Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Life science/Protein and antibody processing
< Back

Protein and antibody processing: buffer switching

Application guide

This guide covers buffer switching in protein and antibody processing: component roles, action sequence, operating conditions and restart requirements. Identify the architecture before comparing configurations.

Application guides

Protein and Antibody Handling Guide

Protein and antibody processing fluidics overview
Syringe pumps in protein and antibody processing
Sample transfer
Air-displacement pipetting pumps in protein and antibody processing
Diaphragm pumps in protein and antibody processing
Fluidic Valves for Protein and Antibody Handling
Buffer switching
Bubble and pressure detection in protein and antibody processing
Tubing and Fittings for Protein and Antibody Handling

ON THIS PAGE

Where buffer switching occurs in the instrumentProduct responsibilities in this operationOrganize the sequence by actual architectureDefine operating conditions for this taskCompare product configurations by the roles on this pageValidate operation results at the receiverLocate abnormalities and restore the next operationReferencesRelated guides

01Where buffer switching occurs in the instrument

Establish whether buffer switching occurs in preparation, loading or separation. Select the valve path for port pressures, media and shared-section volume, and validate composition and residue after displacement.

Estimate displacement from the shared volume, then use a measurable signal to confirm stability. A multiport valve selects sources; suitability for a separation branch also depends on the pressure it experiences.

02Product responsibilities in this operation

Valves control the current source or destination; the associated drive performs metering or transfer. Port connections, actual positioning and shared-segment renewal must match the operation.

For protein and antibody buffer switching, confirm all ports, valve states, pressures in each state, shared volume and exchange volume.

03Organize the sequence by actual architecture

  1. Locate buffer switching in the preparation, loading or pressurized separation branch first. Record media, pressures and target composition for each valve state separately.
  2. Select source-selection or high-pressure switching configurations suitable for that branch. Check port maps, interfaces and coordinated drives, and switch only in permitted states.
  3. Plan flushing from the shared volume, then use a method-appropriate signal to confirm arrival and stability of the new composition.
  4. Check residue, protein recovery and blanks after challenging switches. Evaluate low-pressure source selection and pressurized separation configurations separately.

04Define operating conditions for this task

Conditions, results and abnormality records for this operation
To defineDetails
Actual operating conditionsAll ports, valve states, pressures in each state, shared volume and flushing volume
Acceptance targetCheck unintended connections, leakage, backflow and post-switching residue in each state; measure flushing volume and arrival delay through the complete path
Fault localizationMisalignment, shared-segment residue or abnormal switching pressure may affect the next task

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
MRV3 multiport rotary valveMultiple-source selectionCompare 10-, 16- and 24-port options and port diagrams; verify high-pressure suitability separately
  • MRV3 multiport rotary valve

06Validate operation results at the receiver

Check unintended connections, leakage, backflow and post-switching residue in each state; measure flushing volume and arrival delay through the complete path.

Compare recovery and blanks before and after the complete path, and check the response after buffer switching.

07Locate abnormalities and restore the next operation

Misalignment, shared-segment residue or abnormal switching pressure may affect the next task.

Stop the pump, check port states and flush again after recovery.

A material name alone does not establish low adsorption. Confirm sample preparation, loading and pressurized separation branches separately.

References

View references (1)
  1. [1]FOREACH MRV3 multiport rotary valve: configurations and specifications

Related guides

  • Back to protein and antibody processing fluidics
  • Fluidic Valves for Protein and Antibody Handling

Related Products

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

Related Technical Articles

Rotary Valve Selection Guide: From Fluid Paths to System Validation

Map the connections required at each step before comparing specifications. Use the actual liquids, tubing and switching sequence to validate suitability for your instrument.

2026-09-30View Details

How Does a 6-Port HPLC Injection Valve Work? Load, Inject and Vent

Follow sample loading into an external loop and transfer to the column by the mobile phase, distinguishing the HP valve's main positions and vent path from the factors that determine injection volume.

2026-09-29View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss a protein and antibody fluidic configuration

Provide a fluid diagram, the actual liquids and pressures in each state. Compare 10-, 16- and 24-port configurations against the port map, and assess high-pressure suitability separately. Compare suitable configurations against the validation objectives described here.