What do these products do in this instrument?
Syringe pumps: individual feeding and sample metering
Drive replenishment or sample transfer in discrete operations, coordinated with sources, receiving vessels and feeding times. Include sampling and path-renewal discard in process volume records.
HLD and HMD organize aspiration/dispensing paths with rotary and solenoid valves respectively. Capacity budgets include useful volume, holding stages and replenishment points; valve states and pump actions together create each delivery.
Organize syringe metering around aspiration, holding and dispensing
Syringe drives use controlled displacement for aspiration, holding and dispensing. With direct contact, source liquid enters the metering chamber; with system-liquid drive, sample can remain at the probe tip or a designated tube segment. Define wetted coverage before capacity, cleaning and replenishment. For repeated dispensing, track current inventory, delivered volume and next replenishment time.
Map valve connections to every action
Check port connections, opening/closing sequence and power-off state separately for rotary- and solenoid-valve configurations. Changing source does not automatically remove old liquid from the chamber or shared tubing. Plan flushing for formulation and residue requirements, then evaluate the first dose after switching and dose-to-dose variation.
Translate actual branch conditions into configuration requirements
| Condition | To confirm |
|---|---|
| Stored volume and timing | Define volume per operation, consecutive dispensing count, holding time and permitted replenishment window. |
| Valve positions and destinations | Provide a source, receiver and waste port diagram with open/closed and power-off states. |
| Liquid changes and first dose | Check shared residue, priming destination and actual received volume after standby or source changes. |
| Operation | Specific operating conditions |
|---|---|
| Online sampling | Analyte, sampling interval, renewal of stagnant sections, discard-volume budget and permitted pretreatment |
Compare product configurations by the roles on this page
| Product | Configuration option | Conditions to verify |
|---|---|---|
| HLD rotary-valve syringe pump | Aspiration, holding and dispensing with a rotary valve | Check source/outlet valve positions, capacity budget and replenishment timing |
| HMD solenoid-valve syringe pump | Metered aspiration and dispensing with solenoid valves | Check open/closed and power-off states, working volume and replenishment cycle |
Explore specific operating and validation tasks
Online sampling
The stagnant section between the sampling port and receiver needs refreshing, but discarded liquid consumes process volume. Define the analytical objective and sampling budget together.
Confirm product roles in actual operation
| Operation | Measurements and observations | Priority checks |
|---|---|---|
| Online sampling | Measure renewal time at the analytical or receiving interface and assess target representativeness using paired samples | Old-sample mixing, settling, adsorption or insufficient renewal time can make the sample unrepresentative of its source. |
Connect the culture process, actual feeding and sample analysis, retaining records across the entire run.
For repeated dispensing from one chamber, is checking total volume enough?
Measure each received dose, especially the first and last. Even when total volume is near target, individual errors may differ. Relate replenishment, valve switching and receiving actions to each result.
Periodic dispensing, continuous feeding and aseptic sampling have different requirements. A single metering test cannot establish all three.