Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Synthetic biology/Continuous feeding
< Back

Bubble and pressure sensing in continuous feeding

Application guide

This page explains bubble and pressure monitoring positions, supporting components and configuration requirements for recording feed-anomaly time windows, with links to operating and validation tasks.

Application guides

Continuous feeding application guide

Continuous feeding fluidics overview
Syringe pumps in continuous feeding
Valveless Metering Pumps for Continuous Feeding
Supply mode
Fluidic valves in continuous feeding
Medium switching
Bubble and pressure sensing in continuous feeding
Fluidic Connections and Protection for Continuous Feeding
Flow-path protection

ON THIS PAGE

What do these products do in this instrument?Match sensing locations to specific fluidic problemsConnect signals, action windows and recovery conditionsTranslate actual branch conditions into configuration requirementsFeedback and recordsCompare product configurations by the roles on this pageConfirm product roles in actual operationCan dispensing be repeated immediately after bubbles or abnormal pressure are detected?ReferencesRelated guides

01What do these products do in this instrument?

Bubble and pressure detection: signals for recording abnormal feed intervals

Provide bubble or pressure signals at actual feed locations, alongside measured delivery, cumulative material and control records. The process program determines whether to compensate a shortfall and the permitted recovery rate.

ABD provides bubble or liquid-state signals for defined tubing; PDM5 provides pressure information at a defined location. Configure module, position and action window separately; the controller associates affected samples or tasks.

02Match sensing locations to specific fluidic problems

Bubble modules report bubble or liquid state in defined tube segments; pressure modules report pressure at defined positions. Before selecting mounting points, define the phase and abnormality to observe: aspiration, delivery, source depletion or branch-load changes. Associate sensor positions with affected samples, cuvettes or stations.

03Connect signals, action windows and recovery conditions

The same signal may mean different things at different valve positions or operating phases. Record normal ranges and faults with actual liquids, tubing and sequences. The controller combines action timing, confirmed delivery status, volume records and sample identity to pause, review or recover; one pressure change cannot directly identify a blockage location or specific cause. Distinguish measured, estimated and unknown volumes; completion of a command does not prove actual liquid delivery.

04Translate actual branch conditions into configuration requirements

Bubble and pressure detection configuration requirements for continuous feeding
ConditionTo confirm
Installation conditionsSpecify tubing dimensions, liquid, sensing location and branch to observe.
Timing and baselineRecord valve positions, pump actions, normal changes and fault-detection windows.
Abnormality handlingAssociate affected containers with confirmed delivery status and volume records; define conditions for review, continuation or re-execution. Distinguish measured, estimated and unknown volumes; completion of a command does not prove actual liquid delivery.
Operations supported in this instrument
OperationSpecific operating conditions
Feedback and recordsSpecific sensor configuration, location, liquid/tubing, sampling rate, threshold and time window

05Feedback and records

Associate pump commands, measured delivery, abnormal time windows and cumulative material records. Pressure or bubble signals indicate flow-path conditions; process loops such as pH control need corresponding sensors and control programs. The process defines whether and how much to compensate after interrupted feeding and the recovery rate. Do not automatically make up cumulative shortfall alone.

Measure fault detection, false alarms and end-to-end response separately; cover baseline changes with liquid, speed and operating conditions

Normal air segments, viscosity changes and sampling delays may be misclassified. The controller determines task validity; sensors alone do not prove dose or assay results.

06Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
ABD bubble-detection moduleBubble or liquid-state identification in defined tubingValidate detection and false alarms for tubing material, dimensions, medium and action window
PDM5 pressure-detection modulePressure-state monitoring at a defined fluidic locationConfirm range and wetted configuration by model; validate normal baseline and abnormalities separately
  • ABD bubble-detection module
  • PDM5 pressure-detection module

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Feedback and recordsMeasure fault detection, false alarms and end-to-end response separately; cover baseline changes with liquid, speed and operating conditionsNormal air segments, viscosity changes and sampling delays may be misclassified

Record output across the run, replenishment interruptions, first flow after bottle changes and reactor volume balance.

08Can dispensing be repeated immediately after bubbles or abnormal pressure are detected?

First establish whether partial delivery has occurred and which container is affected. Immediate repetition may double-dose it. Act on the actual state and recheck the first cycle after recovery.

Refilling or resetting a single syringe can interrupt supply. Continuous-operation capability and aseptic isolation both require system validation.

References

View references (2)
  1. [1]FOREACH ABD bubble-detection module: configurations and specifications
  2. [2]FOREACH PDM5 pressure-detection module: configurations and specifications

Related guides

  • Back to the continuous feeding fluidics overview

Related Products

ABD bubble-detection module; representative configuration. Select capacity, materials and interfaces for the application.

ABD bubble-detection module

PDM5 pressure-detection module; representative configuration. Select capacity, materials and interfaces for the application.

PDM5 pressure-detection module

Related Technical Articles

Why Do Air Bubbles Delay or Bias Piston Pump Dispensing?

A completed piston stroke does not prove that the intended liquid volume reached the vessel. Bubble compression temporarily stores displacement; expansion can then cause a trailing dispense or affect the next cycle. Locate where bubbles first appear and compare synchronized pressure and individual dispense masses before and after priming.

2026-09-10View Details

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Valveless Metering Pump Selection Guide: FOREACH Models and Applications

To select a valveless metering pump, first define the volume per dose and the time available for dispensing. Then check displacement per revolution, drive speed, wetted materials, backpressure and connections, and verify delivery in the actual fluid path. Neither flow rate alone nor the label ‘metering pump’ is enough to select a model.

2026-09-16View Details

Discuss fluidic configurations for continuous feeding

Provide a fluid-path diagram, actual liquids and pressures in each state. Validate detection and false alarms for the tubing, dimensions, media and action window. Confirm range and wetted configuration by model, then test normal baselines and faults separately against the guide's validation objectives.

Contact an engineer