FOREACH
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control Series
Applications
IVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About FOREACHR&D and ManufacturingQuality System and QualificationsMilestonesFOREACH Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About FOREACH
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • FOREACH Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Products/Piston Pump/EA-100-PEEK
FOREACH 100 μL Precision Piston Pump for Specialty Reagent Dispensing and Small-Volume Reaction Systems, with a PEEK Pump Head for Fluid Paths Requiring Material Compatibility and Light Protection

FOREACH 100 μL Precision Piston Pump for Specialty Reagent Dispensing and Small-Volume Reaction Systems, with a PEEK Pump Head for Fluid Paths Requiring Material Compatibility and Light Protection

EA-100-PEEK is a 100 μL precision piston pump with a PEEK pump head for microliter reagent addition in clinical chemistry and immunoassay analyzers, small-volume sample handling and reaction-liquid addition in life science instruments. It supports 1/4-28 UNF or M6 ports and 2000 full-stroke steps. Accuracy and repeatability at 100% full stroke are both ≤0.5% under the specified test conditions.

The displayed PEEK pump head can be replaced by a project-matched PMMA or PCTG option. Piston choices include zirconia ceramic, alumina ceramic, PEEK and sapphire. Ports, motor, optical feedback, valves and controls can be configured to the instrument. All wetted materials must be assessed against reagent composition and operating conditions.

Typical Applications:

Reagent dosing, Sample dilution, Buffer and reaction-liquid addition, Reagent metering and standard addition

Model:This product is custom-made
Volume100 μL
Displayed pump head materialPolyether ether ketone (PEEK)
Pump head material optionsPCTG / PMMA / PEEK; Other engineering materials can be assessed for fluid compatibility, structural strength, manufacturing process and project volume.
Piston material optionsZirconia ceramic / alumina ceramic / polyether ether ketone (PEEK) / sapphire; the combination is assessed for fluid properties, service-life requirements, installation space and project needs.
Fluidic interface1/4-28 UNF / M6
Stroke12.7 mm
Recommended max speed600 RPM
Motor step angle1.8° / 0.9°
Lead1.27 mm
Full-stroke steps2000 Step
Accuracy at 100% stroke≤0.5%
Repeatability at 100% stroke≤0.5%
Accuracy at 2% stroke≤2.0%
Repeatability at 2% stroke≤1.5%
Backlash≤1.0%
Designed life5 million cycles
Max fluid pressure<0.30 MPa

Typical applications of the 100 μL PEEK-head precision piston pump

EA supports metered liquid handling in clinical chemistry, immunoassay, laboratory automation, sample preparation and water or environmental analysis. Project configurations can also be assessed for life science and omics instruments, diagnostic reagent filling and industrial liquid dosing. Tasks include reagent addition, dilution, standard addition, buffer dispensing, reaction-liquid addition, solution preparation, metered washing and priming. Depending on its role, it may be described as a reagent, dilution, standard-addition, dispensing or reagent-filling pump. Titrant addition requires additional minimum-dose validation.

EA-100-PEEK focuses on microliter reagent addition in clinical chemistry and immunoassay analyzers, small-volume sample handling and reaction-liquid addition in life science instruments. The 100 μL capacity and smaller nominal volume per step support the design of small-volume aspiration and staged dispensing sequences. The displayed PEEK head is a material option for specialty reagents. It does not establish compatibility of all wetted parts or light protection for the entire fluid path. The scenarios below connect instrument requirements with configurable capabilities; suitability is subject to application validation.

1. Reagent dispensing pumps for clinical chemistry and immunoassay analyzers

Clinical chemistry and immunoassay analyzers add defined reagent volumes to reaction units. A reagent dispensing pump must support consistent repeated doses and coordinated operation with selector valves, dispensing probes and instrument controls.

EA-100-PEEK: Specified full-stroke accuracy and repeatability are both ≤0.5% under the stated test conditions. Motor, home-position optical sensor and valve options support integration; small-dose performance must be verified using the actual reagent and working volume.

2. Sample dilution pumps for automated sample preparation

Sample-preparation instruments control sample and diluent volumes separately to achieve a programmed dilution ratio. A sample dilution or diluent dosing pump must coordinate repeated aspiration, dispensing, valve switching and between-sample washing.

EA-100-PEEK: 1/4-28 UNF or M6 ports connect to the instrument fluid path, with valves and a controller coordinating aspiration and dispensing. Pump full-stroke specifications are not a guarantee of dilution-ratio accuracy; working volumes, backlash compensation, residual liquid and mixing must also be assessed.

3. Buffer dispensing pumps for life science and omics instruments

Sample preparation in life science and omics instruments can require staged buffer, reagent and reaction-liquid addition. Buffer dispensing and reagent pumps must follow programmed doses while coordinating fluid switching and cleaning.

EA-100-PEEK: Wetted-material, valve and control options support the design of a metered addition unit. Omics applications need additional residual-volume, adsorption and carryover validation; cell- or particle-containing samples require separate assessment.

4. Reagent metering and standard-addition pumps for water analyzers

Water and environmental analyzers meter reagents, standards or diluents. A reagent metering or standard-addition pump must control dose volume while matching reagent composition, concentration and cleaning conditions.

EA-100-PEEK: Pump-head, piston and valve materials can be matched to the fluid. The EA specification includes an optional seal-wash arrangement for maintenance planning with crystallization-prone liquids. This option does not establish universal reagent compatibility or replace fluid and cycling tests. The displayed PEEK head is a material option for specialty reagents. It does not establish compatibility of all wetted parts or light protection for the entire fluid path.

Application selection guidance

100 μL is the nominal capacity; nominal volume per step is approximately 0.05 μL. Neither is a validated minimum dose. Provide working volume, allowed error, timing, reagent, temperature and back pressure for configuration-specific testing. The specification footnotes describe the 2% stroke figures as displacement tests, not direct measurements of reagent dispensing.

The specified expected life of five million cycles uses pure water at room temperature and 50 kPa back pressure. Saline or crystallization-prone fluids require a maintenance procedure. Pressure, seal wash, feedback and driver options follow the formal specification and project configuration. Omics, titration and filling require further carryover, minimum-dose, dripping or process validation.

Loading 3D model...
Preview DrawingView the technical drawing for FOREACH 100 μL Precision Piston Pump for Specialty Reagent Dispensing and Small-Volume Reaction Systems, with a PEEK Pump Head for Fluid Paths Requiring Material Compatibility and Light Protection.

Datasheet not yet available

The datasheet for this product has not been uploaded yet.

Frequently Asked Questions

This configuration targets microliter reagent addition in clinical chemistry and immunoassay analyzers, small-volume sample handling and reaction-liquid addition in life science instruments. The 100 μL capacity and smaller nominal volume per step support the design of small-volume aspiration and staged dispensing sequences. Suitability depends on the fluid, working volume and instrument timing.

No. The 2000 full-stroke steps give a nominal 0.05 μL per step. This is capacity divided by steps. The minimum reliable dose also depends on backlash, valves, bubbles, fluid and tubing and requires testing.

No. These figures apply at full stroke under the specified conditions. The 2% stroke figures are ≤2.0% accuracy and ≤1.5% repeatability; the footnotes describe displacement testing, not a guarantee of reagent performance at arbitrary small doses.

The displayed PEEK head is a material option for specialty reagents. It does not establish compatibility of all wetted parts or light protection for the entire fluid path. Head options include PMMA, PCTG and PEEK. Piston options include zirconia ceramic, alumina ceramic, PEEK and sapphire. Seals and other wetted parts must be considered together.

Motor, home-position optical sensing, valves and controls can be configured for the project. Closed-loop feedback and an ISC1000 integrated driver are listed options; the driver supports RS-232, RS-485 and CAN. Home sensing and motion feedback are distinct functions.

Check all wetted materials against composition, concentration and temperature and plan shutdown flushing and residual-liquid handling. Seal wash is a listed EA option. The expected five-million-cycle life uses pure water at room temperature and 50 kPa back pressure and is not a universal reagent-life guarantee.

Provide EA-100-PEEK or the target capacity, dose volume, allowed error, timing, fluid composition, temperature, back pressure, mounting space and control requirements. The page model identifies a display configuration; final materials, ports and assemblies are project-specific.

Related Technical Articles

How to Select a Piston Pump Head Material

Compare PMMA, PCTG, PPS, PVDF, PP, PTFE, PEEK, POM and PSU pump-head options, and learn how to validate the complete wetted path.

2026-09-06View Details

Piston Pump Accuracy, Repeatability and Resolution Explained

Learn why theoretical volume per step is not the minimum reliable dose, and how accuracy, repeatability, valves, bubbles and working stroke affect dispensing results.

2026-09-06View Details

What Is a Precision Piston Pump? Working Principle, Benefits and Applications

Learn how precision piston pumps work, where they are used and how to select capacity, performance, materials, valves and controls for an OEM fluidic system.

2026-06-19View Details

Acceleration and Deceleration Curves for Piston-Pump Drives

Use stepper-motor torque-speed behavior to select linear, S-curve or parabolic motion profiles and prevent missed steps in piston-pump aspiration and dispensing.

2026-09-06View Details

Precision Piston Pump Backlash Compensation Guide

Understand reversal backlash, measurement methods and compensation timing, and distinguish mechanical lost motion from actual aspirated or dispensed volume.

2026-09-06View Details

Precision Piston Pump Stepper Motor Calculation and Selection

Calculate pulse frequency, microstepping, transmission ratio and load torque, then verify speed and dynamic torque with a 400 mm reciprocating-platform example.

2026-09-06View Details

Piston Pump Configured for Your Instrument

Share the target volume, fluid compatibility, port type, control method, installation space, and service-life requirements. The FOREACH engineering team can help confirm the pump configuration and wetted materials.

Submit a Custom Request