Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Environmental monitoring/Environmental sample preparation
< Back

Environmental Sample Preparation: Filtration

Application guide

This guide covers filtration in environmental sample preparation: component roles, action sequence, operating conditions and restart requirements. Identify the architecture before comparing configurations.

Application guides

Environmental sample preparation application guide

Environmental sample preparation fluidics overview
Syringe Pumps for Environmental Sample Preparation
Dilution
Air-displacement pipetting pumps in environmental sample preparation
Tip-based environmental sample aliquoting and transfer
Multiport Rotary Valves for Environmental Sample Preparation
Tubing connections and protection in environmental sample preparation
FiltrationWaste and washing

ON THIS PAGE

Where filtration occurs in the instrumentProduct responsibilities in this operationOrganize the sequence by actual architectureDefine operating conditions for this taskCompare product configurations by the roles on this pageValidate operation results at the receiverLocate abnormalities and restore the next operationReferencesRelated guides

01Where filtration occurs in the instrument

Choose pore size, material and whether to filter from the analytical target. Record composition before and after filtration, adsorption, pressure drop and replacement effects. Mechanical blockage protection does not automatically improve sample quality.

Pore size, medium and position depend on the method. Check targets, adsorption and pressure drop before and after filtration, and the first sample after replacement.

02Product responsibilities in this operation

Tubing, fittings and the protection components described here form the actual path. Validate materials, passage dimensions, connection volume and maintenance state with this operation.

For environmental sample preparation, define the target fraction, filter material and pore size, filtration location, added volume, actual pressure drop and permitted maintenance. Establish whether particles must be retained for the method.

03Organize the sequence by actual architecture

  1. Confirm the analytical target and whether filtration is permitted, then define treatment location, medium and conditions according to the method.
  2. Record samples before and after filtration. Check target retention, adsorption, actual throughput and changes in pressure drop.
  3. After filter replacement or cleaning, check blanks and the first sample, then pass treatment conditions and sample identity to the analytical step.

04Define operating conditions for this task

Conditions, results and abnormality records for this operation
To defineDetails
Actual operating conditionsThe method-defined analyte fraction, whether particles must be retained in the sample, filter material and pore size, filter location, added volume, pressure drop and replacement conditions
Acceptance targetConfirm that filtration preserves the fraction required by the method. Compare blanks and analyte recovery, check flow and pressure drop as solids accumulate, and verify the first sample after filter replacement.
Fault localizationAn unsuitable filter can remove the fraction being measured; adsorption, clogging or leakage can change composition and sample arrival. Verify the filter, seals, sample refresh and method response before accepting the next result.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
PE-Series FiltersParticle retention permitted by the methodCards show representative configurations. Select actual pore size and filter material for the target, pressure drop and recovery requirements.
Tubing materials and dimensionsConnection paths and shared volumeBore, length, load and actual formulation jointly determine materials and dimensions
Rigid-tubing fittingsTube-end positioning and sealed connectionsCheck tube outer diameter, threads, seal structure and port-bottom geometry
  • PE-Series Filters
  • Tubing materials and dimensions
  • Rigid-tubing fittings

06Validate operation results at the receiver

Confirm that filtration preserves the fraction required by the method. Compare blanks and analyte recovery, check flow and pressure drop as solids accumulate, and verify the first sample after filter replacement.

Evaluate blanks, recovery, aliquot representativeness and restart according to the method.

07Locate abnormalities and restore the next operation

An unsuitable filter can remove the fraction being measured; adsorption, clogging or leakage can change composition and sample arrival. Verify the filter, seals, sample refresh and method response before accepting the next result.

Confirm the filtration path and sealing, then recheck actual flow, sample renewal and method results before resuming.

Filter selection and pressure-drop checks must be evaluated alongside field preservation, particle distribution and possible loss of the analyte fraction required by the method.

References

View references (3)
  1. [1]FOREACH PE series filters: configurations and specifications
  2. [2]FOREACH tubing materials and dimensions: configurations and specifications
  3. [3]FOREACH rigid-tubing fittings: configurations and specifications

Related guides

  • Return to the environmental sample preparation overview
  • Tubing connections and protection in environmental sample preparation
  • Waste and washing

Related Products

PE-Series Filters; representative configuration. Select capacity, materials and interfaces for the application.

PE-Series Filters

Tubing materials and dimensions; representative configuration. Select capacity, materials and interfaces for the application.

Tubing materials and dimensions

Rigid-tubing fittings; representative configuration. Select capacity, materials and interfaces for the application.

Rigid-tubing fittings

Related Technical Articles

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Why Does Actual Flow Change So Much When the Tubing Size Changes on the Same Miniature Diaphragm Pump?

Even when the pump is unchanged, installed flow can change because of tubing inner diameter, length, bends, and the minimum bore of fittings. When flow falls after a tubing change, the effective response is neither to blame the pump first nor to enlarge every tube indiscriminately. Measure inlet pressure, outlet pressure, and accumulated flow together to determine where the added restriction actually occurs.

2026-08-24View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss an environmental sample preparation configuration

Provide a fluidic diagram, actual liquids and pressures in each operating state. Cards show representative configurations; choose actual pore size and filter material for the analyte, pressure drop and recovery. Select tubing material and dimensions using bore, length, load and formulation. Check OD, threads, sealing structure and port-bottom geometry. Compare configurations against this guide's validation objectives.

Contact an engineer