Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Synthetic biology/Bioprocess Integration
< Back

Tubing and fittings in bioprocess integration

Application guide

This page explains tubing and fitting locations, coordination and configuration requirements for prolonged liquid contact and sealed module connections in bioprocess integration, with links to relevant operating and validation tasks.

Application guides

Bioprocess Integration Guide

Bioprocess integration fluidics overview
Syringe pumps in bioprocess integration
Valveless Metering Pumps for Bioprocess Integration
Diaphragm pumps in bioprocess integration
Fluidic valves in bioprocess integration
Paths and interlocks
Bubble and Pressure Monitoring for Bioprocess Integration
Tubing and fittings in bioprocess integration

ON THIS PAGE

What do these products do in this instrument?Design tubing and fittings as a complete wetted pathCalculate connection volume and post-maintenance recoveryTranslate actual branch conditions into configuration requirementsModule connectionsCompare product configurations by the roles on this pageConfirm product roles in actual operationDoes a fitting that tightens prove the tubing assembly is suitable?ReferencesRelated guides

01What do these products do in this instrument?

Tubing and Fittings: Long-Term Wetted Paths and Sealed Module Connections

Connect culture vessels, feed, sampling and waste modules. Confirm materials and seals for temperature, run duration and maintenance procedures. After disassembly, recheck contamination boundaries and actual routing before resuming automatic operation.

Tubing and fittings together form sealed connections and the actual transfer path. Check formulation, inner/outer diameters, length, tube-end positioning and port geometry, including added volume in residue and arrival delay.

02Design tubing and fittings as a complete wetted path

Tubing, fittings and ports jointly determine sealing, transfer volume and medium-contact coverage. Materials and dimensions must suit formulation, operating conditions and installation. Include tubing length and interface volume in priming, shared residue and arrival delay. After connection changes, recheck delivery and cleaning through the actual path.

03Calculate connection volume and post-maintenance recovery

Shared volume affects liquid arrival and flushing; interface gaps may retain the previous composition. Record length, actual bore and tube insertion position. After disassembly, reprime and check seals, then compare first-cycle delivery, blanks or recovered product to confirm path recovery.

04Translate actual branch conditions into configuration requirements

Tubing and Fitting Configuration for Bioprocess Integration
ConditionTo confirm
Materials and assemblyProvide formulation, tubing inner/outer diameters, length, fitting structure and port fit.
Volume and loadCalculate shared and replacement-component added volumes; measure actual flow and response.
Maintenance recoveryRecord disassembly locations and added volume; recheck priming, sealing and first-cycle received results.
Operations supported in this instrument
OperationSpecific operating conditions
Module connectionsTubing ID/OD, length, interface geometry, pressure, materials and maintenance method

05Module connections

Confirm wetted materials, seals and replacement methods between culture vessels, reagents, waste and sensors. Validate connections for cleaning or sterilization and extended temperature exposure. Recheck contamination boundaries after maintenance.

Evaluate materials, seals and connection methods against temperature and cleaning or sterilization procedures. Recheck contamination boundaries after maintenance before releasing automatic operation.

Check leaks, tube disconnection and material changes at actual pressure and temperature; evaluate residue, recovery and the first post-maintenance cycle through the complete path

Misconnections, gaps, tube deformation or leaks may alter volume and pressure. Isolate the affected segment and reconfirm assembly; matching threads do not establish interchangeability.

06Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
Tubing materials and dimensionsConnection paths and shared volumeBore, length, load and actual formulation jointly determine materials and dimensions
Rigid-tubing fittingsTube-end positioning and sealed connectionsCheck tube outer diameter, threads, seal structure and port-bottom geometry
  • Tubing materials and dimensions
  • Rigid-tubing fittings

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Module connectionsCheck leaks, tube disconnection and material changes at actual pressure and temperature; evaluate residue, recovery and the first post-maintenance cycle through the complete pathMisconnections, gaps, tube deformation or leaks may alter volume and pressure

Include extended operation, power loss, depleted feed, blockage and post-maintenance restart. Check cumulative delivery and contamination boundaries.

08Does a fitting that tightens prove the tubing assembly is suitable?

Also confirm port geometry, tube-end positioning and seal fit. Check leakage, hold-up and performance after repeated maintenance under actual conditions; thread engagement alone is insufficient.

Evaluate fluidic feedback and biological process results separately. A component combination alone does not establish sterility or continuous-culture capability.

References

View references (2)
  1. [1]FOREACH tubing materials and dimensions: configurations and specifications
  2. [2]FOREACH rigid-tubing fittings: configurations and specifications

Related guides

  • Return to the bioprocess integration overview

Related Products

Tubing materials and dimensions; representative configuration. Select capacity, materials and interfaces for the application.

Tubing materials and dimensions

Rigid-tubing fittings; representative configuration. Select capacity, materials and interfaces for the application.

Rigid-tubing fittings

Related Technical Articles

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Why Does Actual Flow Change So Much When the Tubing Size Changes on the Same Miniature Diaphragm Pump?

Even when the pump is unchanged, installed flow can change because of tubing inner diameter, length, bends, and the minimum bore of fittings. When flow falls after a tubing change, the effective response is neither to blame the pump first nor to enlarge every tube indiscriminately. Measure inlet pressure, outlet pressure, and accumulated flow together to determine where the added restriction actually occurs.

2026-08-24View Details

Valveless Metering Pump Selection Guide: FOREACH Models and Applications

To select a valveless metering pump, first define the volume per dose and the time available for dispensing. Then check displacement per revolution, drive speed, wetted materials, backpressure and connections, and verify delivery in the actual fluid path. Neither flow rate alone nor the label ‘metering pump’ is enough to select a model.

2026-09-16View Details

Discuss fluidic configurations for bioprocess integration

Provide a fluid diagram, the actual liquids and pressures in each state. Bore size, length, load and actual formulation jointly determine material and dimensional choices. Check tubing OD, threads, sealing structure and port-bottom geometry. Compare suitable configurations against the validation objectives described here.

Contact an engineer