Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Environmental monitoring/Industrial wastewater monitoring
< Back

Fluidic valves in industrial wastewater monitoring

Application guide

Explore fluidic-valve placement, coordination and configuration for analytical sample supply, maintenance routing and flushing or backflush shutoff, with links to wastewater-monitoring operating and validation tasks.

Applicable architecture

Define target components according to the analytical method first. EPA Method 200.8, for example, specifies different sample treatments for dissolved and total recoverable elements. Filtration should therefore follow the analytical target; one treatment cannot be generalized to all wastewater monitoring.[3]

Application guides

Industrial wastewater monitoring application guide

Fluidic Overview for Industrial Wastewater Monitoring
Diaphragm pumps in industrial wastewater monitoring
Complex water-sample transferDrainage and backflushing
Fluidic valves in industrial wastewater monitoring
Bubble and pressure detection in industrial wastewater monitoring
Connections and protection in industrial wastewater monitoring
Filter maintenance

ON THIS PAGE

What do these products do in this instrument?Define connections using the instrument's port-state diagramInclude renewal of shared segments after switching in the sequenceTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageConfirm product roles in actual operationDo more valve ports mean more channels can supply liquid simultaneously?ReferencesRelated guides

01What do these products do in this instrument?

Multiport rotary valves: analytical supply and maintenance routing

Connect the current sample, wash liquid or maintenance outlet in selector-valve wastewater paths, coordinated with drives and analytical states. After backflushing or bypass operation, confirm sealing and fresh-sample replacement.

MRV3 selects sources or destinations and requires a port-state diagram and shared-volume budget. Port count indicates routing options; confirm pressure in each state and independent simultaneous supply requirements separately.

Solenoid valves: flushing and backflush branch shutoff

Open or close maintenance branches in applicable on-off configurations, coordinated with pumps and drainage destinations. Define flow direction, differential pressure and unpowered states, with interlocks to prevent maintenance liquid reaching the analytical interface.

Solenoid valves control branches according to actual ports, flow direction, differential pressure and power-off state. Check opening/closing order with pump commands; inspect shutoff leakage and shared residue separately.

02Define connections using the instrument's port-state diagram

This page covers multiport rotary and solenoid valves. Mark each port, current source, receiver and isolated branch, checking connections during aspiration, delivery, cleaning, maintenance and power loss. Valve selection must match conditions permitting drive actions.

03Include renewal of shared segments after switching in the sequence

After source switching, shared tubing may retain the previous composition. Record volume and arrival delay from the new source to the receiver, and measure residue and recovery for the actual worst-case switching combination. Confirm port positioning and arrival of new liquid separately.

04Translate actual branch conditions into configuration requirements

Fluidic-valve configuration for industrial wastewater monitoring
ConditionTo confirm
Connections and pressureProvide port diagrams and pressure conditions for all operating, cleaning and shutdown states.
Shared volumeIdentify residue locations after source changes, flushing volumes and discharge destinations.
Control and isolationCheck valve-position feedback, pump actions, shutoff leakage and permitted power-off states.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
MRV3 multiport rotary valveMultiple-source selectionCompare 10-, 16- and 24-port options and port diagrams; verify high-pressure suitability separately
SV10 solenoid valveOn/off control or branch selectionCheck normal state, differential pressure, flow direction and duty cycle; high-pressure tasks require a separately suitable configuration
  • MRV3 multiport rotary valve
  • SV10 solenoid valve

06Confirm product roles in actual operation

Validate delivered-sample representativeness, target recovery and renewal after washing and restart.

07Do more valve ports mean more channels can supply liquid simultaneously?

Check port connection structure and drive configuration. The number of selectable sources, independent paths and simultaneous-operation capability are different conditions, determined by actual connections in each state.

Water-test specifications do not establish suitability for complex wastewater. Filtration must follow the defined target fraction.

References

View references (3)
  1. [1]FOREACH MRV3 multiport rotary valve: configurations and specifications
  2. [2]FOREACH SV10 solenoid valve: configurations and specifications
  3. [3]EPA Method 200.8: Collection, Preservation and Preparation for Elemental Analysis of Water and Wastewater

Related guides

  • Return to the industrial wastewater monitoring overview

Related Products

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

SV10 solenoid valve; representative configuration. Select capacity, materials and interfaces for the application.

SV10 solenoid valve

Related Technical Articles

Rotary Valve Selection Guide: From Fluid Paths to System Validation

Map the connections required at each step before comparing specifications. Use the actual liquids, tubing and switching sequence to validate suitability for your instrument.

2026-09-30View Details

How Does a 6-Port HPLC Injection Valve Work? Load, Inject and Vent

Follow sample loading into an external loop and transfer to the column by the mobile phase, distinguishing the HP valve's main positions and vent path from the factors that determine injection volume.

2026-09-29View Details

How to Read a Diaphragm Pump Flow-Pressure Curve—and Predict Installed Flow

A catalogue value such as 300 or 600 mL/min is not a fixed flow rate inside an instrument. The useful engineering question is: at the actual inlet pressure, outlet backpressure, fluid, tubing and supply voltage, where will the pump and the fluidic circuit settle?

2026-07-28View Details

Discuss fluidic configurations for industrial wastewater monitoring

Provide a fluidic diagram, actual liquids and pressures in each operating state. Compare 10-, 16- and 24-port options using port diagrams, and verify high-pressure suitability separately. Check normal state, differential pressure, flow direction and energization cycle. Select a separately suitable configuration for high-pressure tasks. Assess configurations against this guide's validation objectives.

Contact an engineer