Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Laboratory automation/Reagent dispensing
< Back

Valveless metering pumps in reagent dispensing

Application guide

This page explains the valveless metering pump's position, supporting components and configuration requirements for suitable repeated-dose or continuous reagent supply, with links to operating and validation tasks.

Application guides

Reagent dispensing application guide

Fluidic Overview for Reagent Dispensing
Syringe pumps in reagent dispensing
Valveless metering pumps in reagent dispensing
Repeated dispensing
Fluidic valves in reagent dispensing
Bubble and Pressure Monitoring for Reagent Dispensing
Tubing and Fittings for Reagent Dispensing

ON THIS PAGE

What do these products do in this instrument?Distinguish repeated dosing from continuous supply firstHandle starts/stops, replenishment and two-stream merging separatelyTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageExplore specific operating and validation tasksConfirm product roles in actual operationCan the same configuration be retained after changing the target dose or time window?ReferencesRelated guides

01What do these products do in this instrument?

Valveless Metering Pumps: Repeated Doses or Continuous Supply in Suitable Configurations

Provide repeated or continuous output to dispensing branches within permitted formulation and load conditions, coordinated with starts/stops and vessel timing. Check dose, flow within time windows and cumulative volume separately.

Compare RPL-series options for repeated metering or auxiliary continuous supply according to the task. Confirm individual dose, flow over the operating time window and cumulative volume separately. For proportioning, also compare the liquid actually arriving from each of the two paths.

02Distinguish repeated dosing from continuous supply first

Compare valveless metering pumps for repeated dosing or auxiliary continuous supply in suitable configurations. Repeated dosing requires assessment of individual deliveries and liquid released after stopping; continuous tasks require time-window flow and cumulative volume. After converting the rotation program to a set volume, measure the actual received volume under the installed flow-path and load conditions.

03Handle starts/stops, replenishment and two-stream merging separately

Starting, stopping and bottle changes affect actual arrival. Record initial liquid delivery, recovery delay and terminal drips. For two-stream proportioning, check each path's load and arrival time before checking the composition and mixing after the junction. A matching cumulative ratio does not replace composition validation during startup and within each operating time window.

04Translate actual branch conditions into configuration requirements

Valveless Metering Pump Configuration for Reagent Dispensing
ConditionTo confirm
Output requirementsDefine individual dose or target flow, duration, cumulative volume and allowable interruptions.
Installed loadSpecify medium, inlet conditions, outlet backpressure and downstream connections.
Start-stop behavior and proportioningMeasure initial, steady-state and restart output. For two-stream tasks, also check actual arrival and mixing results.
Operations supported in this instrument
OperationSpecific operating conditions
Repeated dispensingDose, count, first and last doses, retained volume and recovery after replenishment

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
RPL Valveless Metering PumpSuitable repeated or continuous meteringCompare displacement, speed, actual backpressure and starts/stops; check two-stream ratios separately
  • RPL Valveless Metering Pump

06Explore specific operating and validation tasks

Repeated dispensing

Compare cycle volume with usable capacity to calculate refill frequency and lost time. Evaluate valveless candidates by displacement per revolution, speed and actual output after starts and stops.

  • Repeated dispensing

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Repeated dispensingUse actual media to check first, middle and last doses and delivery after bottle changes; confirm received volume and timing rather than substituting commanded steps for volumeEmpty sources, bubbles, nozzle droplets and backpressure changes affect first or last doses

Include first, middle and last batch doses, recovery after bottle changes, and extended operation with the actual medium.

08Can the same configuration be retained after changing the target dose or time window?

Validate starts/stops, operating increments and receiver-end drips under the new actual load. Measure repeated dispensing dose by dose; for continuous supply, measure output within operating time windows and cumulatively. Then determine whether the existing configuration and program still meet requirements.

Repeated dosing and continuous supply are different modes. Valveless metering also requires validation with the actual medium and operating conditions.

References

View references (1)
  1. [1]FOREACH RPL valveless metering pumps: configurations and specifications

Related guides

  • Back to reagent dispensing fluidics
  • Repeated dispensing

Related Products

RPL Valveless Metering Pump; representative configuration. Select capacity, materials and interfaces for the application.

RPL Valveless Metering Pump

Related Technical Articles

What Is a Valveless Metering Pump? Working Principle, Applications and Selection

A valveless metering pump is a positive-displacement pump that combines rotary and axial reciprocating piston motion to switch the fluid path, draw liquid in and discharge it. Its pumping mechanism does not rely on conventional inlet and outlet check valves. It can serve reagent dispensing, titration, filling and two-fluid proportional delivery, but metering performance still has to be verified with the actual fluid, pressure, tubing, drive and cleaning conditions.

2026-09-21View Details

Valveless Metering Pump Selection Guide: FOREACH Models and Applications

To select a valveless metering pump, first define the volume per dose and the time available for dispensing. Then check displacement per revolution, drive speed, wetted materials, backpressure and connections, and verify delivery in the actual fluid path. Neither flow rate alone nor the label ‘metering pump’ is enough to select a model.

2026-09-16View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss a reagent dispensing fluidic configuration

Provide a fluidic diagram, actual liquids and pressures in each operating state. Compare displacement, speed, actual backpressure and start-stop behavior; verify dual-stream ratios separately. Assess suitable configurations against this guide's validation objectives.

Contact an engineer