Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Analytical instruments/Analytical Sample Preparation
< Back

Analytical Sample Preparation: Selecting for Dilution Ratio, Extraction Recovery and Blanks

Application guide

Analytical preparation aims to produce a sample that meets method requirements. Dilution, extraction and filtration have distinct material balances and sources of loss. Assess pump and valve protection separately from analytical recovery. Identify the phase or liquid fraction carrying the analyte before defining aspiration, dispensing and switching.

Application guides

Analytical sample preparation application guide

Analytical sample preparation fluidics overview
Syringe pumps in analytical sample preparation
Automated dilution
Air-displacement pipetting pumps in analytical sample preparation
Tip-based transfer of extraction liquids and target phases
Multiport Rotary Valves for Analytical Sample Preparation
Tubing connections and protection in analytical sample preparation
Filtration

ON THIS PAGE

Locate the task in the fluid path firstCommon product roles and application guidesOperating requirements differ by stepAutomated dilution: establish ratios from actual deliveryExtraction and phase transfer: establish which phase contains the productFiltration: define its role in the method firstExplore configurations through product application guidesValidate the complete cycle through application resultsCommon selection and recovery questionsReferencesRelated guides

01Locate the task in the fluid path first

Original sample→Method-specified pretreatment→Target retention or transfer→Analytical sample collection→Blank and recovery validation
Illustrative task sequence. Confirm sampling, washing, waste and monitoring branches separately against the instrument drawings.

Arrows indicate task relationships, not that every component is connected in series in one tube. Check valve positions, pump wetted boundaries and operating states for each branch.

Use receiving ratio, target recovery and blanks as selection criteria, rather than unobstructed flow alone. Phase state, viscosity, materials and pressure all affect candidates. Check the first sample after maintenance as well.

02Common product roles and application guides

Explore product applications by their role in the instrument
Product categoryRole in this instrument
Syringe pumpDilution and volumetric transfer
Air-displacement pipetting pumpTip-based transfer and sample preparation
Multiport rotary valveRouting samples, solvents and recovered products
Tubing connections and protectionMethod-specified sample treatment or protection; complete transfer paths that retain the target
  • Syringe pumps in analytical sample preparation
  • Air-displacement pipetting pumps in analytical sample preparation
  • Multiport Rotary Valves for Analytical Sample Preparation
  • Tubing connections and protection in analytical sample preparation

03Operating requirements differ by step

Define fluid-path responsibilities before examining individual operations
StageTask categoryOperating conditions to define
Automated dilution: establish ratios from actual deliveryProportion-based preparationActual volumes of original sample, diluent or internal standard; concentrations at each stage; mixing and resampling conditions
Extraction and phase transfer: establish which phase contains the productSeparation and product recoveryPhase or solid phase to retain, waste and eluate destinations, aspiration height, allowable residue and analyte
Filtration: define its role in the method firstProtection and method conditionsTarget components, pore size/material, filtration area, pressure drop, check-valve cracking pressure and leakage

04Automated dilution: establish ratios from actual delivery

Sample and diluent errors, shared-section residue and mixing all affect final concentration. After assessing delivered volume, check the ratio, spiking result or method response.

  • Automated dilution

05Extraction and phase transfer: establish which phase contains the product

Loading, washing and elution send liquids to different destinations. Record phase carryover, product loss and vessel residue to assess aspiration position and switching timing.

  • Tip-based transfer of extraction liquids and target phases

06Filtration: define its role in the method first

Sample-processing filters and pump/valve protection filters may require different locations. Identify the analyte before choosing pore size and material. Measure blanks, recovery and the first sample after replacement.

  • Filtration

07Explore configurations through product application guides

  • Syringe pumps in analytical sample preparation
  • Air-displacement pipetting pumps in analytical sample preparation
  • Multiport Rotary Valves for Analytical Sample Preparation
  • Tubing connections and protection in analytical sample preparation

08Validate the complete cycle through application results

Evaluate ratio, mixing, blanks and target recovery at the receiving position.

Plan operating-point validation and fault investigation for each step
Step to validateMeasurements or observationsPriority troubleshooting checks
Automated dilution: establish ratios from actual deliveryMeasure each branch's delivery, received ratio and mixing uniformity separately, then check assay responseSmall-volume errors, shared residual liquid or inadequate mixing may alter the actual ratio
Extraction and phase transfer: establish which phase contains the productMeasure target recovery, phase carryover, blanks and residueIncorrect aspiration position, phase carryover or surface adsorption may cause product loss.
Filtration: define its role in the method firstEvaluate targets before and after filtration, blanks, recovery or method-specified metrics. Check increasing pressure drop, backflow protection and recovery after replacement.Clogging, adsorption, leaks or excessive cracking pressure can alter delivery or method results

Filtration and extraction can change sample composition. Mechanical protection does not replace method-recovery validation.

09Common selection and recovery questions

Should the pump be recalibrated immediately when diluted concentration is wrong?

Check sample and diluent delivery separately, then shared-section residue, mixing and resampling. Establish whether the issue concerns volume, composition or the method before making adjustments.

What determines aspiration height during extraction?

Identify the analyte-containing phase and retained or discarded destinations. Set actions using the interface, vessel geometry and residual liquid, then assess recovery and phase carryover.

References

View references (3)
  1. [1]FOREACH syringe pumps: configurations and specifications
  2. [2]FOREACH SMTP air-displacement pipetting pumps: configurations and specifications
  3. [3]FOREACH Filters: Configurations and Specifications

Related guides

  • Tip-based preparation and recovery
  • Syringe Pump Dilution and Preparation

Related Products

HLD rotary-valve syringe pump; representative configuration. Select capacity, materials and interfaces for the application.

HLD rotary-valve syringe pump

SMTP air-displacement pipetting pump; representative configuration. Select capacity, materials and interfaces for the application.

SMTP air-displacement pipetting pump

PE-Series Filters; representative configuration. Select capacity, materials and interfaces for the application.

PE-Series Filters

Related Technical Articles

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

What is a programmable automatic air-displacement pipetting pump?

A programmable automatic air-displacement pipetting pump is a liquid-handling component whose aspiration, dispense, speeds and sequence are set through control commands. This article focuses on air-displacement modules that use disposable tips in OEM instruments, with FOREACH SMTP2 as an example of operation, monitoring and selection limits.

2026-09-28View Details

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Discuss your analytical sample preparation fluidics

Provide a fluid diagram, the actual liquids and pressures in each state. Specify ratios, phases and materials, liquid types and product recovery, and adsorption, volume and resistance. Compare suitable configurations against the validation objectives described here.

Contact an engineer