  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/In Vitro Diagnostics/Hematology analyzer
< Back

Syringe pumps in hematology analyzers

Application guide

Focusing on diluent and sample transfer in hematology analyzers, this page explains syringe-pump location, coordination and configuration conditions, linking to related operating and validation tasks.

Applicable architecture

Hematology analyzers may use different detection principles and channel configurations. Diluent, lysing reagent and sheath-fluid locations depend on the specific method; sheath-flow conditions do not apply to every counting channel.[3]

Application guide

Hematology analyzer

Hematology analyzer
Diaphragm pumps in hematology analyzers
Hematology-channel cleaning and waste removal
Bubble and pressure sensing in hematology analyzers
Tubing and fittings in hematology analyzers
Multiport rotary valves in hematology analyzers
Detection-channel switching and fluid renewal
Piston pumps in hematology analyzers
Whole-blood sampling and delivery
Sampling probes in hematology analyzers
Syringe pumps in hematology analyzers
Diluent and reaction-reagent metering

On this page

What do these products do in this instrument?Organize syringe metering around aspiration, holding and dispensingMap valve connections to every actionTranslate actual branch conditions into configuration requirementsCompare product configurations by the roles on this pageExplore specific operating and validation tasksConfirm product roles in actual operationFor repeated dispensing from one chamber, is checking total volume enough?ReferencesRelated guides

01What do these products do in this instrument?

Syringe pumps: diluent and sample transfer

Organize sample transfer or diluent delivery in syringe-driven branches, using valves and reaction positions to prepare the required ratio. If the method uses lysing reagent, check its actual dose separately.

HLD and HMD organize aspiration/dispensing paths with rotary and solenoid valves respectively. Capacity budgets include useful volume, holding stages and replenishment points; valve states and pump actions together create each delivery.

02Organize syringe metering around aspiration, holding and dispensing

Syringe drives use controlled displacement for aspiration, holding and dispensing. With direct contact, source liquid enters the metering chamber; with system-liquid drive, sample can remain at the probe tip or a designated tube segment. Define wetted coverage before capacity, cleaning and replenishment. For repeated dispensing, track current inventory, delivered volume and next replenishment time.

Further technical reading

  • What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation
  • Piston Pump Accuracy, Repeatability and Resolution Explained

03Map valve connections to every action

Check port connections, opening/closing sequence and power-off state separately for rotary- and solenoid-valve configurations. Changing source does not automatically remove old liquid from the chamber or shared tubing. Plan flushing for formulation and residue requirements, then evaluate the first dose after switching and dose-to-dose variation.

04Translate actual branch conditions into configuration requirements

Syringe-pump configuration conditions in hematology analyzers
ConditionTo confirm
Stored volume and timingDefine volume per operation, consecutive dispensing count, holding time and permitted replenishment window.
Valve positions and destinationsProvide a source, receiver and waste port diagram with open/closed and power-off states.
Liquid changes and first doseCheck shared residue, priming destination and actual received volume after standby or source changes.
Operations supported in this instrument
OperationSpecific operating conditions
Diluent and reaction-reagent meteringActual volumes of original sample, diluent or internal standard; concentrations at each stage; mixing and resampling conditions

05Compare product configurations by the roles on this page

Configuration options for the product roles on this page
ProductConfiguration optionConditions to verify
HLD rotary-valve syringe pumpAspiration, holding and dispensing with a rotary valveCheck source/outlet valve positions, capacity budget and replenishment timing
HMD solenoid-valve syringe pumpMetered aspiration and dispensing with solenoid valvesCheck open/closed and power-off states, working volume and replenishment cycle
  • HLD rotary-valve syringe pump

    HLD rotary-valve syringe pump

    View Details
  • HMD solenoid-valve syringe pump

    HMD solenoid-valve syringe pump

    View Details

06Explore specific operating and validation tasks

Diluent and reaction-reagent metering

Equal commanded volumes in two branches do not establish the correct final ratio. Check delivery errors, tubing residue and mixing together within the assay-defined dilution step.

  • Diluent and reaction-reagent metering

07Confirm product roles in actual operation

Operating-point validation and fault localization
OperationMeasurements and observationsPriority checks
Diluent and reaction-reagent meteringMeasure each branch's delivery, received ratio and mixing uniformity separately, then check assay responseSmall-volume errors, shared residual liquid or inadequate mixing may alter the actual ratio

Check sampling, ratios and channel recovery with actual whole-blood conditions, and validate supply stability during continuous testing.

08For repeated dispensing from one chamber, is checking total volume enough?

Measure each received dose, especially the first and last. Even when total volume is near target, individual errors may differ. Relate replenishment, valve switching and receiving actions to each result.

Metered dilution and sheath-fluid flow are different roles; sheath-fluid requirements depend on the detection architecture.

References

View references (3)
  1. [1]FOREACH HLD rotary-valve syringe pump: configurations and specifications
  2. [2]FOREACH HMD solenoid-valve syringe pump: configurations and specifications
  3. [3]Sysmex hematology analyzer reference: impedance and fluorescence flow-cytometry configurations

Related guides

  • Back to the hematology analyzer fluidics overview
  • Diluent and reaction-reagent metering

Related Products

HLD Rotary-valve syringe pumps

HLD Rotary-valve syringe pumps

HMD Solenoid-valve syringe pumps

HMD Solenoid-valve syringe pumps

Related Technical Articles

What Is a Programmable Syringe Pump? Operation, Fluid Routing and Automation

A programmable syringe pump uses a motor to control syringe plunger displacement and speed, executing aspiration, dispensing, pauses and repeated actions through commands. With a routing valve, it can connect reagent reservoirs, reaction vessels and wash paths into an automated dispensing process. Instrument development therefore needs to define volume, fluid connections and timing together.

2026-09-28View Details

Piston Pump Accuracy, Repeatability and Resolution Explained

Learn why theoretical volume per step is not the minimum reliable dose, and how accuracy, repeatability, valves, bubbles and working stroke affect dispensing results.

2026-09-06View Details

Discuss Your IVD Fluidic Requirements

Share the instrument type, sample and reagent properties, working volumes, cycle timing, fluid path and acceptance criteria so we can discuss suitable components and prototype evaluation.

Discuss your application