Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Environmental monitoring/Online monitoring integration
< Back

Fluidic Connections and Protection for Online Monitoring Integration

Application guide

This page explains tubing connection and protection locations, coordination and configuration requirements for method-permitted sampling protection, cabinet interior/exterior connections and maintenance access in online monitoring integration, with links to relevant operating and validation tasks.

Application guides

Online Monitoring Integration Guide

Online monitoring integration fluidics overview
Diaphragm pumps in online monitoring integration
Fluidic Valves for Online Monitoring Integration
Path management
Bubble and pressure detection in online monitoring integration
Fluidic Connections and Protection for Online Monitoring Integration

ON THIS PAGE

What do these products do in this instrument?Design tubing and fittings as a complete wetted pathCheck analyte retention while protecting componentsTranslate actual branch conditions into configuration requirementsIn-cabinet connectionsCompare product configurations by the roles on this pageConfirm product roles in actual operationDoes a fitting that tightens prove the tubing assembly is suitable?ReferencesRelated guides

01What do these products do in this instrument?

Filters: Method-Permitted Sampling Protection

Mark permitted protective locations on whole-cabinet drawings, selecting configurations for target components and maintenance bypasses. Include pressure-drop changes, consumable replacement and analyte deviations in maintenance and data records.

Filters provide method-permitted particle retention or component protection. Target components, pore size and filter material guide selection. Assess pressure drop, adsorption and recovery after replacement in the actual path.

Tubing and fittings: cabinet interior/exterior connections and maintenance access

Form actual sampling, pretreatment, analytical and waste paths, marking flow direction and removable sections. Assess connections under field temperature, condensation or cold conditions. Revalidate sample refresh after maintenance.

Tubing and fittings together form sealed connections and the actual transfer path. Check formulation, inner/outer diameters, length, tube-end positioning and port geometry, including added volume in residue and arrival delay.

02Design tubing and fittings as a complete wetted path

Tubing, fittings and ports jointly determine sealing, transfer volume and medium-contact coverage. Materials and dimensions must suit formulation, operating conditions and installation. Include tubing length and interface volume in priming, shared residue and arrival delay. After connection changes, recheck delivery and cleaning through the actual path.

03Check analyte retention while protecting components

Filters provide method-permitted particle retention or component protection. With actual samples and filter materials, check adsorption, blanks, pressure drop and flow changes as loading accumulates, while measuring analyte recovery. The specific method must validate whether the filtrate remains suitable for analysis.

04Translate actual branch conditions into configuration requirements

Connection and protection configuration for online monitoring integration
ConditionTo confirm
Materials and assemblyProvide formulation, tubing inner/outer diameters, length, fitting structure and port fit.
Volume and loadCalculate shared and replacement-component added volumes; measure actual flow and response.
Filtration and method requirementsConfirm filter material and pore size. Compare analyte recovery, blanks and pressure drop before and after fouling, and record recovery after replacement.
Operations supported in this instrument
OperationSpecific operating conditions
In-cabinet connectionsTubing ID/OD, length, interface geometry, pressure, materials and maintenance method

05In-cabinet connections

Confirm cabinet temperature, tubing layout, labels, sealing and maintenance access. Assess condensation or low-temperature effects for the project environment. After disassembly, recheck connections and sample renewal.

Make connections easy to identify, disassemble and inspect for sealing. Evaluate temperature, condensation and cold-weather effects for the project environment. Revalidate sample renewal after replacement.

Check leaks, tube disconnection and material changes at actual pressure and temperature; evaluate residue, recovery and the first post-maintenance cycle through the complete path

Misconnections, gaps, tube deformation or leaks may alter volume and pressure. Isolate the affected segment and reconfirm assembly; matching threads do not establish interchangeability.

06Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
PE-Series FiltersParticle retention permitted by the methodCards show representative configurations. Select actual pore size and filter material for the target, pressure drop and recovery requirements.
Tubing materials and dimensionsConnection paths and shared volumeBore, length, load and actual formulation jointly determine materials and dimensions
Rigid-tubing fittingsTube-end positioning and sealed connectionsCheck tube outer diameter, threads, seal structure and port-bottom geometry
  • PE-Series Filters
  • Tubing materials and dimensions
  • Rigid-tubing fittings

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
In-cabinet connectionsCheck leaks, tube disconnection and material changes at actual pressure and temperature; evaluate residue, recovery and the first post-maintenance cycle through the complete pathMisconnections, gaps, tube deformation or leaks may alter volume and pressure

Cover extended operation, maintenance, power loss, empty sources and blockage recovery, including data flags.

08Does a fitting that tightens prove the tubing assembly is suitable?

Also confirm port geometry, tube-end positioning and seal fit. Check leakage, hold-up and performance after repeated maintenance under actual conditions; thread engagement alone is insufficient.

Validate field service life and maintenance intervals under actual conditions; motor life or free-flow ratings alone are insufficient.

References

View references (3)
  1. [1]FOREACH PE series filters: configurations and specifications
  2. [2]FOREACH tubing materials and dimensions: configurations and specifications
  3. [3]FOREACH rigid-tubing fittings: configurations and specifications

Related guides

  • Back to the online monitoring integration fluidics overview

Related Products

PE-Series Filters; representative configuration. Select capacity, materials and interfaces for the application.

PE-Series Filters

Tubing materials and dimensions; representative configuration. Select capacity, materials and interfaces for the application.

Tubing materials and dimensions

Rigid-tubing fittings; representative configuration. Select capacity, materials and interfaces for the application.

Rigid-tubing fittings

Related Technical Articles

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Why Does Actual Flow Change So Much When the Tubing Size Changes on the Same Miniature Diaphragm Pump?

Even when the pump is unchanged, installed flow can change because of tubing inner diameter, length, bends, and the minimum bore of fittings. When flow falls after a tubing change, the effective response is neither to blame the pump first nor to enlarge every tube indiscriminately. Measure inlet pressure, outlet pressure, and accumulated flow together to determine where the added restriction actually occurs.

2026-08-24View Details

Rotary Valve Selection Guide: From Fluid Paths to System Validation

Map the connections required at each step before comparing specifications. Use the actual liquids, tubing and switching sequence to validate suitability for your instrument.

2026-09-30View Details

Discuss an online monitoring fluidic configuration

Provide a fluidic diagram, actual liquids and pressures in each operating state. Cards show representative configurations; choose actual pore size and filter material for the analyte, pressure drop and recovery. Select tubing material and dimensions using bore, length, load and formulation. Check OD, threads, sealing structure and port-bottom geometry. Compare configurations against this guide's validation objectives.

Contact an engineer