Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Life science/Protein and antibody processing
< Back

Air-displacement pipetting pumps in protein and antibody processing

Application guide

Explore air-displacement pipetting-pump placement, coordination and configuration for tip-based protein sample preparation, with links to operating and validation tasks.

Application guides

Protein and Antibody Handling Guide

Protein and antibody processing fluidics overview
Syringe pumps in protein and antibody processing
Sample transfer
Air-displacement pipetting pumps in protein and antibody processing
Diaphragm pumps in protein and antibody processing
Fluidic Valves for Protein and Antibody Handling
Buffer switching
Bubble and pressure detection in protein and antibody processing
Tubing and Fittings for Protein and Antibody Handling

ON THIS PAGE

What do these products do in this instrument?Coordinate air-displacement drive with tips and motionDevelop pipetting sequences for actual liquids and receiving actionsTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageRelated operations and architecture comparisonsConfirm product roles in actual operationDoes completed pump movement confirm that the target well received the specified volume?ReferencesRelated guides

01What do these products do in this instrument?

Air-displacement pipetting pumps: tip-based protein sample preparation

Transfer samples, buffers or reaction formulations in disposable-tip workstations, using programs matched to the liquid and container. For low concentrations or volumes, check received volume, analyte recovery and blanks together.

SMTP serves disposable-tip air-displacement architectures, with the pump displacing an air column. Tip sealing, liquid type, immersion position and platform motion jointly determine received volume.

02Coordinate air-displacement drive with tips and motion

Air-displacement pipetting pumps move liquid in tips through air-column displacement. Sealing after pickup, tip specification, immersion and platform motion all contribute to aspiration and dispensing. Describe tip-based operations separately from fixed wetted tubing, identifying source well, receiving well and consumable state for each step.

03Develop pipetting sequences for actual liquids and receiving actions

Match aspiration speed, waits, air gaps and dispensing mode to the specific liquid and container. Low remaining volume, foam, droplets and post-tip-change state may affect reception. Schedule tip changes according to contamination-control requirements; when discarding liquid or recovering the protein-containing fraction, verify destination together with sample identity.

04Translate actual branch conditions into configuration requirements

Air-displacement pipetting-pump configuration for protein and antibody processing
ConditionTo confirm
Tips and sealingProvide tip specifications, pickup/ejection method and sealing checks after pickup.
Liquid and positionRecord liquid type, minimum remaining volume, immersion depth and receiving position.
Results by wellCheck received volume, empty wells or residual liquid, and tip-change and well records.
Operations supported in this instrument
OperationSpecific operating conditions
Sample transferActual sample volume, remaining source volume, probe-tip height, aspiration/dispensing speed and system liquid

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
SMTP air-displacement pipetting pumpAir displacement with disposable tipsValidate tip sealing, liquid type and motion together
  • SMTP air-displacement pipetting pump

06Related operations and architecture comparisons

Sample transfer

Pass protein samples through the actual tubing and vessels and compare with reference handling. Water calibration assesses volume; protein recovery assesses materials and workflow. Record them separately.

  • Sample transfer

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Sample transferMeasure delivered volume, protein recovery, aggregation or method response, and carryover between samples together.Material adsorption, aggregation, hanging droplets or residue can reduce recovery even when delivered volume meets requirements.

Compare recovery and blanks before and after the complete path, and check the response after buffer switching.

08Does completed pump movement confirm that the target well received the specified volume?

Also check tip sealing, air aspiration, well position and dispensing state, and measure actual reception. The drive-complete signal can assess the operation only together with these records.

A material name alone does not establish low adsorption. Confirm sample preparation, loading and pressurized separation branches separately.

References

View references (1)
  1. [1]FOREACH SMTP air-displacement pipetting pump: configurations and specifications

Related guides

  • Back to protein and antibody processing fluidics

Related Products

SMTP air-displacement pipetting pump; representative configuration. Select capacity, materials and interfaces for the application.

SMTP air-displacement pipetting pump

Related Technical Articles

What is a programmable automatic air-displacement pipetting pump?

A programmable automatic air-displacement pipetting pump is a liquid-handling component whose aspiration, dispense, speeds and sequence are set through control commands. This article focuses on air-displacement modules that use disposable tips in OEM instruments, with FOREACH SMTP2 as an example of operation, monitoring and selection limits.

2026-09-28View Details

What Is Pipetting? Manual and Automated Workflows Compared

Pipetting is the transfer of a specified volume of liquid from one location to another. Examples include moving 100 µL from a sample tube into a reaction vessel, or adding sample and diluent in a defined ratio.

2026-09-29View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss a protein and antibody fluidic configuration

Provide a fluid diagram, the actual liquids and pressures in each state. Tip sealing, liquid type and motion require joint validation. Compare suitable configurations against the validation objectives described here.

Contact an engineer