Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control Series
Applications
IVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Valves/SV10 Solenoid Valves/2-Way Miniature Solenoid Valves
FOREACH SV10-2 2-way miniature solenoid valve, showing threaded ports and base seals

FOREACH 2-way miniature diaphragm solenoid valve for diluent and wash-fluid on/off control, with normally closed or normally open variants

FOREACH SV10 2-way miniature solenoid valves use a rocker diaphragm to open or close reagent and wash-fluid lines in automated equipment. Choose normally closed or normally open operation to match the required state without power.

A normally closed valve closes the connection without power and opens it when energized. A normally open valve does the reverse. Coordinate the valve with the pump and control program: the valve controls the connection, while a pump or pressure difference moves the fluid.

Choose SV10-P for manifold mounting, SV10-M6 or SV10-U28 for threaded fittings, or SV10-B16 for flexible tubing. Select the wetted materials for your fluids and a separate 12 V DC or 24 V DC coil version for the equipment supply.

Choose EPDM, FKM or FFKM diaphragms and matching O-rings for the actual reagent and cleaning fluid. Base-mounted and barbed versions use a PEEK base plate. Threaded versions offer additional valve-seat materials; PFA seat or base-plate configurations require a separate configuration check.

Typical Applications:

2-way solenoid valves for reagent on/off control, Power-off behavior: normally closed or normally open, Equipment integration: manifold or tubing connections

Model:This product is custom-made
Model familySV10-2
Valve structureRocker diaphragm valve
Ports and function2-way normally closed / 2-way normally open
ConnectionManifold mounting face; M6 / 1/4-28 UNF; Barbed; tubing ID 1.5–2.0 mm
SV10-PManifold mounting face. The PEEK base plate seals against the mating manifold. Match the port layout, locating holes and seals to the selected 2-way or 3-way version before designing the mounting face.
SV10-M6 / SV10-U28M6 / 1/4-28 UNF. Choose M6 or 1/4-28 UNF fittings to match the valve. Recommended thread engagement is 5 mm and tightening torque is 0.25–0.3 N·m. Use a suitable sealing washer at the bottom seal.
SV10-B16Barbed; tubing ID 1.5–2.0 mm. Use flexible tubing with an internal diameter of 1.5–2.0 mm, hardness of 55–65 Shore A and outer diameter below 4.5 mm. A custom mounting bracket is available for integration into the equipment.
Operating pressure-75 kPa – 0.25 MPa
Orifice diameter1.4 mm
Chamber volume20 μL
Flow coefficient Cv0.03
Diaphragm and O-ring optionsEPDM / FKM / FFKM
Base platePEEK; PFA for threaded versions by configuration
Threaded valve-seat optionsPVDF / PTFE / PMMA / POM / PEEK; PFA by configuration
Rated voltageDC 12 / 24 V (±10%)
Standard power2.5 W
Power-saving circuitStart: 2.5 W; hold: ≤1 W
Standard response time≤15 ms, no load
Power-saving response time≤25 ms, no load
Ambient temperature0–50 °C
Fluid temperature0–50 °C, non-freezing
Coil insulationF
WeightSV10-P: 30 g; SV10-M6 / SV10-U28: 39 g; SV10-B16: 29 g
Response test conditions25 °C, rated voltage, maximum operating pressure with air, common port pressurized. Response varies with fluid, pressure, tubing and temperature.

Typical Applications

FOREACH SV10 2-way miniature solenoid valves use a rocker diaphragm to open or close reagent and wash-fluid lines in automated equipment. Choose normally closed or normally open operation to match the required state without power.

2-way solenoid valves for reagent on/off control

In an automated analyzer, a 2-way valve can open the reagent line for a dispensing step and close it afterwards. Choose NC when the connection must be closed without power, or NO when it must remain open.

Coordinate the valve with the pump and equipment program. The valve controls the connection; the pump and its operating sequence determine the amount delivered.

Power-off behavior: normally closed or normally open

Use a normally closed version when the line must close without power, or normally open when it must remain open. Consider this state as part of the equipment shutdown and restart sequence.

Equipment integration: manifold or tubing connections

Use the base-mounted version when combining valves on a fluidic manifold. Choose threaded connections for tube fittings, or barbed connections for flexible tubing.

Plan access for installation, tubing replacement and wiring. The three connection styles serve different layouts while retaining the same choices of 2-way or 3-way function.

Tell us about your application

Describe which liquid must flow at each step and what should happen when power is removed. Include the connection drawing, fluids, pressure, temperature, supply voltage and installation space.

Compare 2-way and 3-way solenoid valves

All SV10 solenoid valves
3-Way Miniature Solenoid Valves

2D Drawing Not Available Yet

To request a 2D drawing for this product, please click “Add Drawing” above.

Datasheet not yet available

The datasheet for this product has not been uploaded yet.

Frequently Asked Questions

A normally closed valve closes the connection without power and opens it when energized. A normally open valve does the reverse. Coordinate the valve with the pump and control program: the valve controls the connection, while a pump or pressure difference moves the fluid.

Choose the valve according to what your equipment needs when power is removed. A normally closed solenoid valve closes the connection without power and opens it when energized. A normally open solenoid valve does the reverse. The SV10 series offers NC and NO options for its 2-way valves.

Provide the reagent and cleaning-fluid composition, concentration, temperature and contact time. Check all wetted parts together: diaphragm, O-rings, base plate and, on threaded versions, the valve seat. A material name alone does not establish compatibility with every fluid.

Yes. The SV10 series offers separate 12 V DC and 24 V DC versions, each with ±10% voltage tolerance. Select the coil for your equipment supply. Standard power is 2.5 W; the optional power-saving circuit uses 2.5 W at start and no more than 1 W while holding. Observe polarity: red positive, black negative.

Response is ≤15 ms for the standard version and ≤25 ms with the power-saving circuit under no-load test conditions at 25 °C, rated voltage and maximum operating air pressure applied to the common port. Actual timing varies with the circuit and fluid. FFKM diaphragms respond more slowly at temperatures of 15 °C or below.

Send the circuit diagram, 2-way or 3-way requirement, unpowered state, connection type, reagent and cleaning fluids, pressure, temperature and supply voltage. Include mounting space and cycle timing so we can match the connection, materials and power-saving option.