Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Analytical instruments/Spectroscopy and elemental analysis
< Back

Spectroscopy and elemental analysis: standards and dilution

Application guide

Standards and dilution are specific liquid-handling operations in spectroscopy and elemental analysis. This page explains component roles, action sequence, actual operating conditions and recovery requirements. Establish the architecture before comparing configurations.

Applicable architecture

This guide covers liquid-sample elemental analysis and auxiliary fluidics. Solid, gas and other spectroscopic architectures require separate assessment of their introduction devices. Flow or capacity alone does not qualify these candidates as replacements for the original sample-introduction system.

Application guides

Spectroscopy and elemental analysis application guide

Spectroscopy and elemental-analysis fluidics overview
Syringe pumps in spectroscopy and elemental analysis
Discrete liquid-sample transfer and introduction conditionsStandards and dilution
Valveless Metering Pumps for Spectroscopy and Elemental Analysis
Multiport rotary valves in spectroscopy and elemental analysis
Multiple-source selection
Sampling needles in spectroscopy and elemental analysis
Bubble and Pressure Monitoring for Spectroscopy and Elemental Analysis
Tubing and fittings in spectroscopy and elemental analysis

ON THIS PAGE

Where standards and dilution occur in the instrumentProduct responsibilities in this operationOrganize the sequence by actual architectureDefine operating conditions for this taskCompare product configurations by the roles on this pageValidate operation results at the receiverLocate abnormalities and restore the next operationReferencesRelated guides

01Where standards and dilution occur in the instrument

Provide separate paths as needed for standards, over-range dilution, internal standards and continuous auxiliary reagents. Verify concentration and mixing from actual delivered sample and reagent volumes. The method determines whether continuous supply is required.

Measure delivery of stock, diluent and internal standard separately, then validate the resulting concentration or method response after mixing. Shared-section residue can produce an incorrect composition despite correct commanded volumes.

02Product responsibilities in this operation

Syringe drive and valve positions jointly organize aspiration, holding and dispensing. Record working volume, remaining inventory and replenishment timing according to the sequence.

For spectroscopy and elemental analysis, confirm actual sample, diluent or internal-standard volumes, concentrations at each stage, mixing and secondary-sampling conditions.

03Organize the sequence by actual architecture

  1. List stock, diluent and internal-standard sources, target concentrations and working volumes according to the method. Specify receiving locations and mixing methods.
  2. Deliver each liquid through the source-selection and syringe aspiration/dispense sequence. Record actual receipt and the effect of shared-path flushing on composition.
  3. After mixing, check actual ratio, concentration or method response, including low-range preparation, overrange dilution and the first liquid after source changes.
  4. Confirm washing and blank recovery for the actual matrix. If the method requires continuous internal-standard or auxiliary-liquid addition, configure that branch separately for continuous flow and merging conditions.

04Define operating conditions for this task

Conditions, results and abnormality records for this operation
To defineDetails
Actual operating conditionsActual volumes of original sample, diluent or internal standard; concentrations at each stage; mixing and resampling conditions
Acceptance targetMeasure each branch's delivery, received ratio and mixing uniformity separately, then check assay response
Fault localizationSmall-volume errors, shared residual liquid or inadequate mixing may alter the actual ratio

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
HLD rotary-valve syringe pumpAspiration, holding and dispensing with a rotary valveCheck source/outlet valve positions, capacity budget and replenishment timing
HMD solenoid-valve syringe pumpMetered aspiration and dispensing with solenoid valvesCheck open/closed and power-off states, working volume and replenishment cycle
  • HLD rotary-valve syringe pump
  • HMD solenoid-valve syringe pump

06Validate operation results at the receiver

Measure each branch's delivery, received ratio and mixing uniformity separately, then check assay response.

Check concentration ratios, mixing, blank recovery and method results. Evaluate preparation and sample supply separately.

07Locate abnormalities and restore the next operation

Small-volume errors, shared residue or insufficient mixing may change the actual ratio.

Review actual results of affected steps before resuming the next action.

A sample-preparation pump is not automatically suitable for nebulizer supply. Confirm the introduction system for the specific instrument.

References

View references (2)
  1. [1]FOREACH HLD rotary-valve syringe pump: configurations and specifications
  2. [2]FOREACH HMD solenoid-valve syringe pump: configurations and specifications

Related guides

  • Return to the spectroscopy and elemental-analysis overview
  • Syringe pumps in spectroscopy and elemental analysis
  • Discrete liquid-sample transfer and introduction conditions

Related Products

HLD rotary-valve syringe pump; representative configuration. Select capacity, materials and interfaces for the application.

HLD rotary-valve syringe pump

HMD solenoid-valve syringe pump; representative configuration. Select capacity, materials and interfaces for the application.

HMD solenoid-valve syringe pump

Related Technical Articles

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

What Is Pipetting? Manual and Automated Workflows Compared

Pipetting is the transfer of a specified volume of liquid from one location to another. Examples include moving 100 µL from a sample tube into a reaction vessel, or adding sample and diluent in a defined ratio.

2026-09-29View Details

Discuss fluidic configurations for elemental analysis of liquid samples

Provide a fluid-path diagram, actual liquids and pressures in every state. Specify source and outlet valve positions, capacity budgets and refill timing, including open, closed and power-off states, working volumes and replenishment cycles. Compare configurations against the validation objectives in this guide.