Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Synthetic biology/Biofoundry Construct Development and Screening
< Back

Diaphragm Pumps for Biofoundry Construct Development and Screening

Application guide

This page explains diaphragm-pump location, coordination and configuration requirements for actual shared wash stations and auxiliary supply in Biofoundry construction and screening, with links to relevant operating and validation tasks.

Application guides

Biofoundry construction and screening application guide

Biofoundry construction and screening fluidics overview
Syringe Pumps for Biofoundry Construct Development and Screening
Biological-reagent aspiration and dispensing
Air-Displacement Pipetting Pumps for Biofoundry Construct Development and Screening
Disposable-tip pipetting of construct samplesPer-well delivery for screening plates
Diaphragm Pumps for Biofoundry Construct Development and Screening
Multiport rotary valves in Biofoundry construction and screening
Path scheduling
Bubble and Pressure Monitoring for Biofoundry Construct Development and Screening
Tubing and Fittings for Biofoundry Construct Development and Screening

ON THIS PAGE

What do these products do in this instrument?Assign liquid supply to a defined usage branchCoordinate supply windows with downstream receiving conditionsTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageConfirm product roles in actual operationDo similar nominal supply- and waste-pump flow rates make a matched pair?ReferencesRelated guides

01What do these products do in this instrument?

Liquid Diaphragm Pumps: Shared Wash Stations and Auxiliary Supply

Deliver working liquid to shared wash stations or auxiliary reservoir branches present in the configuration, coordinated with plate stations and task scheduling. Validate biological-reagent dispensing and shared supply separately.

Compare DPL30, DPL60 and DPL30H by actual supply load. Wash-head, valve, tubing and container resistance jointly determine installed flow; check the supply window and receiving position together.

02Assign liquid supply to a defined usage branch

This page compares liquid diaphragm-pump configurations for suitable supply paths. Define source, point of use, working liquid and cycle time, then measure liquid arriving at the use point under actual load. Cleaning effectiveness also depends on formulation, coverage and contact time.

03Coordinate supply windows with downstream receiving conditions

Tubing, valves and end-use resistance change installed flow. Match supply to permitted container levels or cleaning inflow. Downstream drainage uses its own extraction architecture; check its media and container protection separately rather than inferring them from supply-pump capacity.

04Translate actual branch conditions into configuration requirements

Diaphragm Pump Configuration for Biofoundry Construct Development and Screening
ConditionTo confirm
Inlet mediumDistinguish liquid-only flow, intermittent gas entrainment and foam, and confirm the aspiration modes permitted by the configuration.
Tubing and containersProvide suction lift, outlet load, tubing and waste-container conditions.
Actual supply and removalMeasure incoming liquid, residue and emptying at the station; check handling after full level, shortage or blockage.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
DPL30 liquid diaphragm pumpLiquid supply or auxiliary circulationSelect by installed resistance, actual wash or working fluid and task window
DPL60 liquid diaphragm pumpLiquid supply or auxiliary circulationJudge by peak demand and installed operating point, not free flow alone
DPL30H high-backpressure liquid diaphragm pumpLiquid branches requiring higher backpressure capabilityCalculate pressure budget and actual flow first, then confirm interfaces and materials
  • DPL30 liquid diaphragm pump
  • DPL60 liquid diaphragm pump
  • DPL30H high-backpressure liquid diaphragm pump

06Confirm product roles in actual operation

Assess per-well delivery, identity traceability and construct-development or screening results together.

07Do similar nominal supply- and waste-pump flow rates make a matched pair?

Compare peak inflow, effective aspiration and permissible accumulation in the actual installation. The branches may handle different media and operating windows; validate station recovery over the complete sequence.

High throughput and multiple channels do not establish valid experimental results. See laboratory automation for shared workstation architecture.

References

View references (3)
  1. [1]FOREACH DPL30 liquid diaphragm pump: configurations and specifications
  2. [2]FOREACH DPL60 liquid diaphragm pump: configurations and specifications
  3. [3]FOREACH DPL30H high-backpressure liquid diaphragm pump: configurations and specifications

Related guides

  • Back to Biofoundry construction and screening fluidics

Related Products

DPL30 liquid diaphragm pump; representative configuration. Select capacity, materials and interfaces for the application.

DPL30 liquid diaphragm pump

DPL60 liquid diaphragm pump; representative configuration. Select capacity, materials and interfaces for the application.

DPL60 liquid diaphragm pump

DPL30H high-backpressure liquid diaphragm pump; representative configuration. Select capacity, materials and interfaces for the application.

DPL30H high-backpressure liquid diaphragm pump

Related Technical Articles

How to Read a Diaphragm Pump Flow-Pressure Curve—and Predict Installed Flow

A catalogue value such as 300 or 600 mL/min is not a fixed flow rate inside an instrument. The useful engineering question is: at the actual inlet pressure, outlet backpressure, fluid, tubing and supply voltage, where will the pump and the fluidic circuit settle?

2026-07-28View Details

Selecting a Self-Priming Miniature Liquid Diaphragm Pump: Lift, Priming Time and Dry or Wet Starts

Select a self-priming miniature liquid diaphragm pump by checking suction lift, time to first liquid, dry and wet starting conditions, and stable delivery. Use DPL30, DPL60 and DPL30H specifications to define an instrument-level test.

2026-09-07View Details

What is a programmable automatic air-displacement pipetting pump?

A programmable automatic air-displacement pipetting pump is a liquid-handling component whose aspiration, dispense, speeds and sequence are set through control commands. This article focuses on air-displacement modules that use disposable tips in OEM instruments, with FOREACH SMTP2 as an example of operation, monitoring and selection limits.

2026-09-28View Details

Discuss a biofoundry fluidic configuration

Provide a fluid-path diagram, actual liquids and pressures in each state. Select for installed resistance, actual wash or working liquid and the task window. Assess peak demand and installed operating points, not free flow alone. Calculate pressure budgets and actual flow before confirming interfaces and materials, using the validation objectives in this guide.

Contact an engineer