Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Analytical instruments/Water analysis units
< Back

Tubing connections and protection in water analysis units

Application guide

This page explains the location, coordination and configuration requirements of tubing connections and protective components for method-permitted water-sample/component protection and in-cabinet wetted/reaction paths in water analysis units, with links to relevant operating and validation tasks.

Application guides

Water-Quality Analysis Unit Guide

Water-analysis unit fluidics overview
Piston Pumps for Water-Quality Analysis Units
Sample meteringMetered reagent addition and reaction timing
Syringe pumps in water analysis units
Diaphragm Pumps for Water-Quality Analysis Units
Multiport rotary valves in water-analysis units
Bubble and pressure detection in water analysis units
Tubing connections and protection in water analysis units
Protective filtration

ON THIS PAGE

What do these products do in this instrument?Design tubing and fittings as a complete wetted pathCheck analyte retention while protecting componentsTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageExplore specific operating and validation tasksConfirm product roles in actual operationDoes a fitting that tightens prove the tubing assembly is suitable?ReferencesRelated guides

01What do these products do in this instrument?

Filters: method-permitted water-sample treatment or component protection

Remove particles only at method-permitted locations, consistent with the defined analyte and downstream metering. Check targets before and after filtration, pressure drop, blanks and the first sample after replacement separately.

Filters provide method-permitted particle retention or component protection. Target components, pore size and filter material guide selection. Assess pressure drop, adsorption and recovery after replacement in the actual path.

Tubing and fittings: in-cabinet wetted and reaction-path connections

Connect incoming water samples, reagent sources and reaction positions, identifying shared sections and waste destinations. Recheck materials, tubing length and maintenance replacements together with actual delivery and the first reaction after restart.

Tubing and fittings together form sealed connections and the actual transfer path. Check formulation, inner/outer diameters, length, tube-end positioning and port geometry, including added volume in residue and arrival delay.

02Design tubing and fittings as a complete wetted path

Tubing, fittings and ports jointly determine sealing, transfer volume and medium-contact coverage. Materials and dimensions must suit formulation, operating conditions and installation. Include tubing length and interface volume in priming, shared residue and arrival delay. After connection changes, recheck delivery and cleaning through the actual path.

03Check analyte retention while protecting components

Filters provide method-permitted particle retention or component protection. With actual samples and filter materials, check adsorption, blanks, pressure drop and flow changes as loading accumulates, while measuring analyte recovery. The specific method must validate whether the filtrate remains suitable for analysis.

04Translate actual branch conditions into configuration requirements

Tubing connection and protection configuration requirements for water analysis units
ConditionTo confirm
Materials and assemblyProvide formulation, tubing inner/outer diameters, length, fitting structure and port fit.
Volume and loadCalculate shared and replacement-component added volumes; measure actual flow and response.
Filtration and method requirementsConfirm filter material and pore size. Compare analyte recovery, blanks and pressure drop before and after fouling, and record recovery after replacement.
Operations supported in this instrument
OperationSpecific operating conditions
Protective filtrationAnalytical target, filter material/pore size, filtration location, added volume, actual pressure drop and permitted maintenance

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
PE-Series FiltersParticle retention permitted by the methodCards show representative configurations. Select actual pore size and filter material for the target, pressure drop and recovery requirements.
Tubing materials and dimensionsConnection paths and shared volumeBore, length, load and actual formulation jointly determine materials and dimensions
Rigid-tubing fittingsTube-end positioning and sealed connectionsCheck tube outer diameter, threads, seal structure and port-bottom geometry
  • PE-Series Filters
  • Tubing materials and dimensions
  • Rigid-tubing fittings

06Explore specific operating and validation tasks

Protective filtration

Filtration can reduce particle entry into components while also changing the measured sample. Assess adsorption, retention, pressure drop and recovery after replacement. Method acceptability takes priority over mechanical protection.

  • Protective filtration

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Protective filtrationCompare analytes, recovery and blanks before and after filtration. Check pressure drop and actual flow after loading accumulates, and the first sample after replacement.Blockage, adsorption, leakage or added filter-assembly volume can change the sample and its arrival time.

Assess dose, reaction, blanks and recovery according to the method, and verify what is measured after filtration.

08Does a fitting that tightens prove the tubing assembly is suitable?

Also confirm port geometry, tube-end positioning and seal fit. Check leakage, hold-up and performance after repeated maintenance under actual conditions; thread engagement alone is insufficient.

Validate field representativeness and internal metering separately. Filtration intended to protect components must still meet method requirements.

References

View references (3)
  1. [1]FOREACH PE series filters: configurations and specifications
  2. [2]FOREACH tubing materials and dimensions: configurations and specifications
  3. [3]FOREACH rigid-tubing fittings: configurations and specifications

Related guides

  • Back to the water analysis unit fluidics overview
  • Protective filtration

Related Products

PE-Series Filters; representative configuration. Select capacity, materials and interfaces for the application.

PE-Series Filters

Tubing materials and dimensions; representative configuration. Select capacity, materials and interfaces for the application.

Tubing materials and dimensions

Rigid-tubing fittings; representative configuration. Select capacity, materials and interfaces for the application.

Rigid-tubing fittings

Related Technical Articles

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Why Does Actual Flow Change So Much When the Tubing Size Changes on the Same Miniature Diaphragm Pump?

Even when the pump is unchanged, installed flow can change because of tubing inner diameter, length, bends, and the minimum bore of fittings. When flow falls after a tubing change, the effective response is neither to blame the pump first nor to enlarge every tube indiscriminately. Measure inlet pressure, outlet pressure, and accumulated flow together to determine where the added restriction actually occurs.

2026-08-24View Details

Piston Pump Accuracy, Repeatability and Resolution Explained

Learn why theoretical volume per step is not the minimum reliable dose, and how accuracy, repeatability, valves, bubbles and working stroke affect dispensing results.

2026-09-06View Details

Discuss fluidic configurations for water analysis units

Provide a fluidic diagram, actual liquids and pressures in each operating state. Cards show representative configurations; choose actual pore size and filter material for the analyte, pressure drop and recovery. Select tubing material and dimensions using bore, length, load and formulation. Check OD, threads, sealing structure and port-bottom geometry. Compare configurations against this guide's validation objectives.

Contact an engineer