Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Synthetic biology/Continuous feeding
< Back

Fluidic valves in continuous feeding

Application guide

Explore fluidic-valve placement, coordination and configuration for formulation and replenishment-source selection, flexible-branch isolation and maintenance in continuous feeding, with links to operating and validation tasks.

Application guides

Continuous feeding application guide

Continuous feeding fluidics overview
Syringe pumps in continuous feeding
Valveless Metering Pumps for Continuous Feeding
Supply mode
Fluidic valves in continuous feeding
Medium switching
Bubble and pressure sensing in continuous feeding
Fluidic Connections and Protection for Continuous Feeding
Flow-path protection

ON THIS PAGE

What do these products do in this instrument?Define connections using the instrument's port-state diagramInclude renewal of shared segments after switching in the sequenceTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageExplore specific operating and validation tasksConfirm product roles in actual operationDo more valve ports mean more channels can supply liquid simultaneously?ReferencesRelated guides

01What do these products do in this instrument?

Multiport Rotary Valves: Formulation and Refill-Source Selection

In selector-valve configurations, connect the current medium or maintenance path with priming and feed control. Specify destinations for old formulation and wash liquid, then verify arrival of the new composition at the culture vessel.

MRV3 selects sources or destinations and requires a port-state diagram and shared-volume budget. Port count indicates routing options; confirm pressure in each state and independent simultaneous supply requirements separately.

Tubing pinch-off solutions: flexible-branch isolation and maintenance

Control flow in tubing-pinch feed paths, coordinated with bottle changes, maintenance and restart. Confirm sealing, tubing condition and complete cleaning or sterilization procedures for the actual system.

Discuss tubing pinch-off for the specific project. Tubing and fittings define the liquid-contact path. Validate tubing material, wall thickness, pinch seal and replacement procedure together, and assess cleaning or sterilization across the complete path.

02Define connections using the instrument's port-state diagram

This page covers multiport rotary valves and tubing pinch-off solutions. Identify every port, current source, receiving destination and branch requiring isolation. Check connectivity during aspiration, delivery, washing, maintenance and power loss. Valve selection actions must correspond to permitted drive conditions.

03Include renewal of shared segments after switching in the sequence

After source switching, shared tubing may retain the previous composition. Record volume and arrival delay from the new source to the receiver, and measure residue and recovery for the actual worst-case switching combination. Confirm port positioning and arrival of new liquid separately.

04Translate actual branch conditions into configuration requirements

Fluidic Valve Configuration for Continuous Feeding
ConditionTo confirm
Connections and pressureProvide port diagrams and pressure conditions for all operating, cleaning and shutdown states.
Shared volumeIdentify residue locations after source changes, flushing volumes and discharge destinations.
Control and isolationCheck valve-position feedback, pump actions, shutoff leakage and permitted power-off states.
Operations supported in this instrument
OperationSpecific operating conditions
Medium switchingAll ports, valve states, pressures in each state, shared volume and flushing volume

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
MRV3 multiport rotary valveMultiple-source selectionCompare 10-, 16- and 24-port options and port diagrams; verify high-pressure suitability separately
  • MRV3 multiport rotary valve

06Explore specific operating and validation tasks

Medium switching

Bottle changes, priming and switching are different events. Calculate shared volume, then verify arrival time and initial composition to prevent cleaning residue entering the culture.

  • Medium switching

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Medium switchingCheck unintended connections, leakage, backflow and post-switching residue in each state; measure flushing volume and arrival delay through the complete pathMisalignment, shared-segment residue or abnormal switching pressure may affect the next task

Record output across the run, replenishment interruptions, first flow after bottle changes and reactor volume balance.

08Do more valve ports mean more channels can supply liquid simultaneously?

Check port connection structure and drive configuration. The number of selectable sources, independent paths and simultaneous-operation capability are different conditions, determined by actual connections in each state.

Refilling or resetting a single syringe can interrupt supply. Continuous-operation capability and aseptic isolation both require system validation.

References

View references (1)
  1. [1]FOREACH MRV3 multiport rotary valve: configurations and specifications

Related guides

  • Back to the continuous feeding fluidics overview
  • Medium switching

Related Products

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

Related Technical Articles

Rotary Valve Selection Guide: From Fluid Paths to System Validation

Map the connections required at each step before comparing specifications. Use the actual liquids, tubing and switching sequence to validate suitability for your instrument.

2026-09-30View Details

How Does a 6-Port HPLC Injection Valve Work? Load, Inject and Vent

Follow sample loading into an external loop and transfer to the column by the mobile phase, distinguishing the HP valve's main positions and vent path from the factors that determine injection volume.

2026-09-29View Details

Valveless Metering Pump Selection Guide: FOREACH Models and Applications

To select a valveless metering pump, first define the volume per dose and the time available for dispensing. Then check displacement per revolution, drive speed, wetted materials, backpressure and connections, and verify delivery in the actual fluid path. Neither flow rate alone nor the label ‘metering pump’ is enough to select a model.

2026-09-16View Details

Discuss fluidic configurations for continuous feeding

Provide a fluid diagram, the actual liquids and pressures in each state. Compare 10-, 16- and 24-port configurations against the port map, and assess high-pressure suitability separately. Compare suitable configurations against the validation objectives described here.

Contact an engineer