Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Environmental monitoring/Online Water-Quality Sampling
< Back

Online water sampling: protective filtration

Application guide

This guide covers protective filtration in online water sampling: component roles, action sequence, operating conditions and restart requirements. Identify the architecture before comparing configurations.

Application guides

Online water sampling application guide

Fluidic Overview for Online Water-Quality Sampling
Diaphragm pumps in online water sampling
Field sampling and transferField reagent supply and recovery after bottle changesCleaning and waste removal
Multiport rotary valves in online water sampling
Operating-state switching
Bubble and pressure sensing in online water sampling
Connections and protection in online water sampling
Protective filtration

ON THIS PAGE

Where protective filtration occurs in the instrumentProduct responsibilities in this operationOrganize the sequence by actual architectureDefine operating conditions for this taskCompare product configurations by the roles on this pageValidate operation results at the receiverLocate abnormalities and restore the next operationReferencesRelated guides

01Where protective filtration occurs in the instrument

Filtration must first meet measured-component and method requirements, then provide pump/valve protection. Record increasing pressure drop, consumable replacement and sample changes. A filtered sample must not be assumed to represent all raw-water components.

Choose protection locations according to the method and record filter pressure drop and sample differences before and after maintenance. Filtered water must not automatically be treated as representative of total constituents in the original water.

02Product responsibilities in this operation

Tubing, fittings and the protection components described here form the actual path. Validate materials, passage dimensions, connection volume and maintenance state with this operation.

For online water-sampling protection, confirm analytical target, filter material and pore size, location, added volume, actual pressure drop and permitted maintenance.

03Organize the sequence by actual architecture

  1. Determine whether filtration is permitted by the monitoring method and target fraction. Define the protection location and particles or dissolved constituents that must be retained.
  2. Confirm filter material and conditions using the actual water sample. Record initial flow, pressure drop and analytes before and after filtration, assessing protection and sample changes separately.
  3. During operation and after replacement, check clogging trends, blanks and sample renewal. Confirm the first measurement according to the method. Filtered water does not automatically represent total constituents in the original water.

04Define operating conditions for this task

Conditions, results and abnormality records for this operation
To defineDetails
Actual operating conditionsAnalytical target, filter material/pore size, filtration location, added volume, actual pressure drop and permitted maintenance
Acceptance targetCompare analytes, recovery and blanks before and after filtration. Check pressure drop and actual flow after loading accumulates, and the first sample after replacement.
Fault localizationBlockage, adsorption, leakage or added filter-assembly volume can change the sample and its arrival time.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
PE-Series FiltersParticle retention permitted by the methodCards show representative configurations. Select actual pore size and filter material for the target, pressure drop and recovery requirements.
Tubing materials and dimensionsConnection paths and shared volumeBore, length, load and actual formulation jointly determine materials and dimensions
Rigid-tubing fittingsTube-end positioning and sealed connectionsCheck tube outer diameter, threads, seal structure and port-bottom geometry
  • PE-Series Filters
  • Tubing materials and dimensions
  • Rigid-tubing fittings

06Validate operation results at the receiver

Compare analytes, recovery and blanks before and after filtration. Check pressure drop and actual flow after loading accumulates, and the first sample after replacement.

Compare field and received samples for representativeness. Measure actual refresh and recovery after maintenance.

07Locate abnormalities and restore the next operation

Clogging, adsorption, leakage or added filter-assembly volume can change the sample and arrival time.

Confirm the filtration path and sealing, then recheck actual flow, sample renewal and method results before resuming.

Nominal volume divided by flow estimates transport time; it does not establish complete sample renewal or representativeness.

References

View references (3)
  1. [1]FOREACH PE series filters: configurations and specifications
  2. [2]FOREACH tubing materials and dimensions: configurations and specifications
  3. [3]FOREACH rigid-tubing fittings: configurations and specifications

Related guides

  • Return to the online water-quality sampling overview
  • Connections and protection in online water sampling

Related Products

PE-Series Filters; representative configuration. Select capacity, materials and interfaces for the application.

PE-Series Filters

Tubing materials and dimensions; representative configuration. Select capacity, materials and interfaces for the application.

Tubing materials and dimensions

Rigid-tubing fittings; representative configuration. Select capacity, materials and interfaces for the application.

Rigid-tubing fittings

Related Technical Articles

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Why Does Actual Flow Change So Much When the Tubing Size Changes on the Same Miniature Diaphragm Pump?

Even when the pump is unchanged, installed flow can change because of tubing inner diameter, length, bends, and the minimum bore of fittings. When flow falls after a tubing change, the effective response is neither to blame the pump first nor to enlarge every tube indiscriminately. Measure inlet pressure, outlet pressure, and accumulated flow together to determine where the added restriction actually occurs.

2026-08-24View Details

Selecting a Self-Priming Miniature Liquid Diaphragm Pump: Lift, Priming Time and Dry or Wet Starts

Select a self-priming miniature liquid diaphragm pump by checking suction lift, time to first liquid, dry and wet starting conditions, and stable delivery. Use DPL30, DPL60 and DPL30H specifications to define an instrument-level test.

2026-09-07View Details

Discuss fluidic configurations for online water monitoring

Provide a fluidic diagram, actual liquids and pressures in each operating state. Cards show representative configurations; choose actual pore size and filter material for the analyte, pressure drop and recovery. Select tubing material and dimensions using bore, length, load and formulation. Check OD, threads, sealing structure and port-bottom geometry. Compare configurations against this guide's validation objectives.

Contact an engineer