Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/In Vitro Diagnostics/Clinical chemistry analyzer
< Back

Clinical chemistry reagent dispensing: capacity, replenishment and first-dose recovery

Application guide

Clinical chemistry reagents, diluent and common working fluids may use different paths and cycles. Piston metering provides controlled displacement; probe-tip outflow, valve switching and cuvette reception determine the volume actually added to the reaction. First distinguish each liquid's purpose.

Application guide

Clinical chemistry analyzer

Clinical chemistry analyzer
Diaphragm pumps in clinical chemistry analyzers
Probe/cuvette wash supply and waste removal
Bubble and pressure detection in clinical chemistry analyzers
Tubing and fittings in clinical chemistry analyzers
Multiport rotary valves in clinical chemistry analyzers
Sample, reagent and wash-path switching
Piston pumps in clinical chemistry analyzers
Metered reagent dispensingSample aspiration and transfer
Sampling and wash probes in clinical chemistry analyzers
Syringe pumps in clinical chemistry analyzers

On this page

Locate the source, drive and receiving position for this taskCalculate dose, total cycle volume and replenishment time togetherCompare product options against task requirementsPriming and first-dose recovery support cuvette deliveryCompare first, middle and last doses with actual reagentAfter an abnormality or maintenance, first identify which segment needs recoveryContinue with tasks on the same branchReferencesRelated guides

01Locate the source, drive and receiving position for this task

Reagent bottle→Priming and metering→Dispensing probe→Reaction cuvette
Functional or operational sequence; confirm connections and branches for each state on the instrument

Required inputs are dose per operation, total cycle volume, replenishment/bottle-change interval, backpressure and receiving geometry. Confirm liquid contact, pressure and destination along the diagram before assigning drive and connection responsibilities.

The Roche GLUC3 method lists reagent and water additions separately. Preserve that distinction when budgeting this channel: a combined reaction addition is not the volume of neat reagent. The method is an engineering example, not evidence that the original analyzer uses FOREACH components.[1]

02Calculate dose, total cycle volume and replenishment time together

Select by dose, total cycle volume, replenishment interval and permissible pauses. Command resolution helps compare control margin but does not establish the minimum reliable dose. Provide actual reagent viscosity, temperature and material-contact conditions as well.

Compare configuration conditions by actual task
Condition to compareInformation requiredSelection affected
Workload per doseDose volume, number of doses and cuvette receptionDefine the routine stroke
Replenishment schedulingUsable capacity, replenishment time and test cycleKeep replenishment out of steps that cannot be interrupted
Reagent conditionActual formulation, settling or droplet retention, and standbyDefine first-dose recovery

Further technical reading

  • What Is a Precision Piston Pump? Working Principle, Benefits and Applications
  • Piston Pump Accuracy, Repeatability and Resolution Explained
  • Choosing a 100, 250 or 500 μL Piston Pump for Clinical Chemistry Dosing

03Compare product options against task requirements

The following candidate options match this page's responsibilities. Compare them against the operating conditions described, then check capacity, materials and interfaces on the product pages. Card images show representative configurations; suitability must still be confirmed at actual operating points and by application results.

Move from task conditions to product configuration
Product categoryCorresponding roleConfirm before selection
EA standard piston pumpFinite-stroke meteringCompare configurations by routine dose, total cycle displacement and wetted materials
SM miniature piston pumpDiscrete metering in compact installationsCheck installation space first, then validate working doses and actual accuracy
TM ultra-miniature piston pumpDiscrete metering in limited spaceCheck installation space and configuration before measuring actual delivery; an ultra-miniature design does not imply a smaller reliable dose
  • EA standard piston pump

    EA standard piston pump

    View Details
  • SM miniature piston pump

    SM miniature piston pump

    View Details
  • TM ultra-miniature piston pump

    TM ultra-miniature piston pump

    View Details

04Priming and first-dose recovery support cuvette delivery

After replenishment, bottle changes or long standby, restore an effective liquid column before dispensing working doses. Nozzle droplets or entering air may mainly affect the first dose. The controller must track replenishment state and affected cuvettes to avoid duplicate dispensing.

Keep a per-cuvette record of the reagent source, completed additions, remaining usable inventory and refill state. Distinguish a completed pump motion from actual reception, particularly at the first and final doses of a batch or during a source change.

05Compare first, middle and last doses with actual reagent

Measure first, middle and final doses at the actual probe and receiving cuvette with the reagent or justified test medium. Include the first dose after replenishment, bottle changes and the longest planned idle interval; relate volume and residue to the reaction ratios, blanks and assay results.

Link operating-point tests to interpretable results
Validation scenarioMeasurement or observationInterpretation and action
Dose-to-dose differencesMeasure first, middle and last doses separatelyIf only the first dose is abnormal, check priming and nozzle state
Recovery after bottle changeChange bottles and reprime through the actual pathVerify delivery to the first cuvette before resuming normal timing

Use a volume-verification method to quantify each relevant transfer while adjusting the operating sequence. Albert and Bradshaw show why measured transfer results are useful during liquid-handler optimization; their results do not validate a particular FOREACH reagent dose or replace complete-assay testing.[11]

06After an abnormality or maintenance, first identify which segment needs recovery

Source depletion, air entry, nozzle droplets or backpressure changes can affect first or final doses. Identify the affected source and cuvettes before priming, and keep recovery liquid separate from useful reagent additions.

Reconcile remaining inventory and every completed or partial cuvette addition before restarting. Restore the source and effective liquid column, verify the first useful dose, and apply the assay procedure to uncertain reactions without repeating additions already completed.

  • Bring the fluidic diagram and operating-point records to discuss configuration

07Continue with tasks on the same branch

  • Clinical chemistry sample transfer: from sampling architecture to probe-tip delivery

References

View references (11)
  1. [1]Roche — Glucose HK Gen.3, cobas c 303 / c 503 / c 703, V7.0 (2024)
  2. [2]Beckman Coulter — Alanine Aminotransferase, SYNCHRON / UniCel DxC, A18452 AU
  3. [3]FOREACH — Piston-pump head and wetted-material selection
  4. [4]CDC / NHANES — Sodium, Roche Cobas 8000 Laboratory Procedure Manual (2021–2023)
  5. [5]FOREACH — EA Piston Pump Datasheet, capacities and test conditions
  6. [6]FOREACH — EA-100-PEEK configuration and specifications
  7. [7]Tecan — Liquid handling pump selection: a guide for lab automation engineers
  8. [8]FOREACH — EAS Easy-to-Degas Piston Pump Datasheet
  9. [9]Beckman Coulter — Glucose, AU / DxC AU, BAOSR6X21
  10. [10]IDEX Health & Science — Degassing and bubble control
  11. [11]Albert and Bradshaw — Importance of Integrating a Volume Verification Method for Liquid Handlers: Applications in Learning Performance Behavior (2007)

Related guides

  • Back to the clinical chemistry analyzer fluidics overview
  • Piston pumps in clinical chemistry analyzers
  • Sample aspiration and transfer

Related Products

EA Standard piston pumps

EA Standard piston pumps

SM Miniature piston pumps

SM Miniature piston pumps

TM Ultra-compact piston pumps

TM Ultra-compact piston pumps

Related Technical Articles

What Is a Precision Piston Pump? Working Principle, Benefits and Applications

Learn how precision piston pumps work, where they are used and how to select capacity, performance, materials, valves and controls for an OEM fluidic system.

2026-06-19View Details

Piston Pump Accuracy, Repeatability and Resolution Explained

Learn why theoretical volume per step is not the minimum reliable dose, and how accuracy, repeatability, valves, bubbles and working stroke affect dispensing results.

2026-09-06View Details

Choosing a 100, 250 or 500 μL Piston Pump for Clinical Chemistry Dosing

Compare dose volume, stroke utilization, dispensing count and refill timing, then assess Foreach EA, SM and TM configurations using the actual clinical chemistry fluid path.

2026-09-08View Details

Discuss Your IVD Fluidic Requirements

Share the instrument type, sample and reagent properties, working volumes, cycle timing, fluid path and acceptance criteria so we can discuss suitable components and prototype evaluation.

Discuss your application