Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Synthetic biology/Microbioreactors
< Back

Fluidic valves in microbioreactors

Application guide

This page explains fluidic-valve location, coordination and configuration requirements for selecting feeding, sampling and maintenance destinations and isolating flexible-tubing feed/sample branches in microbioreactors, with links to relevant operating and validation tasks.

Application guides

Microbioreactor application guide

Microbioreactor fluidics overview
Syringe pumps in microbioreactors
Sampling
Valveless metering pumps in microbioreactors
Feeding
Diaphragm pumps in microbioreactors
Air-containing waste aspiration and post-maintenance restart
Fluidic valves in microbioreactors
Path isolation
Bubble and pressure detection in microbioreactors
Tubing and Fittings for Microbioreactors

ON THIS PAGE

What do these products do in this instrument?Define connections using the instrument's port-state diagramInclude renewal of shared segments after switching in the sequenceTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageExplore specific operating and validation tasksConfirm product roles in actual operationDo more valve ports mean more channels can supply liquid simultaneously?ReferencesRelated guides

01What do these products do in this instrument?

Multiport Rotary Valves: Routing for Feeding, Sampling and Maintenance

In selector-valve configurations, establish the current task path in coordination with the pump and culture-vessel identity. Specify wash, sampling-discard and waste destinations, and verify isolation when closed.

MRV3 selects sources or destinations and requires a port-state diagram and shared-volume budget. Port count indicates routing options; confirm pressure in each state and independent simultaneous supply requirements separately.

Tubing pinch-off solutions: isolate flexible feed or sampling branches

Control the actual pinch-operated branch with supply and maintenance steps. Confirm wetted and contamination boundaries across tubing, fittings and replacement procedures.

Discuss tubing pinch-off for the specific project. Tubing and fittings define the liquid-contact path. Validate tubing material, wall thickness, pinch seal and replacement procedure together, and assess cleaning or sterilization across the complete path.

02Define connections using the instrument's port-state diagram

This page covers multiport rotary valves and tubing pinch-off solutions. Identify every port, current source, receiving destination and branch requiring isolation. Check connectivity during aspiration, delivery, washing, maintenance and power loss. Valve selection actions must correspond to permitted drive conditions.

03Include renewal of shared segments after switching in the sequence

After source switching, shared tubing may retain the previous composition. Record volume and arrival delay from the new source to the receiver, and measure residue and recovery for the actual worst-case switching combination. Confirm port positioning and arrival of new liquid separately.

04Translate actual branch conditions into configuration requirements

Fluidic-valve configuration for microbioreactors
ConditionTo confirm
Connections and pressureProvide port diagrams and pressure conditions for all operating, cleaning and shutdown states.
Shared volumeIdentify residue locations after source changes, flushing volumes and discharge destinations.
Control and isolationCheck valve-position feedback, pump actions, shutoff leakage and permitted power-off states.
Operations supported in this instrument
OperationSpecific operating conditions
Path isolationAll ports, valve states, pressures in each state, shared volume and flushing volume

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
MRV3 multiport rotary valveMultiple-source selectionCompare 10-, 16- and 24-port options and port diagrams; verify high-pressure suitability separately
  • MRV3 multiport rotary valve

06Explore specific operating and validation tasks

Path isolation

The port-state table must cover feeding, sampling, cleaning and drainage. Check leakage and backflow even in closed states.

  • Path isolation

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Path isolationCheck unintended connections, leakage, backflow and post-switching residue in each state; measure flushing volume and arrival delay through the complete pathMisalignment, shared-segment residue or abnormal switching pressure may affect the next task

Check cumulative feeding, sampling representativeness, volume balance and recovery during long runs.

08Do more valve ports mean more channels can supply liquid simultaneously?

Check port connection structure and drive configuration. The number of selectable sources, independent paths and simultaneous-operation capability are different conditions, determined by actual connections in each state.

Bubble and pressure signals describe fluid-path conditions; they do not directly measure pH, dissolved oxygen or growth. Validate the complete aseptic boundary separately.

References

View references (1)
  1. [1]FOREACH MRV3 multiport rotary valve: configurations and specifications

Related guides

  • Back to microbioreactor fluidics
  • Path isolation

Related Products

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

Related Technical Articles

Rotary Valve Selection Guide: From Fluid Paths to System Validation

Map the connections required at each step before comparing specifications. Use the actual liquids, tubing and switching sequence to validate suitability for your instrument.

2026-09-30View Details

How Does a 6-Port HPLC Injection Valve Work? Load, Inject and Vent

Follow sample loading into an external loop and transfer to the column by the mobile phase, distinguishing the HP valve's main positions and vent path from the factors that determine injection volume.

2026-09-29View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss a microbioreactor fluidic configuration

Provide a fluid diagram, the actual liquids and pressures in each state. Compare 10-, 16- and 24-port configurations against the port map, and assess high-pressure suitability separately. Compare suitable configurations against the validation objectives described here.

Contact an engineer