Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Laboratory automation/Sample preparation platforms
< Back

Sample Preparation Workstations: Washing and Product Recovery

Application guide

Washing and recovery are specific liquid-handling operations in sample preparation platforms. This page explains component roles, action sequence, actual operating conditions and restart requirements. Establish the architecture before comparing configurations.

Application guides

Sample preparation platform application guide

Sample preparation platform fluidics overview
Syringe pumps in sample preparation platforms
Air-displacement pipetting pumps in sample preparation platforms
Disposable-tip sample transfer
Diaphragm pumps in sample preparation platforms
Washing and product recovery
Multiport rotary valves in sample preparation platforms
Path scheduling
Bubble and pressure detection in sample preparation platforms
Tubing and fittings in sample preparation platforms

ON THIS PAGE

Where washing and product recovery occur in the instrumentProduct responsibilities in this operationOrganize the sequence by actual architectureDefine operating conditions for this taskCompare product configurations by the roles on this pageValidate operation results at the receiverLocate abnormalities and restore the next operationReferencesRelated guides

01Where washing and product recovery occur in the instrument

Coordinate wash supply, aspiration, elution and waste resources across stations. Maintain defined product and waste destinations, assess residual liquid and recovery against method results, and include priming and washing in cycle timing.

When several stations wash simultaneously, shared supply and waste removal can become bottlenecks. Calculate peak demand first, then assess residual liquid and recovery through the complete workflow.

02Product responsibilities in this operation

Diaphragm pumps perform suitable liquid supply or aerated aspiration in this task. Confirm inlet phase, branch location and outlet destination separately, then check each branch's operating point.

Compare DPL30, DPL60 and DPL30H by actual supply load. Wash-head, valve, tubing and container resistance jointly determine installed flow; check the supply window and receiving position together.

DPGL800 handles gas or gas–liquid aspiration permitted by its specific configuration. Check inlet gas content, foam, peak inflow and container vacuum; use a separately suitable solution for continuous liquid-only transfer.

For washing and product recovery, confirm solid-phase location and retention target, wash cycles, aspiration height, residual liquid, destinations and downstream requirements.

03Organize the sequence by actual architecture

  1. Identify the solid phase or product at each station, wash-liquid sources, waste destinations and eluate receivers. Confirm the separation architecture used.
  2. Reserve the pipetting, supply or drainage resources required by the workstation configuration. Confirm reservation and state of shared pumps, valves and wash stations first.
  3. Perform wash-waste removal, elution and product collection separately according to the method, checking aspiration height and destinations. Organize magnetic-rod transfers around solid-phase movement.
  4. Check residual liquid, recovery and contamination before releasing shared resources and handing over sample status. On restart, use the completed volume to determine where to resume.

04Define operating conditions for this task

Conditions, results and abnormality records for this operation
To defineDetails
Actual operating conditionsSolid-phase location and retention target, wash cycles, aspiration height, residue, destination and downstream assay requirements
Acceptance targetTest the intended concurrent station load on shared wash and drainage resources. At each station, verify solid-phase or product retention, residual liquid and the separate destinations for discarded wash fluid and collected eluate.
Fault localizationA shared supply or waste bottleneck can leave one station incompletely washed while another finishes. Incorrect aspiration height or an uncertain destination can lose product despite an apparently completed platform schedule.

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
DPL30 liquid diaphragm pumpLiquid supply or auxiliary circulationSelect by installed resistance, actual wash or working fluid and task window
DPL60 liquid diaphragm pumpLiquid supply or auxiliary circulationJudge by peak demand and installed operating point, not free flow alone
DPL30H high-backpressure liquid diaphragm pumpLiquid branches requiring higher backpressure capabilityCalculate pressure budget and actual flow first, then confirm interfaces and materials
DPGL800 gas–liquid diaphragm pumpSuitable gas–liquid aspiration or container-vacuum branchesConfirm inlet medium and waste architecture; not for continuous liquid-only transfer (100% liquid)
  • DPL30 liquid diaphragm pump
  • DPL60 liquid diaphragm pump
  • DPL30H high-backpressure liquid diaphragm pump
  • DPGL800 gas–liquid diaphragm pump

06Validate operation results at the receiver

Test the intended concurrent station load on shared wash and drainage resources. At each station, verify solid-phase or product retention, residual liquid and the separate destinations for discarded wash fluid and collected eluate.

Check method-relevant recovery and contamination results before handing the sample to the next station. Keep resource availability, completed volume and sample status consistent at the handoff.

07Locate abnormalities and restore the next operation

A shared supply or waste bottleneck can leave one station incompletely washed while another finishes. Incorrect aspiration height or an uncertain destination can lose product despite an apparently completed platform schedule.

Hold the affected stations and retain their resource reservations and sample identities until states are reconciled. Establish which wash, aspiration or collection actions completed, restore supply and drainage, and resume only the step permitted by the sample state and method.

Successful platform operation does not replace assessment of nucleic acid, cell or analytical method results.

References

View references (4)
  1. [1]FOREACH DPL30 liquid diaphragm pump: configurations and specifications
  2. [2]FOREACH DPL60 liquid diaphragm pump: configurations and specifications
  3. [3]FOREACH DPL30H high-backpressure liquid diaphragm pump: configurations and specifications
  4. [4]FOREACH DPGL800 gas–liquid diaphragm pump: configurations and specifications

Related guides

  • Return to the sample preparation workstation overview
  • Diaphragm pumps in sample preparation platforms

Related Products

DPL30 liquid diaphragm pump; representative configuration. Select capacity, materials and interfaces for the application.

DPL30 liquid diaphragm pump

DPL60 liquid diaphragm pump; representative configuration. Select capacity, materials and interfaces for the application.

DPL60 liquid diaphragm pump

DPL30H high-backpressure liquid diaphragm pump; representative configuration. Select capacity, materials and interfaces for the application.

DPL30H high-backpressure liquid diaphragm pump

DPGL800 gas–liquid diaphragm pump; representative configuration. Select capacity, materials and interfaces for the application.

DPGL800 gas–liquid diaphragm pump

Related Technical Articles

How to Read a Diaphragm Pump Flow-Pressure Curve—and Predict Installed Flow

A catalogue value such as 300 or 600 mL/min is not a fixed flow rate inside an instrument. The useful engineering question is: at the actual inlet pressure, outlet backpressure, fluid, tubing and supply voltage, where will the pump and the fluidic circuit settle?

2026-07-28View Details

Selecting a Self-Priming Miniature Liquid Diaphragm Pump: Lift, Priming Time and Dry or Wet Starts

Select a self-priming miniature liquid diaphragm pump by checking suction lift, time to first liquid, dry and wet starting conditions, and stable delivery. Use DPL30, DPL60 and DPL30H specifications to define an instrument-level test.

2026-09-07View Details

What is a programmable automatic air-displacement pipetting pump?

A programmable automatic air-displacement pipetting pump is a liquid-handling component whose aspiration, dispense, speeds and sequence are set through control commands. This article focuses on air-displacement modules that use disposable tips in OEM instruments, with FOREACH SMTP2 as an example of operation, monitoring and selection limits.

2026-09-28View Details

Discuss fluidic configurations for your sample preparation workstation

Provide a fluidic diagram, actual liquids and pressures in each operating state. Select using installed resistance, actual wash or working liquid and task duration. Assess peak demand and the installed operating point rather than free flow alone. Calculate the pressure budget and actual flow before confirming interfaces and materials. Identify the inlet medium and waste-removal architecture; the gas-liquid option is not for continuous transfer of 100% liquid. Compare suitable configurations against this guide's validation objectives.

Contact an engineer