Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Analytical instruments/Analytical Sample Preparation
< Back

Analytical Sample Preparation: Automated Dilution

Application guide

This guide covers automated dilution in analytical sample preparation: component roles, action sequence, operating conditions and restart requirements. Identify the architecture before comparing configurations.

Application guides

Analytical sample preparation application guide

Analytical sample preparation fluidics overview
Syringe pumps in analytical sample preparation
Automated dilution
Air-displacement pipetting pumps in analytical sample preparation
Tip-based transfer of extraction liquids and target phases
Multiport Rotary Valves for Analytical Sample Preparation
Tubing connections and protection in analytical sample preparation
Filtration

ON THIS PAGE

Where automated dilution fits in the instrumentProduct responsibilities in this operationOrganize the sequence by actual architectureDefine operating conditions for this taskCompare product configurations by the roles on this pageValidate operation results at the receiverLocate abnormalities and restore the next operationReferencesRelated guides

01Where automated dilution fits in the instrument

Determine ratios for samples, stock and diluent from actual delivered volumes. Shared-section residue, mixing and volume error jointly affect final concentration. Assess using blanks, ratio checks or spike recovery.

Sample and diluent errors, shared-section residue and mixing all affect final concentration. After assessing delivered volume, check the ratio, spiking result or method response.

02Product responsibilities in this operation

Syringe drive and valve positions jointly organize aspiration, holding and dispensing. Record working volume, remaining inventory and replenishment timing according to the sequence.

For analytical sample preparation, define actual sample, diluent or internal-standard volumes, concentrations at each stage, mixing and subsequent sampling conditions.

03Organize the sequence by actual architecture

  1. Identify the original sample, diluent and method-required additives. Record source identities, target ratios, preparation relationships between levels and final receiving location.
  2. In the syringe-driven fixed path, check each source and actual working volume separately, clear shared-section residue, then complete delivery from each path.
  3. Complete mixing for the actual container and method, then measure the received ratio and required concentration or response. Subsequent sampling must follow completed mixing.
  4. Assess the complete preparation using blanks, ratio checks or spike recovery, covering small doses, source switches and the first sample after maintenance. Investigate volume errors and analyte losses separately.

04Define operating conditions for this task

Conditions, results and abnormality records for this operation
To defineDetails
Actual operating conditionsActual volumes of original sample, diluent or internal standard; concentrations at each stage; mixing and resampling conditions
Acceptance targetMeasure each sample, stock, diluent or method-required additive at the receiving vessel. Verify the combined ratio and mixing before taking the next aliquot, including the smallest doses and source changes.
Fault localizationA missing addition, shared-path residue or incomplete mixing can change the prepared concentration. Later dilution levels can inherit that error even when their own commanded volumes are correct.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
HLD rotary-valve syringe pumpAspiration, holding and dispensing with a rotary valveCheck source/outlet valve positions, capacity budget and replenishment timing
HMD solenoid-valve syringe pumpMetered aspiration and dispensing with solenoid valvesCheck open/closed and power-off states, working volume and replenishment cycle
  • HLD rotary-valve syringe pump
  • HMD solenoid-valve syringe pump

06Validate operation results at the receiver

Measure each sample, stock, diluent or method-required additive at the receiving vessel. Verify the combined ratio and mixing before taking the next aliquot, including the smallest doses and source changes.

Check concentration or method response with the specified blanks, ratio checks or spike-recovery procedure. Investigate a correct volume with poor analyte recovery separately from a dosing error.

07Locate abnormalities and restore the next operation

A missing addition, shared-path residue or incomplete mixing can change the prepared concentration. Later dilution levels can inherit that error even when their own commanded volumes are correct.

Identify the affected preparation level and any aliquots already taken from it. Reconcile completed additions and mixing, restore the relevant source path, then remake or handle the affected preparation and downstream levels according to the method.

Accepted delivered volume is only part of dilution validation. The prepared composition, mixing and analyte recovery must meet the analytical method.

References

View references (2)
  1. [1]FOREACH HLD rotary-valve syringe pump: configurations and specifications
  2. [2]FOREACH HMD solenoid-valve syringe pump: configurations and specifications

Related guides

  • Return to the analytical sample preparation overview
  • Syringe pumps in analytical sample preparation

Related Products

HLD rotary-valve syringe pump; representative configuration. Select capacity, materials and interfaces for the application.

HLD rotary-valve syringe pump

HMD solenoid-valve syringe pump; representative configuration. Select capacity, materials and interfaces for the application.

HMD solenoid-valve syringe pump

Related Technical Articles

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

What Is Pipetting? Manual and Automated Workflows Compared

Pipetting is the transfer of a specified volume of liquid from one location to another. Examples include moving 100 µL from a sample tube into a reaction vessel, or adding sample and diluent in a defined ratio.

2026-09-29View Details

Discuss fluidic configurations for analytical sample preparation

Provide a fluid-path diagram, actual liquids and pressures in every state. Specify source and outlet valve positions, capacity budgets and refill timing, including open, closed and power-off states, working volumes and replenishment cycles. Compare configurations against the validation objectives in this guide.