Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Tubing Assemblies/Retaining-Ring Tubing Assemblies/PFA Retaining-Ring Tubing Assembly
PFA retaining-ring tubing assembly with transparent tubing, a beige threaded fitting, a metal retaining ring and a sealing washer

PFA Retaining-Ring Tubing Assembly

FOREACH PFA retaining-ring tubing assemblies combine PFA tubing, matching threaded fittings, retaining sleeves and sealing washers for reagent, cleaning-fluid and internal connections in in-vitro diagnostic (IVD) and automated analytical instruments. Reference tubing OD is 1.6 mm, with IDs of 0.5, 0.8 or 1.0 mm. Specify finished length and A/B end connections in the assembly drawing.

Select a PEEK 6-40 UNF miniature fitting or HSF6 configuration with M6×1 or 1/4-28 UNF threads to suit the port. Match the sleeve and sealing washer to the selected tube size, material and fitting model. Show positions and dimensions for protective sleeves, stop tubes, heat-shrink labels or coils in the drawing. Samples, equipment development and batch assembly are supported. Confirm working pressure and temperature for the specific dimensions, ports and complete assembly.

FOREACH holds ISO 9001 and ISO 13485 quality management system certifications.

Typical Applications:

PFA reagent line connections, End connections for 1.6 mm OD tubing, Custom retaining-ring tubing, Internal instrument fluid connections

Model:This product is custom-made

Assembly Parameters

Tubing material and appearancePFA
Connection structureRetaining sleeve and sealing washer
Matching fittingsHSF6 fittings, 6-40 UNF miniature fittings
Fitting materialPPS, PEEK; selected by series
Standard threadsM6×1, 1/4-28 UNF (HSF6 configuration)
Retaining-ring kitSUS and PEEK components matched to the kit model
Finished lengthCustom to drawing, with specified length and tolerance
A/B endsFitting material, thread and connection type can be specified separately
Optional configurationsCoils, abrasion protection sleeves, stop tubes, heat-shrink labels

Tube Size Combinations

PFA
Tube OD (mm)Matching Tube ID (mm)
1.60.5 / 0.8 / 1.0

These are available tubing sizes. Confirm end dimensions and mating ports against the assembly drawing.

Match fitting material, structure and thread to the corresponding model.

Miniature option: 6-40 UNF, PEEK fitting, 1.6 mm tube OD. Confirm the complete end configuration against the selected model.

Working pressure and temperature must be confirmed for the specific assembly configuration.

PFA Retaining-Ring Tubing Applications & Customization

Equipment development, assembly to drawing, sample development and batch production are supported.

Instrument fluid-path integration

Assemblies for in-vitro diagnostic and automated analytical instruments are selected against the actual reagent, cleaning fluid and connection requirements.

PFA tubing and custom ends

PFA tubing can be configured for the required length and end connections. Confirm tube-end forming and sealing components against the selected size and mating port.

Assembly drawings and dimensions

Provide tube ID/OD, finished length and tolerance, length measurement datum, A/B port drawings, fitting materials, threads and installation space. Show coil, sleeve, stop and label positions and dimensions on the assembly drawing.

Fluids, pressure and temperature

Specify the working fluid, concentration, cleaning fluid, contact time, pressure, temperature and inspection requirements to confirm wetted materials and the complete assembly.

Installation and mating ports

Install the sleeve and sealing washer in the specified sequence and orientation using the designated tools. Confirm tube OD, retaining-ring kit and port as a matched connection.

Quality documents and delivery

FOREACH holds ISO 9001 and ISO 13485 quality management system certifications. Applicable REACH and RoHS reports and material safety data sheets (MSDS) can be supplied for relevant connection components according to material and model. Dimensional inspection, seal testing, identification and packaging requirements for samples and batches are agreed for each project.

Submit your requirements

Prepare an assembly drawing, port drawing or BOM, together with sample quantity, batch requirements and acceptance criteria.

Use the fluid resistance calculator for preliminary estimates when comparing how tube diameter or length affects pressure drop.

Estimate fluid resistance
No public 3D model is available for this custom tubing assembly. Contact us to confirm the required configuration.

2D Drawing Not Available Yet

To request a 2D drawing for this product, please click “Add Drawing” above.

Frequently Asked Questions

The currently listed reference OD is 1.6 mm, with 0.5, 0.8 or 1.0 mm ID. For other sizes, provide a drawing so an engineer can review tubing availability and end connections.

Specify finished length and tolerance, A/B fittings and threads, and the positions of sleeving, stop tubes and identification to suit the routing. Connection components are matched to the tube dimensions and ports.

6-40 UNF uses a PEEK fitting for 1.6 mm OD tubing. HSF6 offers M6×1 or 1/4-28 UNF. Match the port thread and tube OD to the specification table.

Pressure depends on tubing, dimensions, temperature, connections and assembly. Provide the target pressure and fluid; use the confirmed rating and test report for that configuration.

Related Technical Articles

What Is a Compression-Ring Fitting? Design, Sizes and Selection

A compression-ring fitting combines a threaded nut, a compression ring and a sealing ferrule without requiring a preformed tubing flange. Using FOREACH HSF6 and CL-1S as examples, this guide covers M6×1 and 1/4-28 UNF ports, tubing ODs from 1.6 to 3.2 mm, PPS/PEEK nuts, stainless-steel rings and PEEK ferrules, together with prefabrication, installation and reconnection.

2026-10-13View Details

Microfluidic Hard-Tube Fitting Selection Guide: Flanged, Ferrule and Snap-Ring Connections

Selection essentials: Check port geometry, tubing OD and fluid first, then pressure, maintenance frequency and tube-end preparation. Flanged fittings press a tube-end flange against a flat sealing face; ferrules grip the tube as the fitting tightens; snap-ring designs use a sleeve and sealing ring. Matching threads and tube diameters alone do not establish compatibility.

2026-10-12View Details

Submit your requirements

Prepare an assembly drawing, port drawing or BOM, together with sample quantity, batch requirements and acceptance criteria.

Customization Request