Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/In Vitro Diagnostics/Molecular diagnostics
< Back

Molecular diagnostics: fixed-path lysis and binding reagent dispensing

Application guide

Fixed-path lysis and binding reagent dispensing is a specific liquid-handling operation in molecular diagnostics. This page explains product responsibilities, sequence, actual conditions and recovery requirements. Establish the architecture before comparing configurations.

Applicable architecture

The workflow uses a diagnostic workstation with nucleic-acid extraction as an example. Magnetic-bead extraction can use pipetting or magnetic rods that transfer beads; binding, washing and elution do not all require pump-driven fixed fluidics. Distinguish liquid-moving actions, solid-phase transfer and downstream setup before discussing components.[3]

Application guide

Molecular diagnostics

Molecular diagnostics
Diaphragm pumps in molecular diagnostics
Bubble and pressure sensing in molecular diagnostics
Tubing and fittings in molecular diagnostics
Multiport rotary valves in molecular diagnostics
Isolation of reagent, nucleic-acid eluate and waste paths
Air-displacement pipetting pumps in molecular diagnostics
Tip-based washing and nucleic-acid eluate transfer
Syringe pumps in molecular diagnostics
Lysis and binding reagent dispensing through fixed fluidics

On this page

Where fixed-path lysis and binding reagent dispensing occurs in the instrumentProduct responsibilities in this operationOrganize the sequence by actual architectureDefine operating conditions for this taskCompare product configurations by the roles on this pageValidate operation results at the receiverLocate abnormalities and restore the next operationReferencesRelated guides

01Where fixed-path lysis and binding reagent dispensing occurs in the instrument

Manage doses, materials and mixing separately for lysis solution, binding solution and beads. Choose fixed paths or disposable tips by sample contamination, formulation and actual workload, paying attention to first doses after idle and particle condition.

Confirm materials and action conditions separately for lysis and binding solutions. Record sample identity, target well and completed delivery steps; one water sequence cannot cover all working liquids.

02Product responsibilities in this operation

Syringe drive and valve positions jointly organize aspiration, holding and dispensing. Record working volume, remaining inventory and replenishment timing according to the sequence.

For this operation, confirm: Lysis, binding and particle-containing formulations; source valves; fixed-path materials; priming destination; working dose; target well; mixing and processing sequence.

03Organize the sequence by actual architecture

  1. Confirm that the architecture requires fixed fluidic supply, listing lysis, binding and other reagent formulations, sample positions and target containers.
  2. Prime and aspirate with the syringe at the corresponding source-valve position, directing shared residue to its specified destination.
  3. Deliver reagents in assay order, coordinated with separately defined mixing and processing times. The pump delivers liquid; that action alone cannot establish completion of lysis or binding.
  4. Check actual received volume, subsequent nucleic-acid recovery and contamination blanks separately, retaining source and sample identity records for recovery decisions.

04Define operating conditions for this task

Conditions, results and abnormality records for this operation
To defineDetails
Actual operating conditionsLysis, binding and particle-containing formulations; source valves; fixed-path materials; priming destination; working dose; target well; mixing and processing sequence
Acceptance targetMeasure each lysis or binding reagent at the intended receiving well using its actual formulation and source path. Include first doses after standby or replenishment and verify the order of completed additions.
Fault localizationAn empty source, air entry, shared reagent residue or wrong receiving well can alter extraction conditions. Replaying a completed pump command may duplicate a reagent addition without restoring an interrupted extraction.

Further technical reading

  • What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation
  • Piston Pump Accuracy, Repeatability and Resolution Explained

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
HLD rotary-valve syringe pumpAspiration, holding and dispensing with a rotary valveCheck source/outlet valve positions, capacity budget and replenishment timing
HMD solenoid-valve syringe pumpMetered aspiration and dispensing with solenoid valvesCheck open/closed and power-off states, working volume and replenishment cycle
  • HLD rotary-valve syringe pump

    HLD rotary-valve syringe pump

    View Details
  • HMD solenoid-valve syringe pump

    HMD solenoid-valve syringe pump

    View Details

06Validate operation results at the receiver

Measure each lysis or binding reagent at the intended receiving well using its actual formulation and source path. Include first doses after standby or replenishment and verify the order of completed additions.

Assess subsequent nucleic-acid recovery and contamination blanks with the complete extraction method. Keep these results separate from volume checks and from the mixing or processing time required for lysis and binding.

07Locate abnormalities and restore the next operation

An empty source, air entry, shared reagent residue or wrong receiving well can alter extraction conditions. Replaying a completed pump command may duplicate a reagent addition without restoring an interrupted extraction.

Hold the affected wells and reconcile sample identity, reagent source and volume already received. Restore the source and priming path, then follow the extraction method for partially processed samples before resuming reagent delivery.

This task applies to fixed-path reagent supply. A completed delivery does not prove lysis or binding, and magnetic-rod or disposable-tip architectures require their own handling sequence.

References

View references (3)
  1. [1]FOREACH HLD rotary-valve syringe pump: configurations and specifications
  2. [2]FOREACH HMD solenoid-valve syringe pump: configurations and specifications
  3. [3]Thermo Fisher KingFisher: binding, washing and elution by transferring magnetic beads

Related guides

  • Back to the molecular-diagnostic fluidics overview
  • Syringe pumps in molecular diagnostics

Related Products

HLD Rotary-valve syringe pumps

HLD Rotary-valve syringe pumps

HMD Solenoid-valve syringe pumps

HMD Solenoid-valve syringe pumps

Related Technical Articles

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Piston Pump Accuracy, Repeatability and Resolution Explained

Learn why theoretical volume per step is not the minimum reliable dose, and how accuracy, repeatability, valves, bubbles and working stroke affect dispensing results.

2026-09-06View Details

Discuss Your IVD Fluidic Requirements

Share the instrument type, sample and reagent properties, working volumes, cycle timing, fluid path and acceptance criteria so we can discuss suitable components and prototype evaluation.

Discuss your application