Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Analytical instruments/Spectroscopy and elemental analysis
< Back

Tubing and fittings in spectroscopy and elemental analysis

Application guide

Explore tubing and fitting placement, coordination and configuration between sample matrices and instrument interfaces in spectroscopy and elemental analysis, with links to operating and validation tasks.

Applicable architecture

This guide covers liquid-sample elemental analysis and auxiliary fluidics. Solid, gas and other spectroscopic architectures require separate assessment of their introduction devices. Flow or capacity alone does not qualify these candidates as replacements for the original sample-introduction system.

Application guides

Spectroscopy and elemental analysis application guide

Spectroscopy and elemental-analysis fluidics overview
Syringe pumps in spectroscopy and elemental analysis
Discrete liquid-sample transfer and introduction conditionsStandards and dilution
Valveless Metering Pumps for Spectroscopy and Elemental Analysis
Multiport rotary valves in spectroscopy and elemental analysis
Multiple-source selection
Sampling needles in spectroscopy and elemental analysis
Bubble and Pressure Monitoring for Spectroscopy and Elemental Analysis
Tubing and fittings in spectroscopy and elemental analysis

ON THIS PAGE

What do these products do in this instrument?Design tubing and fittings as a complete wetted pathCalculate connection volume and post-maintenance recoveryTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageRelated operations and architecture comparisonsConfirm product roles in actual operationDoes a fitting that tightens prove the tubing assembly is suitable?ReferencesRelated guides

01What do these products do in this instrument?

Tubing and fittings: connecting sample matrices to instrument interfaces

Build the actual path traversed by samples, standards and blanks. Check materials for acid/salt matrices and pressure locations. Coordinate tubing length, shared volume and installed signal arrival with the method.

Tubing and fittings together form sealed connections and the actual transfer path. Check formulation, inner/outer diameters, length, tube-end positioning and port geometry, including added volume in residue and arrival delay.

02Design tubing and fittings as a complete wetted path

Tubing, fittings and ports jointly determine sealing, transfer volume and medium-contact coverage. Materials and dimensions must suit formulation, operating conditions and installation. Include tubing length and interface volume in priming, shared residue and arrival delay. After connection changes, recheck delivery and cleaning through the actual path.

03Calculate connection volume and post-maintenance recovery

Shared volume affects liquid arrival and flushing; interface gaps may retain the previous composition. Record length, actual bore and tube insertion position. After disassembly, reprime and check seals, then compare first-cycle delivery, blanks or recovered product to confirm path recovery.

04Translate actual branch conditions into configuration requirements

Tubing and fitting configuration for spectroscopy and elemental analysis
ConditionTo confirm
Materials and assemblyProvide formulation, tubing inner/outer diameters, length, fitting structure and port fit.
Volume and loadCalculate shared and replacement-component added volumes; measure actual flow and response.
Maintenance recoveryRecord disassembly locations and added volume; recheck priming, sealing and first-cycle received results.
Operations supported in this instrument
OperationSpecific operating conditions
Discrete liquid-sample transfer and introduction conditionsActual sample volume, remaining source volume, probe-tip height, aspiration/dispensing speed and system liquid

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
Tubing materials and dimensionsConnection paths and shared volumeBore, length, load and actual formulation jointly determine materials and dimensions
Rigid-tubing fittingsTube-end positioning and sealed connectionsCheck tube outer diameter, threads, seal structure and port-bottom geometry
  • Tubing materials and dimensions
  • Rigid-tubing fittings

06Related operations and architecture comparisons

Discrete liquid-sample transfer and introduction conditions

Delivery to a dilution vessel primarily requires volume control; delivery to an introduction interface also requires system-specific continuous flow, pulsation and pressure checks. Evaluate materials and sample-change recovery using the actual matrix.

  • Discrete liquid-sample transfer and introduction conditions

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Discrete liquid-sample transfer and introduction conditionsMeasure actual delivery at the receiver, covering routine small volumes and maximum task volume, first dose after idle, sample changes and high/low concentration sequencesAir aspiration, clots/particles, probe contact with a wall or leakage alter actual delivery

Check concentration ratios, mixing, blank recovery and method results. Evaluate preparation and sample supply separately.

08Does a fitting that tightens prove the tubing assembly is suitable?

Also confirm port geometry, tube-end positioning and seal fit. Check leakage, hold-up and performance after repeated maintenance under actual conditions; thread engagement alone is insufficient.

A sample-preparation pump is not automatically suitable for nebulizer supply. Confirm the introduction system for the specific instrument.

References

View references (2)
  1. [1]FOREACH tubing materials and dimensions: configurations and specifications
  2. [2]FOREACH rigid-tubing fittings: configurations and specifications

Related guides

  • Return to the spectroscopy and elemental-analysis overview

Related Products

Tubing materials and dimensions; representative configuration. Select capacity, materials and interfaces for the application.

Tubing materials and dimensions

Rigid-tubing fittings; representative configuration. Select capacity, materials and interfaces for the application.

Rigid-tubing fittings

Related Technical Articles

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Why Does Actual Flow Change So Much When the Tubing Size Changes on the Same Miniature Diaphragm Pump?

Even when the pump is unchanged, installed flow can change because of tubing inner diameter, length, bends, and the minimum bore of fittings. When flow falls after a tubing change, the effective response is neither to blame the pump first nor to enlarge every tube indiscriminately. Measure inlet pressure, outlet pressure, and accumulated flow together to determine where the added restriction actually occurs.

2026-08-24View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss fluidic configurations for elemental analysis of liquid samples

Provide a fluid diagram, the actual liquids and pressures in each state. Bore size, length, load and actual formulation jointly determine material and dimensional choices. Check tubing OD, threads, sealing structure and port-bottom geometry. Compare suitable configurations against the validation objectives described here.

Contact an engineer