Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Synthetic biology/Bioprocess Integration
< Back

Fluidic valves in bioprocess integration

Application guide

This page explains fluidic valve positions, supporting components and configuration requirements for routing process tasks, tubing-path shutoff and module maintenance, with links to operating and validation tasks.

Application guides

Bioprocess Integration Guide

Bioprocess integration fluidics overview
Syringe pumps in bioprocess integration
Valveless Metering Pumps for Bioprocess Integration
Diaphragm pumps in bioprocess integration
Fluidic valves in bioprocess integration
Paths and interlocks
Bubble and Pressure Monitoring for Bioprocess Integration
Tubing and fittings in bioprocess integration

ON THIS PAGE

What do these products do in this instrument?Define connections using the instrument's port-state diagramInclude renewal of shared segments after switching in the sequenceTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageExplore specific operating and validation tasksConfirm product roles in actual operationDo more valve ports mean more channels can supply liquid simultaneously?ReferencesRelated guides

01What do these products do in this instrument?

Multiport rotary valves: connecting multiple process tasks

Route feeding, sampling and maintenance in source-selection configurations, coordinated with interlocks and culture-vessel identity. Define operating and fault states, checking unintended connections and closed-state isolation.

MRV3 selects sources or destinations and requires a port-state diagram and shared-volume budget. Port count indicates routing options; confirm pressure in each state and independent simultaneous supply requirements separately.

Pinch-valve arrangements: flexible-path isolation and module maintenance

Open or close branches at the actual tubing-control locations, coordinated with module replacement and process restart. Confirm tubing, fittings, closure sealing and cleaning or sterilization steps together.

Discuss tubing pinch-off for the specific project. Tubing and fittings define the liquid-contact path. Validate tubing material, wall thickness, pinch seal and replacement procedure together, and assess cleaning or sterilization across the complete path.

02Define connections using the instrument's port-state diagram

This page covers multiport rotary valves and tubing pinch-off solutions. Identify every port, current source, receiving destination and branch requiring isolation. Check connectivity during aspiration, delivery, washing, maintenance and power loss. Valve selection actions must correspond to permitted drive conditions.

03Include renewal of shared segments after switching in the sequence

After source switching, shared tubing may retain the previous composition. Record volume and arrival delay from the new source to the receiver, and measure residue and recovery for the actual worst-case switching combination. Confirm port positioning and arrival of new liquid separately.

04Translate actual branch conditions into configuration requirements

Fluidic-valve configuration requirements for bioprocess integration
ConditionTo confirm
Connections and pressureProvide port diagrams and pressure conditions for all operating, cleaning and shutdown states.
Shared volumeIdentify residue locations after source changes, flushing volumes and discharge destinations.
Control and isolationCheck valve-position feedback, pump actions, shutoff leakage and permitted power-off states.
Operations supported in this instrument
OperationSpecific operating conditions
Paths and interlocksTask state, sample or vessel identity, concurrent resources, interlocks and restart

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
MRV3 multiport rotary valveMultiple-source selectionCompare 10-, 16- and 24-port options and port diagrams; verify high-pressure suitability separately
  • MRV3 multiport rotary valve

06Explore specific operating and validation tasks

Paths and interlocks

Concurrent tasks must prevent wash liquid, waste or other formulations entering culture paths. Include fault states and maintenance bypasses on the same drawings.

  • Paths and interlocks

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Paths and interlocksTest concurrent operation, limiting states and complete fault recovery; verify that identities, cumulative quantities and records match actual actionsResource conflicts, communication loss or mismatched identities can cause delivery to the wrong destination or repeated dosing.

Include extended operation, power loss, depleted feed, blockage and post-maintenance restart. Check cumulative delivery and contamination boundaries.

08Do more valve ports mean more channels can supply liquid simultaneously?

Check port connection structure and drive configuration. The number of selectable sources, independent paths and simultaneous-operation capability are different conditions, determined by actual connections in each state.

Evaluate fluidic feedback and biological process results separately. A component combination alone does not establish sterility or continuous-culture capability.

References

View references (1)
  1. [1]FOREACH MRV3 multiport rotary valve: configurations and specifications

Related guides

  • Return to the bioprocess integration overview
  • Paths and interlocks

Related Products

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

Related Technical Articles

Rotary Valve Selection Guide: From Fluid Paths to System Validation

Map the connections required at each step before comparing specifications. Use the actual liquids, tubing and switching sequence to validate suitability for your instrument.

2026-09-30View Details

How Does a 6-Port HPLC Injection Valve Work? Load, Inject and Vent

Follow sample loading into an external loop and transfer to the column by the mobile phase, distinguishing the HP valve's main positions and vent path from the factors that determine injection volume.

2026-09-29View Details

Valveless Metering Pump Selection Guide: FOREACH Models and Applications

To select a valveless metering pump, first define the volume per dose and the time available for dispensing. Then check displacement per revolution, drive speed, wetted materials, backpressure and connections, and verify delivery in the actual fluid path. Neither flow rate alone nor the label ‘metering pump’ is enough to select a model.

2026-09-16View Details

Discuss fluidic configurations for bioprocess integration

Provide a fluid diagram, the actual liquids and pressures in each state. Compare 10-, 16- and 24-port configurations against the port map, and assess high-pressure suitability separately. Compare suitable configurations against the validation objectives described here.