Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Synthetic biology/Online sampling
< Back

Online Sampling: Filtration

Application guide

This guide covers filtration in online sampling: component roles, action sequence, operating conditions and restart requirements. Identify the architecture before comparing configurations.

Application guides

Online Sampling Guide

Online sampling fluidics overview
Syringe pumps in online sampling
Sample collectionPretreatment
Fluidic Valves for Online Sampling
Flexible-tube control
Bubble and pressure detection in online sampling
Fluidic Connections and Protection for Online Sampling
Filtration

ON THIS PAGE

Where filtration occurs in the instrumentProduct responsibilities in this operationOrganize the sequence by actual architectureDefine operating conditions for this taskCompare product configurations by the roles on this pageValidate operation results at the receiverLocate abnormalities and restore the next operationReferencesRelated guides

01Where filtration occurs in the instrument

Biomass or cell measurements have different filtration requirements from dissolved-metabolite measurements. Retain or remove particles according to the target, and evaluate filter adsorption, increasing pressure drop and sample bias after replacement.

Filter adsorption, increasing pressure drop and replacement can change a sample. Record method-specified particle treatment and before/after filtration differences.

02Product responsibilities in this operation

Tubing, fittings and the protection components described here form the actual path. Validate materials, passage dimensions, connection volume and maintenance state with this operation.

For online sampling, define the analytical target, filter material and pore size, filtration location, added volume, actual pressure drop and permitted maintenance.

03Organize the sequence by actual architecture

  1. Determine whether filtration is permitted for the analytical target. Specify the cells, biomass or liquid-phase components to retain and the treatment location separately.
  2. Confirm filter material and conditions for the method. Compare analytes and actual passed volume before and after filtration, checking adsorption and pressure-drop changes.
  3. After replacement or maintenance, recheck blanks, the first sample and representativeness. Blockage prevention alone does not establish sampling performance.

04Define operating conditions for this task

Conditions, results and abnormality records for this operation
To defineDetails
Actual operating conditionsAnalytical target, filter material/pore size, filtration location, added volume, actual pressure drop and permitted maintenance
Acceptance targetCompare analytes, recovery and blanks before and after filtration. Check pressure drop and actual flow after loading accumulates, and the first sample after replacement.
Fault localizationBlockage, adsorption, leakage or added filter-assembly volume can change the sample and its arrival time.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
PE-Series FiltersParticle retention permitted by the methodCards show representative configurations. Select actual pore size and filter material for the target, pressure drop and recovery requirements.
Tubing materials and dimensionsConnection paths and shared volumeBore, length, load and actual formulation jointly determine materials and dimensions
Rigid-tubing fittingsTube-end positioning and sealed connectionsCheck tube outer diameter, threads, seal structure and port-bottom geometry
  • PE-Series Filters
  • Tubing materials and dimensions
  • Rigid-tubing fittings

06Validate operation results at the receiver

Compare analytes, recovery and blanks before and after filtration. Check pressure drop and actual flow after loading accumulates, and the first sample after replacement.

Compare process and collected samples, checking target retention, contamination and reactor-volume changes.

07Locate abnormalities and restore the next operation

Clogging, adsorption, leakage or added filter-assembly volume can change the sample and arrival time.

Confirm the filtration path and sealing, then recheck actual flow, sample renewal and method results before resuming.

Removing cell aggregates may change the measured target. Reduced valve-body contact through a pinch valve does not make the entire path sterile.

References

View references (3)
  1. [1]FOREACH PE series filters: configurations and specifications
  2. [2]FOREACH tubing materials and dimensions: configurations and specifications
  3. [3]FOREACH rigid-tubing fittings: configurations and specifications

Related guides

  • Return to the online sampling overview
  • Fluidic Connections and Protection for Online Sampling

Related Products

PE-Series Filters; representative configuration. Select capacity, materials and interfaces for the application.

PE-Series Filters

Tubing materials and dimensions; representative configuration. Select capacity, materials and interfaces for the application.

Tubing materials and dimensions

Rigid-tubing fittings; representative configuration. Select capacity, materials and interfaces for the application.

Rigid-tubing fittings

Related Technical Articles

What is flow resistance calculation for? Using the Foreach calculator in fluid-path design and selection

The free flow rate of the pump meets the requirements. After installing the pipelines, valves and joints, the liquid supply at the end is insufficient. Flow resistance calculations can break the problem down into comparable data: what pressure differential is required at the target flow rate, where does the pressure loss mainly occur, and what happens if the pipe diameter, pipe length, component Cv or medium viscosity is changed. This article combines the actual function of the Foreach flow resistance calculator with a recalculable fluid circuit case to explain how to use the calculation results for design, selection, troubleshooting and prototype verification.

2026-09-11View Details

Why Does Actual Flow Change So Much When the Tubing Size Changes on the Same Miniature Diaphragm Pump?

Even when the pump is unchanged, installed flow can change because of tubing inner diameter, length, bends, and the minimum bore of fittings. When flow falls after a tubing change, the effective response is neither to blame the pump first nor to enlarge every tube indiscriminately. Measure inlet pressure, outlet pressure, and accumulated flow together to determine where the added restriction actually occurs.

2026-08-24View Details

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Discuss fluidic configurations for online sampling

Provide a fluidic diagram, actual liquids and pressures in each operating state. Cards show representative configurations; choose actual pore size and filter material for the analyte, pressure drop and recovery. Select tubing material and dimensions using bore, length, load and formulation. Check OD, threads, sealing structure and port-bottom geometry. Compare configurations against this guide's validation objectives.