  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Laboratory automation/Reagent dispensing
< Back

Fluidic valves in reagent dispensing

Application guide

This page explains fluidic valve positions, supporting components and configuration requirements for reagent-source and dispensing-destination selection and outlet control, with links to operating and validation tasks.

Application guides

Reagent dispensing application guide

Fluidic Overview for Reagent Dispensing
Syringe pumps in reagent dispensing
Valveless metering pumps in reagent dispensing
Repeated dispensing
Fluidic valves in reagent dispensing
Bubble and Pressure Monitoring for Reagent Dispensing
Tubing and Fittings for Reagent Dispensing

ON THIS PAGE

What do these products do in this instrument?Define connections using the instrument's port-state diagramInclude renewal of shared segments after switching in the sequenceTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageConfirm product roles in actual operationDo more valve ports mean more channels can supply liquid simultaneously?ReferencesRelated guides

01What do these products do in this instrument?

Multiport Rotary Valves: Selecting Reagent Sources and Dispensing Destinations

Establish the current dispensing connection in multisource or multioutlet configurations, coordinated with drive operation and container records. Treat bottle changes, source switching, priming and shared-volume displacement as separate steps.

MRV3 selects sources or destinations and requires a port-state diagram and shared-volume budget. Port count indicates routing options; confirm pressure in each state and independent simultaneous supply requirements separately.

Solenoid valves: dispensing-outlet shutoff

At outlets using on/off control, coordinate starts and stops with the supply pump and verify the power-off state. Check retained droplets, post-stop dripping and delivered volume at the receiving vessel.

Solenoid valves control branches according to actual ports, flow direction, differential pressure and power-off state. Check opening/closing order with pump commands; inspect shutoff leakage and shared residue separately.

02Define connections using the instrument's port-state diagram

This page covers multiport rotary and solenoid valves. Mark each port, current source, receiver and isolated branch, checking connections during aspiration, delivery, cleaning, maintenance and power loss. Valve selection must match conditions permitting drive actions.

03Include renewal of shared segments after switching in the sequence

After source switching, shared tubing may retain the previous composition. Record volume and arrival delay from the new source to the receiver, and measure residue and recovery for the actual worst-case switching combination. Confirm port positioning and arrival of new liquid separately.

04Translate actual branch conditions into configuration requirements

Fluidic-valve configuration requirements for reagent dispensing
ConditionTo confirm
Connections and pressureProvide port diagrams and pressure conditions for all operating, cleaning and shutdown states.
Shared volumeIdentify residue locations after source changes, flushing volumes and discharge destinations.
Control and isolationCheck valve-position feedback, pump actions, shutoff leakage and permitted power-off states.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
MRV3 multiport rotary valveMultiple-source selectionCompare 10-, 16- and 24-port options and port diagrams; verify high-pressure suitability separately
SV10 solenoid valveOn/off control or branch selectionCheck normal state, differential pressure, flow direction and duty cycle; high-pressure tasks require a separately suitable configuration
  • MRV3 multiport rotary valve
  • SV10 solenoid valve

06Confirm product roles in actual operation

Include first, middle and last batch doses, recovery after bottle changes, and extended operation with the actual medium.

07Do more valve ports mean more channels can supply liquid simultaneously?

Check port connection structure and drive configuration. The number of selectable sources, independent paths and simultaneous-operation capability are different conditions, determined by actual connections in each state.

Repeated dosing and continuous supply are different modes. Valveless metering also requires validation with the actual medium and operating conditions.

References

View references (2)
  1. [1]FOREACH MRV3 multiport rotary valve: configurations and specifications
  2. [2]FOREACH SV10 solenoid valve: configurations and specifications

Related guides

  • Back to reagent dispensing fluidics

Related Products

MRV3 multiport rotary valve; representative configuration. Select capacity, materials and interfaces for the application.

MRV3 multiport rotary valve

SV10 solenoid valve; representative configuration. Select capacity, materials and interfaces for the application.

SV10 solenoid valve

Related Technical Articles

Rotary Valve Selection Guide: From Fluid Paths to System Validation

Map the connections required at each step before comparing specifications. Use the actual liquids, tubing and switching sequence to validate suitability for your instrument.

2026-09-30View Details

How Does a 6-Port HPLC Injection Valve Work? Load, Inject and Vent

Follow sample loading into an external loop and transfer to the column by the mobile phase, distinguishing the HP valve's main positions and vent path from the factors that determine injection volume.

2026-09-29View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss a reagent dispensing fluidic configuration

Provide a fluidic diagram, actual liquids and pressures in each operating state. Compare 10-, 16- and 24-port options using port diagrams, and verify high-pressure suitability separately. Check normal state, differential pressure, flow direction and energization cycle. Select a separately suitable configuration for high-pressure tasks. Assess configurations against this guide's validation objectives.

Contact an engineer