Following one cleaning cycle through the cap, suction line and waste container
On a system that applies suction at the cap, first check whether the prescribed cleaning fluid reaches the cap on schedule, then whether liquid can be drawn out, and finally how much reaches the waste container. Mimaki distinguishes cleaning nozzles in the cap from cleaning the drain line below it. If the printer has a separate positive-pressure purge, use the fluid, pressure and duration specified in the head and machine manuals.[5][4][2]
Map the valve positions used for cleaning-fluid switching and branch isolation. Mark sections exposed only to cleaning fluid and those exposed to ink and waste. If a nozzle check shows dropouts and no fluid reaches the cap, start with the inlet and valve positions. If fluid is present but cannot drain, check the cap seal, drain line below the cap and waste-container inlet in sequence.[4][3]
How to verify drainage and print recovery in one maintenance cycle
| Observation point | What to record | First checks when a result is abnormal |
|---|---|---|
| Maintenance cap or collection tray | Time drainage from suction start to the printer's specified residual-fluid condition. Observe whether air enters. | Cap seal, drain inlet position and valve state for the selected cleaning mode. |
| Waste ink container | Record the net mass added during one cleaning cycle. If acceptance is based on volume, measure the density of that waste mixture or collect and measure it directly at an approved point. | Flattened waste tubing, deposits in fittings, remaining container capacity and the model's venting or sealing requirements. |
| First pattern after returning to print | Run the model's nozzle-check procedure and compare patterns before cleaning, on the first print after recovery and once stable. | If waste volume meets the target but nozzles still drop out, distinguish cap maintenance issues from ink starvation at the inlet and faults in the nozzles themselves. |
After replacing the waste container, verify that the removable connection is fully engaged. Within the permitted maintenance program, test normal drainage, air entering toward the end and liquid arriving again on the next cycle. Record drain time and the first nozzle check separately so the cause of a failed cycle can be traced.
Selecting a waste pump for the medium at its inlet
If the tray supplies a continuous liquid stream, evaluate the DPL30-DB liquid diaphragm pump using the actual mixture of ink and approved cleaning fluid for material and installed-flow tests. If the cap sends alternating liquid slugs and air, evaluate the DPGL800-BS gas/liquid diaphragm pump. Its 6 L/min figure is an unloaded air-flow rating per pump head. Collect the waste from an actual maintenance cycle to establish liquid removal.[1][7]
Another design evacuates the air space of a purpose-built sealed waste bottle. The resulting vacuum draws waste into the bottle. Select the pump against the permissible vacuum of the bottle and head maintenance system, the effective gas volume and the time available to establish vacuum. Check lid sealing, full-bottle protection and safeguards against liquid entering the air line. Record time to vacuum and time to liquid arrival separately.[7]
To detect a break in the liquid column after changing a cleaning-fluid container, evaluate the ABD bubble detector on a suitable supply line. Test with the actual tube dimensions, material, fluid and bubble sizes of interest. Use the separate observations above to confirm cap sealing and waste arrival.[6]

DPL30-DB miniature liquid diaphragm pump
With continuous liquid in the tray, use the intended ink and cleaning-fluid mixture to measure the amount removed in one cycle and the residual volume in the tray.
View product details
ABD bubble detector
To determine when cleaning fluid returns after a container change, evaluate a sensor position on the feed line. Compare the actual liquid column with the detector signal to verify detection of interruptions.
View product details
Miniature liquid diaphragm pump selection
| Model | Free flow | Rated pressure | Candidate circuit duty |
|---|---|---|---|
| DPL30-DB | 300 mL/min | 100 kPa | Evaluate for lower-flow ink supply, return or small liquid-waste branches. |
The published specifications use purified water. Verify installed flow and wetted-material compatibility with the intended ink and cleaning fluid in the complete circuit. Free flow and rated pressure are separate specifications.
References
View references (7)
- [1]DPL30-DB product specifications
- [2]KNF guide to pumps for drop-on-demand inkjet supply, recirculation and maintenance
- [3]Mimaki maintenance instructions for the service station and waste ink path
- [4]Mimaki instructions for cleaning the cap and pump tubing
- [5]Mimaki UJF-3042/6042 MkII series operation manual, chapter 4: cleaning the nozzles and drain path
- [6]ABD bubble detector
- [7]DPGL800-BS gas/liquid diaphragm pump