Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/In Vitro Diagnostics/Molecular diagnostics
< Back

Diaphragm pumps in molecular diagnostics

Application guide

Focusing on required wash-station supply and aerated-waste aspiration in molecular diagnostics, this page explains diaphragm-pump location, coordination and configuration conditions, linking to related operating and validation tasks.

Applicable architecture

The workflow uses a diagnostic workstation with nucleic-acid extraction as an example. Magnetic-bead extraction can use pipetting or magnetic rods that transfer beads; binding, washing and elution do not all require pump-driven fixed fluidics. Distinguish liquid-moving actions, solid-phase transfer and downstream setup before discussing components.[5]

Application guide

Molecular diagnostics

Molecular diagnostics
Diaphragm pumps in molecular diagnostics
Bubble and pressure sensing in molecular diagnostics
Tubing and fittings in molecular diagnostics
Multiport rotary valves in molecular diagnostics
Isolation of reagent, nucleic-acid eluate and waste paths
Air-displacement pipetting pumps in molecular diagnostics
Tip-based washing and nucleic-acid eluate transfer
Syringe pumps in molecular diagnostics
Lysis and binding reagent dispensing through fixed fluidics

On this page

What do these products do in this instrument?Define liquid-supply and aerated-aspiration branches separatelyMatch supply/removal capacity to washing-station and container conditionsTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageConfirm product roles in actual operationDo similar nominal supply- and waste-pump flow rates make a matched pair?ReferencesRelated guides

01What do these products do in this instrument?

Liquid diaphragm pumps: wash-station supply where required

Supply wash fluid to existing cleaning stations, coordinating wash heads and waste removal to restore wetted surfaces. Magnetic-rod separation is organized around solid-phase motion; identify liquid-pumping operations separately.

Compare DPL30, DPL60 and DPL30H by actual supply load. Wash-head, valve, tubing and container resistance jointly determine installed flow; check the supply window and receiving position together.

Gas–liquid diaphragm pumps: aerated-waste branch aspiration

Remove waste in suitable aerated-aspiration or container-vacuum architectures. Keep destinations clearly distinct from nucleic-acid eluate reception, and include contamination boundaries in maintenance and reverse-leakage checks.

DPGL800 handles gas or gas–liquid aspiration permitted by its specific configuration. Check inlet gas content, foam, peak inflow and container vacuum; use a separately suitable solution for continuous liquid-only transfer.

02Define liquid-supply and aerated-aspiration branches separately

Suitable liquid diaphragm-pump configurations supply wash heads, stations or working vessels. Gas–liquid diaphragm pumps serve permitted aerated aspiration or related container-vacuum architectures. Describe actual inlet medium and gas–liquid state first, then determine pump position, incoming source and discharge destination.

Further technical reading

  • What Are Cleaning, Wash and Rinse Pumps in IVD Systems, and Why Are Miniature Diaphragm Pumps Used?
  • How to Read a Diaphragm Pump Flow-Pressure Curve—and Predict Installed Flow
  • IVD Waste Aspiration: Liquid Pump or Vacuum Pump? Direct vs Indirect Aspiration

03Match supply/removal capacity to washing-station and container conditions

Installed flow depends jointly on pump, tubing, valves, wash head and container; free flow does not directly represent station delivery. Evaluate supply by effective coverage and available time, and waste removal by peak inflow, lift, permitted residual liquid and full-container state. Check the complete wash cycle when supply and aspiration must be coordinated.

04Translate actual branch conditions into configuration requirements

Diaphragm-pump configuration conditions in molecular diagnostics
ConditionTo confirm
Inlet mediumDistinguish liquid-only flow, intermittent gas entrainment and foam, and confirm the aspiration modes permitted by the configuration.
Tubing and containersProvide suction lift, outlet load, tubing and waste-container conditions.
Actual supply and removalMeasure incoming liquid, residue and emptying at the station; check handling after full level, shortage or blockage.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
DPL30 liquid diaphragm pumpLiquid supply or auxiliary circulationSelect by installed resistance, actual wash or working fluid and task window
DPL60 liquid diaphragm pumpLiquid supply or auxiliary circulationJudge by peak demand and installed operating point, not free flow alone
DPL30H high-backpressure liquid diaphragm pumpLiquid branches requiring higher backpressure capabilityCalculate pressure budget and actual flow first, then confirm interfaces and materials
DPGL800 gas–liquid diaphragm pumpSuitable gas–liquid aspiration or container-vacuum branchesConfirm inlet medium and waste architecture; not for continuous liquid-only transfer (100% liquid)
  • DPL30 liquid diaphragm pump

    DPL30 liquid diaphragm pump

    View Details
  • DPL60 liquid diaphragm pump

    DPL60 liquid diaphragm pump

    View Details
  • DPL30H high-backpressure liquid diaphragm pump

    DPL30H high-backpressure liquid diaphragm pump

    View Details
  • DPGL800 gas–liquid diaphragm pump

    DPGL800 gas–liquid diaphragm pump

    View Details

06Confirm product roles in actual operation

Check recovered volume, extracted nucleic-acid usability and between-sample contamination, maintaining separation of wash fluid and waste.

07Do similar nominal supply- and waste-pump flow rates make a matched pair?

Compare peak inflow, effective aspiration and permissible accumulation in the actual installation. The branches may handle different media and operating windows; validate station recovery over the complete sequence.

Valve switching or low dead volume alone does not prove contamination isolation for extracted nucleic acid and amplification setup.

References

View references (5)
  1. [1]FOREACH DPL30 liquid diaphragm pump: configurations and specifications
  2. [2]FOREACH DPL60 liquid diaphragm pump: configurations and specifications
  3. [3]FOREACH DPL30H high-backpressure liquid diaphragm pump: configurations and specifications
  4. [4]FOREACH DPGL800 gas–liquid diaphragm pump: configurations and specifications
  5. [5]Thermo Fisher KingFisher: binding, washing and elution by transferring magnetic beads

Related guides

  • Back to the molecular-diagnostic fluidics overview

Related Products

DPL30 Liquid diaphragm pumps

DPL30 Liquid diaphragm pumps

DPL60 Liquid diaphragm pumps

DPL60 Liquid diaphragm pumps

DPL30H High-backpressure liquid diaphragm pumps

DPL30H High-backpressure liquid diaphragm pumps

DPGL800 Gas–liquid diaphragm pumps

DPGL800 Gas–liquid diaphragm pumps

Related Technical Articles

What Are Cleaning, Wash and Rinse Pumps in IVD Systems, and Why Are Miniature Diaphragm Pumps Used?

Cleaning pump, wash pump and rinse pump usually name different duties within an IVD cleaning sequence, not three fixed pump mechanisms. Selection starts with wash volume, cycle rate, line resistance, wetted materials, and whether the duty is liquid supply or waste aspiration.

2026-09-03View Details

How to Read a Diaphragm Pump Flow-Pressure Curve—and Predict Installed Flow

A catalogue value such as 300 or 600 mL/min is not a fixed flow rate inside an instrument. The useful engineering question is: at the actual inlet pressure, outlet backpressure, fluid, tubing and supply voltage, where will the pump and the fluidic circuit settle?

2026-07-28View Details

IVD Waste Aspiration: Liquid Pump or Vacuum Pump? Direct vs Indirect Aspiration

Probe washing, reaction-cup cleaning, and routine waste removal in IVD instruments are all described as “waste aspiration.” Yet whether waste passes directly through a liquid pump or first enters a collection bottle while a vacuum pump creates negative pressure leads to entirely different selection logic.

2026-08-09View Details

Discuss Your IVD Fluidic Requirements

Share the instrument type, sample and reagent properties, working volumes, cycle timing, fluid path and acceptance criteria so we can discuss suitable components and prototype evaluation.