FOREACH Miniature Solenoid Valve with M6 or 1/4-28 UNF Ports
FOREACH SV10-M6 and SV10-U28 are miniature diaphragm solenoid valves with threaded ports for tube fittings. These SV10 series valves offer 2-way normally closed, 2-way normally open and 3-way versions for opening reagent lines or switching between reagent and wash fluid.
The rocker diaphragm opens or closes a connection in a 2-way solenoid valve, or switches the common port between the other two ports in a 3-way solenoid valve. Choose a normally closed or normally open 2-way version for the required state without power. A pump or pressure difference moves the fluid; the valve controls its path. Select a 12 V DC or 24 V DC coil to match the equipment supply.
Choose EPDM, FKM or FFKM diaphragms and matching O-rings for the actual reagent and cleaning fluid. Base-mounted and barbed versions use a PEEK base plate. Threaded versions offer additional valve-seat materials; PFA seat or base-plate configurations require a separate configuration check.
Choose M6 or 1/4-28 UNF fittings to match the valve. Recommended thread engagement is 5 mm and tightening torque is 0.25–0.3 N·m. Use a suitable sealing washer at the bottom seal.
Typical Applications:
2-way solenoid valves for reagent on/off control, 3-way solenoid valves for reagent and wash-fluid switching, Equipment integration: manifold or tubing connections
| Model family | SV10-M6 / SV10-U28 |
|---|---|
| Valve structure | Rocker diaphragm valve |
| Ports and function | 2-way NC / 2-way NO / 3-way universal |
| Connection | M6 / 1/4-28 UNF |
| Operating pressure | -75 kPa – 0.25 MPa |
| Orifice diameter | 1.4 mm |
| Chamber volume | 20 μL |
| Flow coefficient Cv | 0.03 |
| Diaphragm and O-ring options | EPDM / FKM / FFKM |
| Base plate | PEEK; PFA for threaded versions by configuration |
| Threaded valve-seat options | PVDF / PTFE / PMMA / POM / PEEK; PFA by configuration |
| Rated voltage | DC 12 / 24 V (±10%) |
| Standard power | 2.5 W |
| Power-saving circuit | Start: 2.5 W; hold: ≤1 W |
| Standard response time | ≤15 ms, no load |
| Power-saving response time | ≤25 ms, no load |
| Ambient temperature | 0–50 °C |
| Fluid temperature | 0–50 °C, non-freezing |
| Coil insulation | F |
| Weight | 39 g |
| Response test conditions | 25 °C, rated voltage, maximum operating pressure with air, common port pressurized. Response varies with fluid, pressure, tubing and temperature. |
Typical Applications
Use a 2-way solenoid valve to open or close a reagent line, or a 3-way solenoid valve to switch a common line between two fluid connections. Match the SV10 connection style to your manifold, tube fittings or flexible tubing.
2-way solenoid valves for reagent on/off control
In an automated analyzer, a 2-way valve can open the reagent line for a dispensing step and close it afterwards. Choose NC when the connection must be closed without power, or NO when it must remain open.
Coordinate the valve with the pump and equipment program. The valve controls the connection; the pump and its operating sequence determine the amount delivered.
3-way solenoid valves for reagent and wash-fluid switching
A 3-way valve can connect a common line alternately to reagent and cleaning fluid. After the reagent step, switch to the wash connection and use the pump to flush the shared tubing.
Set wash volume and repetitions according to the fluids, tubing length and acceptable residue, and check the result using the actual cleaning cycle.
Equipment integration: manifold or tubing connections
Use the base-mounted version when combining valves on a fluidic manifold. Choose threaded connections for tube fittings, or barbed connections for flexible tubing.
Plan access for installation, tubing replacement and wiring. The three connection styles serve different layouts while retaining the same choices of 2-way or 3-way function.
Tell us about your application
Describe which liquid must flow at each step and what should happen when power is removed. Include the connection drawing, fluids, pressure, temperature, supply voltage and installation space.
Compare 2-way and 3-way solenoid valves
2D Drawing Not Available Yet
To request a 2D drawing for this product, please click “Add Drawing” above.
Datasheet not yet available
The datasheet for this product has not been uploaded yet.
Frequently Asked Questions
A 2-way solenoid valve opens or closes one connection. A 3-way solenoid valve switches a common connection between two other ports, for example reagent and wash fluid. The SV10 series offers both functions in manifold-mounted, threaded and barbed versions.
Configure your SV10 solenoid valve
Match the valve function, connection, wetted materials and voltage to your equipment.