Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
Frequently Asked QuestionsDatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Frequently Asked Questions
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Pumps/Valveless Metering Pump/RPL-P15
FOREACH RPL-P15 valveless metering pump, front three-quarter view

RPL-P15 Ceramic Piston Metering Pump for Reagent Filling in Life Sciences

RPL-P15 is a valveless ceramic piston metering pump for larger dispense volumes and higher liquid delivery requirements. Mechanically adjustable displacement of 300–1200 μL/rev and a speed range of 5–300 rpm provide a flow range of 1.5–360 mL/min. Typical tasks include diagnostic reagent bottle filling, buffer dispensing, reservoir replenishment and metered supply to analytical instruments.

The ceramic piston rotates and reciprocates to draw in liquid, discharge it and switch between ports without separate check valves. A larger displacement reduces the number of revolutions needed for a given fill. For example, 10 revolutions at 1000 μL/rev give a calculated fill volume of 10 mL. Different fill volumes can be accommodated by changing revolution count or displacement, followed by output calibration at the required filling cycle.

The configuration shown combines a polyvinylidene fluoride (PVDF) pump head and plugs with an aluminium oxide (Al₂O₃) ceramic piston and cylinder set. G1/8 process ports connect the working-fluid circuit, while 1/4-28 UNF-2B rinse ports allow flushing around the piston to help limit residue buildup and crystallization. The pump measures 78 × 78 × 160 mm and weighs 900 g.

Typical Applications:

Reagent filling systems: volumetric bottle filling, Laboratory preparation workstations: premixed buffer dispensing and reservoir replenishment, Analytical instrument supply modules: metered liquid delivery

Model:Select a configuration
Product typeRPL Single-Head Valveless Metering Pump
Displacement per revolution300–1200 μL/rev
Speed5–300 rpm
Accuracy<2%
Repeatability<0.5%
Pressure ratingMax 150 kPa
Service life20,000,000 cycles
Pump head materialpolyvinylidene fluoride (PVDF)
Plug materialpolyvinylidene fluoride (PVDF)
Ceramic setaluminium oxide (Al₂O₃)
Working-fluid portG1/8
Wash-fluid port1/4-28 UNF-2B
Overall dimensions78 × 78 × 160 mm
Weight900 g
ConfigurationCustom configuration

Flow ranges are calculated from displacement per revolution and speed. Calibrate actual delivery with the intended liquid, backpressure and fluid circuit.

Displacement per revolution is not the dose or minimum reliable volume; verify actual output with the drive, liquid and circuit.

Accuracy, repeatability and life require the applicable test conditions. Confirm permitted working backpressure separately from the pressure rating.

Typical applications

RPL-P15 addresses delivery and filling tasks that need greater displacement per revolution. It may serve as a reagent filling pump, buffer dispensing pump or quantitative supply pump. Filling controls volume per container, continuous supply controls volume per unit time, and reservoir replenishment must coordinate with level control.

Diagnostic reagent production: volumetric bottle filling

In reagent production or laboratory packaging, liquid travels from a supply vessel through the pump and filling tip into each bottle. RPL-P15 can be assessed as a reagent filling pump or volumetric dispensing pump. Balance per-container volume with cycle time; different displacement settings require different revolution counts for the same target fill.

Calculation example: a nominal 5 mL fill at 1000 μL/rev requires 5 complete revolutions. At a constant 150 rpm, pump running time is theoretically 2 seconds. Container indexing, acceleration, stopping and tip motion are additional; this is not a production-line throughput claim. Calibrate the actual volume delivered at the outlet.

Before increasing speed, check inlet supply, tip restriction and droplet release. For foaming liquids, assess dispensing height and motion as well. Measure both consecutive fills and the first fill after a pause to evaluate the complete station rather than the pump alone.

Laboratory preparation: buffer dispensing and replenishment

A pump distributing premixed buffer among containers may be called a buffer dispensing pump; one refilling an intermediate reservoir may be called a replenishment pump. Neither task is the same as preparing buffer from two liquids. Single-head RPL-P15 does not independently control a concentrate-to-diluent ratio.

For repeated dispensing, match volume, displacement and operating cycles. For reservoir replenishment, level measurement or an instrument command determines start and stop. Level sensing, dry-run protection and overflow prevention belong to the system design and cannot be assumed to be included with the pump.

Include a compatible shutdown rinse when using salt-containing buffers to limit residue drying and crystallization around the piston. The G1/8 working-fluid port and 1/4-28 UNF-2B wash-fluid port serve different circuits. Connect them according to the configuration drawing and check for air introduced after replenishment.

Analytical instrument supply: continuous metered delivery

When an instrument needs liquid over an extended period, RPL-P15 can be assessed as a liquid metering pump or quantitative supply pump. Unlike per-container filling, the primary inputs are average flow, run duration and the downstream process tolerance for flow fluctuations.

Estimate nominal average flow as displacement per revolution multiplied by speed. Calculation example: 500 μL/rev × 120 rpm = 60000 μL/min, or 60 mL/min. This is an average value, not constant instantaneous flow or a substitute for measurement with the actual liquid and backpressure.

Measure output collected over a defined interval at the actual outlet resistance, and check the effect of pulsation on the downstream process. Adding a mixer or other restriction requires renewed backpressure and inlet-supply checks. Valveless construction does not by itself guarantee pulseless flow or unlimited continuous operation.

Define the fluidic task and configuration

Provide liquid composition, dose volume or continuous flow, allowable delivery time, daily run duration, inlet conditions, outlet backpressure and drive requirements. Use these inputs to size displacement and timing, then verify output in the actual circuit. Application directions are not claims of validation in every listed instrument.

Preview DrawingView the technical drawing for RPL-P15.
Download RPL-P6.35 / RPL-P15 (English, 001 / 2025-07) PDF
Preview RPL-P6.35 / RPL-P15 (English, 001 / 2025-07) Datasheet

Frequently Asked Questions

Their displacement ranges are 300–1200 μL/rev and 50–300 μL/rev respectively. RPL-P15 is an option for larger-volume filling and liquid supply. Compare the target fill volume, delivery time and any small-dose requirements, rather than choosing by flow alone.

No. It is displacement per revolution; flow also depends on speed. For example, 500 μL/rev × 120 rpm gives a nominal average flow of 60 mL/min. Calibrate the actual flow with the liquid and backpressure in use. Average flow does not imply pulse-free delivery.

It is a single-head pump for metering or dispensing one liquid. Proportional preparation of two liquids requires another fluid path and suitable control. For fixed concentrate-to-diluent ratios of 1:9 or 1:19, a DRPL dual-head configuration can be assessed separately.

The shown configuration uses a polyvinylidene fluoride (PVDF) head and plug, an aluminium oxide (Al₂O₃) ceramic set, a G1/8 working-fluid port and a 1/4-28 UNF-2B wash-fluid port. Check the reagent and cleaning liquid against all wetted components, not just the pump head. Confirm the drive, mounting and interfaces for the supplied configuration.

Confirm the definitions and test conditions, including liquid, temperature, displacement, speed and backpressure. A pressure rating is not automatically the permitted operating backpressure, and cycle life is not a guarantee under every condition. Valveless construction does not mean that a complete instrument needs no switching or shutoff valves.

Related Technical Articles

Metering Pump Dosing Inaccurate or Inconsistent? Causes and Troubleshooting

When the same program still produces unstable dispense volumes, first classify the error pattern, then check bubbles, inlet supply, fluid properties, tubing, the outlet and motor settings. This guide provides a practical first-pass troubleshooting method.

2026-09-24View Details

What Is a Valveless Metering Pump? Working Principle, Applications and Selection

A valveless metering pump is a positive-displacement pump that combines rotary and axial reciprocating piston motion to switch the fluid path, draw liquid in and discharge it. Its pumping mechanism does not rely on conventional inlet and outlet check valves. It can serve reagent dispensing, titration, filling and two-fluid proportional delivery, but metering performance still has to be verified with the actual fluid, pressure, tubing, drive and cleaning conditions.

2026-09-21View Details

Valveless Metering Pump Selection Guide: FOREACH Models and Applications

To select a valveless metering pump, first define the volume per dose and the time available for dispensing. Then check displacement per revolution, drive speed, wetted materials, backpressure and connections, and verify delivery in the actual fluid path. Neither flow rate alone nor the label ‘metering pump’ is enough to select a model.

2026-09-16View Details

Confirm the RPL-P15 configuration for your instrument

Provide liquid composition, dose volume or continuous flow, allowable delivery time, daily run duration, inlet conditions, outlet backpressure and drive requirements. Use these inputs to size displacement and timing, then verify output in the actual circuit. Application directions are not claims of validation in every listed instrument.

Submit requirements