Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Tubing Assemblies/Ferrule Tubing Assemblies/PFA Ferrule Tubing Assembly
Ferrule tubing assembly with black tubing, a black fitting and tube-end sealing components

PFA Ferrule Tubing Assembly

FOREACH PFA ferrule tubing assemblies combine PFA tubing, matching fittings and ferrules. The compressed ferrule connects the instrument port without pre-flanging the tube end. They can connect reagent, cleaning-fluid and internal fluid paths in in-vitro diagnostic (IVD) and automated analytical instruments. Reference tubing OD is 1.6 mm, with IDs of 0.5, 0.8 or 1.0 mm. Specify length and both end connections in the drawing.

Standard flat-bottom port threads include M6×1 and 1/4-28 UNF. Select fitting materials and PP or ETFE ferrules for the model, tube size and operating conditions, confirming compatibility among tubing, ferrule and port. Define A/B fitting structures, threads and materials separately and specify stop tubes and identification as needed. Samples and batch assembly are supported. Confirm working pressure and temperature for the specific dimensions, ports and complete assembly.

FOREACH holds ISO 9001 and ISO 13485 quality management system certifications.

Typical Applications:

PFA reagent line connections, End connections for 1.6 mm OD tubing, Fluid connections without pre-flanging, Instrument tubing assembly

Model:This product is custom-made

Assembly Parameters

Tubing material and appearancePFA
Connection structureFerrule connection; no tube pre-flanging required
Fitting structureStandard, compact
Fitting materialPPS, PVDF, PEEK, POM, PP; selected by series
Thread sizesM6×1、1/4-28 UNF
Ferrule materialPP, ETFE; matched to the model
Finished lengthCustom to drawing, with specified length and tolerance
A/B endsFitting material, thread and connection type can be specified separately
Optional configurationsStop tubes, heat-shrink labels

Tube Size Combinations

PFA
Tube OD (mm)Matching Tube ID (mm)
1.60.5 / 0.8 / 1.0

These are available tubing sizes. Confirm end dimensions and mating ports against the assembly drawing.

Match fitting material, structure and thread to the corresponding model.

Working pressure and temperature must be confirmed for the specific assembly configuration.

PFA Ferrule Tubing Applications & Customization

Equipment development, assembly to drawing, sample development and batch production are supported.

Instrument fluid-path integration

Assemblies for in-vitro diagnostic and automated analytical instruments are selected against the actual reagent, cleaning fluid and connection requirements.

PFA tubing and custom ends

PFA tubing can be configured for the required length and end connections. Confirm tube-end forming and sealing components against the selected size and mating port.

Assembly drawings and dimensions

Provide tube ID/OD, finished length and tolerance, length measurement datum, A/B port drawings, fitting materials, threads and installation space. Show stop and label positions and dimensions on the assembly drawing.

Fluids, pressure and temperature

Specify the working fluid, concentration, cleaning fluid, contact time, pressure, temperature and inspection requirements to confirm wetted materials and the complete assembly.

Installation and mating ports

Check ferrule orientation, tube insertion depth and fitting tightening requirements. Assemble to the drawing and specified torque; avoid tension and sharp bends.

Quality documents and delivery

FOREACH holds ISO 9001 and ISO 13485 quality management system certifications. Applicable REACH and RoHS reports and material safety data sheets (MSDS) can be supplied for relevant connection components according to material and model. Dimensional inspection, seal testing, identification and packaging requirements for samples and batches are agreed for each project.

Submit your requirements

Prepare an assembly drawing, port drawing or BOM, together with sample quantity, batch requirements and acceptance criteria.

Use the fluid resistance calculator for preliminary estimates when comparing how tube diameter or length affects pressure drop.

Estimate fluid resistance
No public 3D model is available for this custom tubing assembly. Contact us to confirm the required configuration.

2D Drawing Not Available Yet

To request a 2D drawing for this product, please click “Add Drawing” above.

Frequently Asked Questions

The currently listed reference OD is 1.6 mm, with 0.5, 0.8 or 1.0 mm ID. For other sizes, provide a drawing so an engineer can review tubing availability and end connections.

Specify finished length and tolerance, A/B fittings and threads, and the positions of stop tubes and identification to suit the routing. Connection components are matched to the tube dimensions and ports.

No. The matching fitting compresses the ferrule to retain and seal the tubing. Follow the model-specific requirements for ferrule orientation, tube insertion depth and tightening.

Pressure depends on tubing, dimensions, temperature, connections and assembly. Provide the target pressure and fluid; use the confirmed rating and test report for that configuration.

Submit your requirements

Prepare an assembly drawing, port drawing or BOM, together with sample quantity, batch requirements and acceptance criteria.

Customization Request