Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Environmental monitoring/Online monitoring integration
< Back

Bubble and pressure detection in online monitoring integration

Application guide

Explore sensing locations, coordination and configuration for controller linkage between fluid anomalies and data status in online monitoring, with links to operating and validation tasks.

Application guides

Online Monitoring Integration Guide

Online monitoring integration fluidics overview
Diaphragm pumps in online monitoring integration
Fluidic Valves for Online Monitoring Integration
Path management
Bubble and pressure detection in online monitoring integration
Fluidic Connections and Protection for Online Monitoring Integration

ON THIS PAGE

What do these products do in this instrument?Match sensing locations to specific fluidic problemsConnect signals, action windows and recovery conditionsTranslate actual branch conditions into configuration requirementsMonitoring and recoveryCompare product configurations by the roles on this pageConfirm product roles in actual operationCan dispensing be repeated immediately after bubbles or abnormal pressure are detected?ReferencesRelated guides

01What do these products do in this instrument?

Bubble and pressure sensing: signals for fluidic and data-state assessment

Provide bubble and pressure signals at defined liquid-path locations. Interpret faults with source, valve-position and maintenance-stage information. Actual path restoration and method checks determine release of the first valid measurement.

ABD provides bubble or liquid-state signals for defined tubing; PDM5 provides pressure information at a defined location. Configure module, position and action window separately; the controller associates affected samples or tasks.

02Match sensing locations to specific fluidic problems

Bubble modules report bubble or liquid state in defined tube segments; pressure modules report pressure at defined positions. Before selecting mounting points, define the phase and abnormality to observe: aspiration, delivery, source depletion or branch-load changes. Associate sensor positions with affected samples, cuvettes or stations.

03Connect signals, action windows and recovery conditions

The same signal may mean different things at different valve positions or operating phases. Record normal ranges and faults with actual liquids, tubing and sequences. The controller combines action timing, confirmed delivery status, volume records and sample identity to pause, review or recover; one pressure change cannot directly identify a blockage location or specific cause. Distinguish measured, estimated and unknown volumes; completion of a command does not prove actual liquid delivery.

04Translate actual branch conditions into configuration requirements

Bubble and pressure detection configuration requirements for online monitoring integration
ConditionTo confirm
Installation conditionsSpecify tubing dimensions, liquid, sensing location and branch to observe.
Timing and baselineRecord valve positions, pump actions, normal changes and fault-detection windows.
Abnormality handlingAssociate affected containers with confirmed delivery status and volume records; define conditions for review, continuation or re-execution. Distinguish measured, estimated and unknown volumes; completion of a command does not prove actual liquid delivery.
Operations supported in this instrument
OperationSpecific operating conditions
Monitoring and recoverySpecific sensor configuration, location, liquid/tubing, sampling rate, threshold and time window

05Monitoring and recovery

Define stop-measurement, alarm and recovery logic for empty sources, blockage, leakage, full waste vessels and communication faults. Use trends and actual sample restoration to determine data validity; one normal sensor signal is insufficient.

Define separate stop-measurement conditions for empty sources, blockage, leaks, full waste containers and communication faults. Verify actual recovery after an alarm clears before accepting valid measurements.

Measure fault detection, false alarms and end-to-end response separately; cover baseline changes with liquid, speed and operating conditions

Normal air segments, viscosity changes and sampling delays may be misclassified. The controller determines task validity; sensors alone do not prove dose or assay results.

06Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
ABD bubble-detection moduleBubble or liquid-state identification in defined tubingValidate detection and false alarms for tubing material, dimensions, medium and action window
PDM5 pressure-detection modulePressure-state monitoring at a defined fluidic locationConfirm range and wetted configuration by model; validate normal baseline and abnormalities separately
  • ABD bubble-detection module
  • PDM5 pressure-detection module

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Monitoring and recoveryMeasure fault detection, false alarms and end-to-end response separately; cover baseline changes with liquid, speed and operating conditionsNormal air segments, viscosity changes and sampling delays may be misclassified

Cover extended operation, maintenance, power loss, empty sources and blockage recovery, including data flags.

08Can dispensing be repeated immediately after bubbles or abnormal pressure are detected?

First establish whether partial delivery has occurred and which container is affected. Immediate repetition may double-dose it. Act on the actual state and recheck the first cycle after recovery.

Validate field service life and maintenance intervals under actual conditions; motor life or free-flow ratings alone are insufficient.

References

View references (2)
  1. [1]FOREACH ABD bubble-detection module: configurations and specifications
  2. [2]FOREACH PDM5 pressure-detection module: configurations and specifications

Related guides

  • Back to the online monitoring integration fluidics overview

Related Products

ABD bubble-detection module; representative configuration. Select capacity, materials and interfaces for the application.

ABD bubble-detection module

PDM5 pressure-detection module; representative configuration. Select capacity, materials and interfaces for the application.

PDM5 pressure-detection module

Related Technical Articles

Why Do Air Bubbles Delay or Bias Piston Pump Dispensing?

A completed piston stroke does not prove that the intended liquid volume reached the vessel. Bubble compression temporarily stores displacement; expansion can then cause a trailing dispense or affect the next cycle. Locate where bubbles first appear and compare synchronized pressure and individual dispense masses before and after priming.

2026-09-10View Details

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Rotary Valve Selection Guide: From Fluid Paths to System Validation

Map the connections required at each step before comparing specifications. Use the actual liquids, tubing and switching sequence to validate suitability for your instrument.

2026-09-30View Details

Discuss an online monitoring fluidic configuration

Provide a fluid-path diagram, actual liquids and pressures in each state. Validate detection and false alarms for the tubing, dimensions, media and action window. Confirm range and wetted configuration by model, then test normal baselines and faults separately against the guide's validation objectives.

Contact an engineer