What do these products do in this instrument?
Valveless metering pumps: suitable continuous auxiliary liquid supply
Provide repeated or continuous metering in instrument-compatible auxiliary branches, accounting for actual introduction-end load. Confirm suitability for the matrix, pressure and signal recovery. Replacing the original introduction configuration requires complete-path validation.
Compare RPL-series options for repeated metering or auxiliary continuous supply according to the task. Confirm individual dose, flow over the operating time window and cumulative volume separately. For proportioning, also compare the liquid actually arriving from each of the two paths.
Distinguish repeated dosing from continuous supply first
Compare valveless metering pumps for repeated dosing or auxiliary continuous supply in suitable configurations. Repeated dosing requires assessment of individual deliveries and liquid released after stopping; continuous tasks require time-window flow and cumulative volume. After converting the rotation program to a set volume, measure the actual received volume under the installed flow-path and load conditions.
Handle starts/stops, replenishment and two-stream merging separately
Starting, stopping and bottle changes affect actual arrival. Record initial liquid delivery, recovery delay and terminal drips. For two-stream proportioning, check each path's load and arrival time before checking the composition and mixing after the junction. A matching cumulative ratio does not replace composition validation during startup and within each operating time window.
Translate actual branch conditions into configuration requirements
| Condition | To confirm |
|---|---|
| Output requirements | Define individual dose or target flow, duration, cumulative volume and allowable interruptions. |
| Installed load | Specify medium, inlet conditions, outlet backpressure and downstream connections. |
| Start-stop behavior and proportioning | Measure initial, steady-state and restart output. For two-stream tasks, also check actual arrival and mixing results. |
Compare product configurations by the roles on this page
| Product | Configuration option | Conditions to verify |
|---|---|---|
| RPL Valveless Metering Pump | Suitable repeated or continuous metering | Compare displacement, speed, actual backpressure and starts/stops; check two-stream ratios separately |
Confirm product roles in actual operation
Check concentration ratios, mixing, blank recovery and method results. Evaluate preparation and sample supply separately.
Can the same configuration be retained after changing the target dose or time window?
Validate starts/stops, operating increments and receiver-end drips under the new actual load. Measure repeated dispensing dose by dose; for continuous supply, measure output within operating time windows and cumulatively. Then determine whether the existing configuration and program still meet requirements.
A sample-preparation pump is not automatically suitable for nebulizer supply. Confirm the introduction system for the specific instrument.