Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Analytical instruments/Analytical system integration
< Back

Fluidic Valves for Analytical System Integration

Application guide

Explore fluidic-valve placement, coordination and configuration for sample, standard and wash-source selection, branch shutoff and maintenance isolation, with links to analytical-system operating and validation tasks.

Application guides

Analytical system integration application guide

Analytical system integration fluidics overview
Piston Pumps for Analytical System Integration
Syringe pumps in analytical system integration
Valveless metering pumps in analytical system integration
Diaphragm pumps in analytical system integration
Fluidic Valves for Analytical System Integration
Ports and interlocks
Bubble and pressure sensing in analytical system integration
Tubing and Fittings for Analytical System Integration

ON THIS PAGE

What do these products do in this instrument?Define connections using the instrument's port-state diagramInclude renewal of shared segments after switching in the sequenceTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageExplore specific operating and validation tasksConfirm product roles in actual operationDo more valve ports mean more channels can supply liquid simultaneously?ReferencesRelated guides

01What do these products do in this instrument?

Multiport rotary valves: selection of sample, standard and wash sources

Establish the current analytical or maintenance connection in fixed paths with multiple sources, coordinated with drives and measurement windows. Correct valve position still requires confirmation of new-liquid arrival and residue clearance.

MRV3 selects sources or destinations and requires a port-state diagram and shared-volume budget. Port count indicates routing options; confirm pressure in each state and independent simultaneous supply requirements separately.

Solenoid Valves: Branch On-Off Control and Maintenance Isolation

Control opening, closing or two-way switching in actual branches, coordinated with pump and bypass programs. Identify destinations and permitted pressures for normal, power-loss and fault states separately.

Solenoid valves control branches according to actual ports, flow direction, differential pressure and power-off state. Check opening/closing order with pump commands; inspect shutoff leakage and shared residue separately.

02Define connections using the instrument's port-state diagram

This page covers multiport rotary and solenoid valves. Mark each port, current source, receiver and isolated branch, checking connections during aspiration, delivery, cleaning, maintenance and power loss. Valve selection must match conditions permitting drive actions.

03Include renewal of shared segments after switching in the sequence

After source switching, shared tubing may retain the previous composition. Record volume and arrival delay from the new source to the receiver, and measure residue and recovery for the actual worst-case switching combination. Confirm port positioning and arrival of new liquid separately.

04Translate actual branch conditions into configuration requirements

Fluidic Valve Configuration for Analytical System Integration
ConditionTo confirm
Connections and pressureProvide port diagrams and pressure conditions for all operating, cleaning and shutdown states.
Shared volumeIdentify residue locations after source changes, flushing volumes and discharge destinations.
Control and isolationCheck valve-position feedback, pump actions, shutoff leakage and permitted power-off states.
Operations supported in this instrument
OperationSpecific operating conditions
Ports and interlocksTask state, sample or vessel identity, concurrent resources, interlocks and restart

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
MRV3 multiport rotary valveMultiple-source selectionCompare 10-, 16- and 24-port options and port diagrams; verify high-pressure suitability separately
SV10 solenoid valveOn/off control or branch selectionCheck normal state, differential pressure, flow direction and duty cycle; high-pressure tasks require a separately suitable configuration
  • MRV3 multiport rotary valve
  • SV10 solenoid valve

06Explore specific operating and validation tasks

Ports and interlocks

Include measurement, washing, bypass and fault states in the drawings. Shared volume and transport delay determine when a signal can be identified as a valid sample measurement.

  • Ports and interlocks

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Ports and interlocksTest concurrent operation, limiting states and complete fault recovery; verify that identities, cumulative quantities and records match actual actionsResource conflicts, communication loss or mismatched identities can cause delivery to the wrong destination or repeated dosing.

Check delivery, response, blanks and fault recovery through the complete method cycle.

08Do more valve ports mean more channels can supply liquid simultaneously?

Check port connection structure and drive configuration. The number of selectable sources, independent paths and simultaneous-operation capability are different conditions, determined by actual connections in each state.

Configure metering, continuous supply, liquid washing and air-containing waste removal separately. See Laboratory Automation for platform scheduling.

References

View references (2)
  1. [1]FOREACH MRV3 multiport rotary valve: configurations and specifications
  2. [2]FOREACH SV10 solenoid valve: configurations and specifications

Related guides

  • Back to analytical system integration fluidics
  • Ports and interlocks

Related Products

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

SV10 solenoid valve; representative configuration. Select capacity, materials and interfaces for the application.

SV10 solenoid valve

Related Technical Articles

Rotary Valve Selection Guide: From Fluid Paths to System Validation

Map the connections required at each step before comparing specifications. Use the actual liquids, tubing and switching sequence to validate suitability for your instrument.

2026-09-30View Details

How Does a 6-Port HPLC Injection Valve Work? Load, Inject and Vent

Follow sample loading into an external loop and transfer to the column by the mobile phase, distinguishing the HP valve's main positions and vent path from the factors that determine injection volume.

2026-09-29View Details

Piston Pump Accuracy, Repeatability and Resolution Explained

Learn why theoretical volume per step is not the minimum reliable dose, and how accuracy, repeatability, valves, bubbles and working stroke affect dispensing results.

2026-09-06View Details

Discuss fluidic configurations for analytical system integration

Provide a fluidic diagram, actual liquids and pressures in each operating state. Compare 10-, 16- and 24-port options using port diagrams, and verify high-pressure suitability separately. Check normal state, differential pressure, flow direction and energization cycle. Select a separately suitable configuration for high-pressure tasks. Assess configurations against this guide's validation objectives.

Contact an engineer