viscosities and vessel-bottom geometries still require validation together with the positioning axes and aspiration parameters.

Analytical workflows: reagent dispensing and reaction setup

Adding reagent to a reaction tube or well is reagent dispensing; adding samples, reagents and buffers sequentially according to a recipe is reaction setup. In both steps, the pipetting unit must deliver the set volume to the destination vessel and control carryover between samples.

SMTP2 can provide aspiration, dispensing and detection signals for these automated pipetting stations. Establish a liquid class for the specific liquid, coordinating aspiration speed, dwell time, tip withdrawal and dispensing height. The timing of disposable-tip changes should be included in the same workflow.

Installation selection inputs

Adapter length is not a guaranteed aspiration depth and does not change the 1000 μL nominal capacity. Actual reach depends on the tip, mounting position, vessel geometry and positioning travel. Validate accuracy and repeatability with the intended liquid, tip and working volumes.

2D Drawing Not Available Yet

To request a 2D drawing for this product, please click “Add Drawing” above.

Datasheet not yet available

The datasheet for this product has not been uploaded yet.

Frequently Asked Questions

No. 72 mm describes the LTE072 adapter, not a guaranteed aspiration depth. Check the effective tip length, vessel opening, mounting reference and positioning travel together, including level detection, aspiration position and clearance above the vessel bottom.

1000 μL is the nominal capacity; 0.02 μL per microstep is the drive increment in high-resolution mode, not a minimum reliable transfer volume. The datasheet includes a 2 μL performance point using a 20 μL tip, but this does not establish suitability for every liquid and tip. Define the usable range against the intended volume, tip, liquid, accuracy and repeatability requirements.

Read performance by tip size, actual volume and dispensing mode. On datasheet page 14, a 1000 μL tip dispensing 100 μL in Single mode has Accuracy ≤2% and Precision 0.75%; the corresponding Multiple row lists ≤3% and 2%. That page does not fully specify the test liquid, tip part number or statistical method. Confirm those conditions before project acceptance; these figures are not a universal guarantee.

pLLD is pressure-based liquid level detection, cLLD is capacitive detection and hLLD is hybrid detection. SMTP2 specifications support all three. Selection requires checking liquid properties, tip design, equipment grounding and axis motion, then validating detection positions and trigger conditions with the intended liquid. No method should be assumed to be best for every application.

The datasheet includes Multiple dispensing performance, providing a basis for evaluating one aspiration followed by several dispenses. The instrument must implement the required commands and motions. Check the total planned delivery and method allowances against available pump and tip capacities, and verify the first, intermediate and final aliquots separately. Nominal capacity alone does not guarantee a particular number of aliquots.

Related Videos

Liquid Level Detection for Automated Pipetting

Liquid level detection

Fluid Control Components for Laboratory Instruments

Company overview

Related Technical Articles

What is a programmable automatic air-displacement pipetting pump?

A programmable automatic air-displacement pipetting pump is a liquid-handling component whose aspiration, dispense, speeds and sequence are set through control commands. This article focuses on air-displacement modules that use disposable tips in OEM instruments, with FOREACH SMTP2 as an example of operation, monitoring and selection limits.

2026-09-28View Details

Need help selecting a pipetting pump?

Share the volume range, tip specification, liquid-level and clog-detection requirements, communication interface, installation space, and control method. The Foreach engineering team can help confirm a suitable configuration.

Contact an Engineer