Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Analytical instruments/Analytical Sample Preparation
< Back

Analytical Sample Preparation: Disposable-Tip Transfer of Extracts and Target Phases

Application guide

Disposable-tip transfer of extracts and target phases is an analytical sample preparation task. This page explains component roles, operating sequence, actual operating conditions and restart requirements. Identify the architecture before comparing configurations.

Application guides

Analytical sample preparation application guide

Analytical sample preparation fluidics overview
Syringe pumps in analytical sample preparation
Automated dilution
Air-displacement pipetting pumps in analytical sample preparation
Tip-based transfer of extraction liquids and target phases
Multiport Rotary Valves for Analytical Sample Preparation
Tubing connections and protection in analytical sample preparation
Filtration

ON THIS PAGE

Where tip-based extract and target-phase transfer occurProduct responsibilities in this operationOrganize the sequence by actual architectureDefine operating conditions for this taskCompare product configurations by the roles on this pageValidate operation results at the receiverLocate abnormalities and restore the next operationReferencesRelated guides

01Where tip-based extract and target-phase transfer occur

Distinguish loading, washing, elution and phase transfer for the extraction method. Define phase state, pressure and product destinations, then evaluate target recovery, phase carryover and residue.

Loading, washing and elution send liquids to different destinations. Record phase carryover, product loss and vessel residue to assess aspiration position and switching timing.

02Product responsibilities in this operation

The air-displacement pump drives liquid inside the tip; the platform manages tips, wells and movement. Associate liquid destinations and consumable states with every operation.

For this analytical sample preparation task, confirm the retained phase or solid phase, waste and eluate destinations, aspiration height, permitted residual liquid and analyte.

03Organize the sequence by actual architecture

  1. For the specific extraction method, identify the phase containing the analyte, liquids to retain or discard, and receiving vessels. This page focuses on liquid transfers that tips can perform.
  2. Check tip compatibility with the actual solvent, sealing and container interfaces. Set aspiration height, speed and residual-liquid control to avoid mixing the target and unwanted phases.
  3. Transfer the appropriate liquid after method-specified separation or elution. Retain sample identity and destination records, and check phase carryover, vessel residue and consumables needing replacement.
  4. Assess the complete process using analyte recovery, phase carryover, blanks and residue. Operations requiring pressure through a fixed bed or another pressurized path need a suitable device configuration; air-displacement motion is not a direct substitute.

04Define operating conditions for this task

Conditions, results and abnormality records for this operation
To defineDetails
Actual operating conditionsPhase or solid phase to retain, waste and eluate destinations, aspiration height, allowable residue and analyte
Acceptance targetFor each loading, washing, elution or phase-transfer step, confirm the retained liquid and its destination. Measure analyte recovery, unwanted-phase carryover, vessel residue and blanks using the actual solvent and tip geometry.
Fault localizationAn incorrect aspiration interface, emulsion or retained droplet can transfer the wrong phase or lose product. Adsorption can reduce analyte recovery despite acceptable liquid volume.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
SMTP air-displacement pipetting pumpAir displacement with disposable tipsValidate tip sealing, liquid type and motion together
  • SMTP air-displacement pipetting pump

06Validate operation results at the receiver

For each loading, washing, elution or phase-transfer step, confirm the retained liquid and its destination. Measure analyte recovery, unwanted-phase carryover, vessel residue and blanks using the actual solvent and tip geometry.

Compare transfer at the intended phase interface and sample volume with the complete extraction result. A full receiving vessel does not establish that the correct phase or target fraction was recovered.

07Locate abnormalities and restore the next operation

An incorrect aspiration interface, emulsion or retained droplet can transfer the wrong phase or lose product. Adsorption can reduce analyte recovery despite acceptable liquid volume.

Preserve the identities of source, waste and product vessels and determine which phase was already transferred. Re-establish separation and replace affected consumables as permitted by the method before resuming; do not repeat a discard step on material of uncertain identity.

This task covers tip-based liquid transfers. Pressurized extraction through a fixed bed or other loaded path requires separately suitable equipment and method validation.

References

View references (1)
  1. [1]FOREACH SMTP air-displacement pipetting pump: configurations and specifications

Related guides

  • Return to the analytical sample preparation overview
  • Air-displacement pipetting pumps in analytical sample preparation

Related Products

SMTP air-displacement pipetting pump; representative configuration. Select capacity, materials and interfaces for the application.

SMTP air-displacement pipetting pump

Related Technical Articles

What is a programmable automatic air-displacement pipetting pump?

A programmable automatic air-displacement pipetting pump is a liquid-handling component whose aspiration, dispense, speeds and sequence are set through control commands. This article focuses on air-displacement modules that use disposable tips in OEM instruments, with FOREACH SMTP2 as an example of operation, monitoring and selection limits.

2026-09-28View Details

What Is Pipetting? Manual and Automated Workflows Compared

Pipetting is the transfer of a specified volume of liquid from one location to another. Examples include moving 100 µL from a sample tube into a reaction vessel, or adding sample and diluent in a defined ratio.

2026-09-29View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss fluidic configurations for analytical sample preparation

Provide a fluid diagram, the actual liquids and pressures in each state. Tip sealing, liquid type and motion require joint validation. Compare suitable configurations against the validation objectives described here.

Contact an engineer