FOREACH
Home
Products
Applications
Resources
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control Series
Applications
IVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About FOREACHR&D and ManufacturingQuality System and QualificationsMilestonesFOREACH Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About FOREACH
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • FOREACH Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Miniature Diaphragm Pumps/DPL30-BB
FOREACH 300 mL/min Brushless DC Miniature Liquid Diaphragm Pump, 12 V / 24 V

FOREACH 300 mL/min Brushless DC Miniature Liquid Diaphragm Pump, 12 V / 24 V

The FOREACH DPL30 Series Brushless Liquid Diaphragm Pump is designed for liquid transfer, with a no-load flow rate of 300 mL/min, a pressure rating of 100 kPa, a brushless motor, and a service life of 10000 h. It is suitable for cleaning-solution transfer, reagent transfer, waste-liquid discharge, line priming, and liquid circulation, and can be selected for IVD, life science, laboratory automation, and analytical instrument applications. It is suitable for equipment that requires a longer operating life and longer maintenance intervals. Refer to the specification table below for detailed parameters.

Typical Applications:

Cleaning-solution transfer, reagent transfer, waste-liquid discharge, line priming, liquid circulation

Model:This product is custom-made
Motor TypeBrushless DC Motor
Product TypeDiaphragm Pump
Rated VoltageDC 24V ±10% / DC 12V ±10%
Rated Power≤8 W
Free-Flow Rate300 mL/min
Rated Pressure100 kPa
Self-Priming Height6 mH₂O
Working MediumPurified water; other fluids require evaluation
Fluid Temperature+5 °C–+80 °C
Port SizeAccepts tubing with an ID of 3.2 mm
Noise≤80 dB
Operating Temperature+5 °C–+40 °C
Operating Relative Humidity30%–85% RH
Storage Temperature-10 °C–+40 °C
Storage Relative Humidity10%–90% RH
Pump Head MaterialPP S
Diaphragm MaterialEPDM / PTFE
Valve MaterialEPDM / FFKM
Service Life10,000 h
Loading 3D model...
Preview DrawingView the technical drawing for FOREACH 300 mL/min Brushless DC Miniature Liquid Diaphragm Pump, 12 V / 24 V.

Datasheet not yet available

The datasheet for this product has not been uploaded yet.

Frequently Asked Questions

It can be used to transfer cleaning solutions, reagents, waste liquids, and other liquids in instrument fluid paths. Before selection, confirm the compatibility of the liquid with the diaphragm, valves, pump head, and other wetted materials.

The no-load flow rate is 300 mL/min and the pressure rating is 100 kPa. Actual flow may decrease as tubing resistance and operating pressure increase.

The brushless version has a service life of 10000 h, while the brushed version has a service life of 3000 h. The brushless version is more suitable for equipment with longer operating periods or longer maintenance-interval requirements.

It can be selected for cleaning-solution transfer, reagent transfer, waste-liquid discharge, line priming, and liquid circulation in IVD equipment.

Confirm the liquid medium, target flow rate, pressure, continuous operating time, start-stop frequency, wetted materials, supply voltage, tubing resistance, and installation space.

Related Videos

View All 4

Related Technical Articles

How Do You Choose Between a 300 mL/min and 600 mL/min Miniature Diaphragm Pump? Calculate Task Flow First, Then Check the Actual Operating Point

The 300 mL/min and 600 mL/min values are flow classes first, not fixed outputs after installation in an instrument. Selection should begin by converting the liquid-handling task into a minimum average flow rate, then determining the differential pressure required by the actual fluid path, and finally confirming the operating point on the pump curve and in prototype testing.

2026-08-26View Details

How Much Installed Flow Margin Should a 300 mL/min Miniature Diaphragm Pump Have? A FOREACH Example

Flow margin is not found by multiplying the target flow by 1.2 or 1.3 in every case. It is determined by comparing the pump's conservative available flow with the instrument's maximum demand within the same credible worst-case scenario. Testing must also define in advance how measurement uncertainty will be handled and what explicit acceptance criteria will apply.

2026-08-26View Details

Why Does Actual Flow Change So Much When the Tubing Size Changes on the Same Miniature Diaphragm Pump?

Even when the pump is unchanged, installed flow can change because of tubing inner diameter, length, bends, and the minimum bore of fittings. When flow falls after a tubing change, the effective response is neither to blame the pump first nor to enlarge every tube indiscriminately. Measure inlet pressure, outlet pressure, and accumulated flow together to determine where the added restriction actually occurs.

2026-08-26View Details

Which Has a Greater Effect on a Miniature Diaphragm Pump: Suction-Line or Discharge-Line Resistance?

Pressure loss on either the suction or discharge side increases the differential pressure carried by a miniature diaphragm pump, but there is no universal rule that one side is always more important. The suction side more readily affects initial priming, chamber filling, sensitivity to air leakage, outgassing, and cavitation. The discharge side more often appears as increased backpressure, reduced flow, and deadheading. Diagnose the system by observing inlet absolute pressure, outlet pressure, and flow on the same time axis.

2026-08-26View Details

What Is the Difference Between Rated Working Pressure, Maximum Output Pressure, Proof Pressure, and Burst Pressure for a Miniature Diaphragm Pump?

A pressure value has engineering meaning only when it is paired with a term definition, test fluid, inlet condition, corresponding flow rate, duration, and acceptance criteria. Rated working pressure can define an operating boundary; maximum output pressure, proof-test pressure, and burst pressure cannot be treated directly as continuous operating points.

2026-08-26View Details

Is 100 kPa Enough? How to Determine Whether a Fluid Path Needs a 600 kPa High-Pressure Miniature Diaphragm Pump

100 kPa and 600 kPa are not simply a standard version and an upgraded version. First complete a pressure budget for the entire fluid path at the target flow, then read the candidate pump curve. A higher pressure rating has value only when the application truly has high backpressure.

2026-08-26View Details

Why Do Brushed Diaphragm Pumps Last Around 3,000 Hours and Brushless Pumps Around 10,000 Hours?

Brushed miniature diaphragm pumps commonly have a reference life of approximately 3,000 hours; brushless versions are often rated around 10,000 hours. The difference reflects commutation, dominant wear mechanisms and the actual duty profile rather than a simple motor-quality ranking.

2026-08-25View Details

How to Read a Diaphragm Pump Flow-Pressure Curve—and Predict Installed Flow

A catalogue value such as 300 or 600 mL/min is not a fixed flow rate inside an instrument. The useful engineering question is: at the actual inlet pressure, outlet backpressure, fluid, tubing and supply voltage, where will the pump and the fluidic circuit settle?

2026-08-24View Details

How Long Can a Miniature Diaphragm Pump Run Continuously? A Duty-Cycle and Life Guide

A pump described as suitable for continuous operation is not a pump with unlimited life. Continuous-duty capability, accumulated service life, calendar life and statistical reliability answer different engineering questions—and all depend on the stated load, fluid, electrical drive and environment.

2026-08-24View Details

2-Wire vs 5-Wire Brushless Diaphragm Pumps: What Is the Difference and Which Should You Choose?

When selecting a miniature diaphragm pump, two lead configurations may be offered for the same type of DC brushless motor: 2-wire and 5-wire. The main difference is not the pump's basic delivery principle, but how much control and operating-status information the equipment requires from the motor.

2026-08-18View Details

How to Select a 300 mL/min Liquid Diaphragm Pump: DPL30 Working Principle and Model Guide

A liquid diaphragm pump is a positive-displacement pump that transfers liquid through the reciprocating motion of a flexible diaphragm. Its main structure includes a pump chamber, diaphragm, inlet valve, outlet valve, and drive mechanism.

2026-08-04View Details

Need help selecting a diaphragm pump?

Share the fluid, flow rate, pressure, self-priming requirements, wetted materials, port type, and installation space. The FOREACH engineering team can help confirm a suitable diaphragm pump configuration.

Contact an Engineer