Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: [email protected]

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Applications/Analytical instruments
< Back

High-Pressure Sample-Loop Injection: Loading and Injection States

Application guide

Sample-loop injection generally separates loading from injection into the analytical path. Port connections determine whether the metering device is exposed to high pressure. Not every autosampler metering branch is necessarily low pressure.

Application guides

Analytical instruments

Analytical instruments Overview
Liquid chromatography systems: locate the fluidic task before selecting pumps and valves
Spectroscopy and elemental analysis
Water analysis units
Analytical Sample Preparation
Analytical system integration
Piston Pumps in Analytical Instruments
Automated dilution with piston pumpsPiston Pump Titration
Syringe pump
Syringe-pump samplingMultiple dispensing with syringe pumpsSyringe-pump standard preparation and over-range sample dilutionSequential injection and flow analysis
Air-displacement pipetting pump
Disposable-Tip Sample TransferTip-based dilution and dispensingTip-based sample preparation
Valveless metering pumps
Repeated Dispensing with Valveless PumpsValveless-pump titrationCarrier-liquid and flow-cell supplyTwo-stream proportioning
Diaphragm pump
Wash-liquid supply and primingWorking-liquid replenishmentAuxiliary liquid circulationGas-liquid waste aspiration
Valves for Analytical Fluidics
MRV3 multi-source selectionHigh-pressure sample-loop injectionDetector Flow Diversion and BypassSolenoid-valve shutoff
Sampling, Washing and Mixing Components
Sampling needlesProbe-wash stationReaction-cup and microplate washingReaction mixing
Fluidic monitoring
Bubble and Liquid-State DetectionPressure and Blockage Monitoring
Tubing, fittings, filters and check valves
Tubing materials and dimensionsLow-retention connectionsFiltration and backflow protection

ON THIS PAGE

Locate the source, drive and receiving position for this taskCheck pressure and volume for the loop-loading modeCompare product options against task requirementsCheck loading, injection and backflushing separatelyValidate using leakage, blanks and peak responseAfter an abnormality or maintenance, first identify which segment needs recoveryContinue with tasks on the same branchReferencesRelated guides

01Locate the source, drive and receiving position for this task

Sample-loading branch→Injection valve and sample loop→High-pressure analytical path→Column or detection path
Functional or operational sequence; confirm connections and branches for each state on the instrument

Valve states connect the loading branch and high-pressure mobile-phase path. Check loading and injection separately. The diagram does not imply that the metering device is always in series with the high-pressure main path.

Define all ports, valve states, pressures in each state, shared volume and displacement volume. Follow the diagram to confirm liquid contact, pressure and destination before assigning drive and connection roles.

02Check pressure and volume for the loop-loading mode

Specify ports, pressures, loop volume and loading mode in each state. Full-loop and partial-loop loading require different sample volumes. Coordinate loading direction, swept volume and materials with the actual method.

Compare configuration conditions by actual task
Condition to compareInformation requiredSelection affected
Loading modeFull-loop, partial-loop and overfill loadingDistinguish total loading volume from effective injection volume
Pressure statesPressure exposure during loading, injection and backflushingVerify pressure rating and switching conditions
Port geometryLoop, probe, fittings and shared volumeCompare actual injection with sample consumption

03Compare product options against task requirements

The following candidate options match this page's responsibilities. Compare them against the operating conditions described, then check capacity, materials and interfaces on the product pages. Card images show representative configurations; suitability must still be confirmed at actual operating points and by application results.

Move from task conditions to product configuration
Product categoryCorresponding roleConfirm before selection
HP high-pressure injection valvePressurized injection-path switchingCheck port pressures and sample loops in loading, injection and other states
  • HP high-pressure injection valve

04Check loading, injection and backflushing separately

Load in the specified state, then switch to injection and wait for pressure or signal recovery. Include backflushing, bypass or needle-washing states in the drawings where relevant.

Action records should link commands, valve or interface states and actual received results. When raw material, container or sample identity changes, reconfirm shared paths and conditions permitting the next step. Completion of drive movement alone does not replace task acceptance.

05Validate using leakage, blanks and peak response

Check actual loop filling, leakage, pressure recovery, carryover and peak response. Matching valve interfaces establishes assembly compatibility only, not direct replacement suitability for an instrument.

Link operating-point tests to interpretable results
Validation scenarioMeasurement or observationInterpretation and action
Switching pressureCheck leakage, pressure recovery and valve stateFor anomalies, locate the affected port and pressure-exposure stage first
Method performanceCompare blanks, peak responses and repeat injectionsSuccessful mechanical switching still requires analytical-method validation

Record test medium, configuration, installed path and operating sequence; present routine operating points and boundary results separately. Calculations support design discussions, component documentation checks models, and installed measurements confirm the actual task.

06After an abnormality or maintenance, first identify which segment needs recovery

Mispositioning, shared-path residue or abnormal switching pressure can affect the next task. Stop pumping and check ports, then flush again after restoring the correct state.

Retain current source, container identity, completed actions, valve or interface state and actual receiving information. Use the table to locate the stage that changed before deciding to retry, continue or restart. After recovery, recheck the relevant operating point before returning an uncertain action to the automatic cycle.

  • Bring the fluidic diagram and operating-point records to discuss configuration

07Continue with tasks on the same branch

  • Analytical fluidic valves: source selection, injection, diversion and isolation
  • MRV3 Multiple-Source Selection: Port Maps, Displacement and Challenging Liquid Combinations
  • Detector Diversion and Bypass: Delay Volume and Switching Disturbance
  • Solenoid Shutoff: Normal State, Energization Cycle and Fault Routing

References

View references (2)
  1. [1]VICI: Sample Injection with a Cheminert 6-Port Valve
  2. [2]FOREACH: High-Pressure Valve Product Range

Related guides

  • MRV3 Multiple-Source Selection: Port Maps, Displacement and Challenging Liquid Combinations
  • Low-Hold-Up Connections: Matching Threads, Tube Ends and Port Geometry
  • Pressure and blockage monitoring: establish action baselines before fault thresholds

Related Products

HP high-pressure injection valve; representative configuration. Select capacity, materials and interfaces for the application.

HP high-pressure injection valve

Related Technical Articles

How Does a 6-Port HPLC Injection Valve Work? Load, Inject and Vent

Follow sample loading into an external loop and transfer to the column by the mobile phase, distinguishing the HP valve's main positions and vent path from the factors that determine injection volume.

2026-09-29View Details

Discuss your high-pressure sample-loop injection fluidics

Provide a fluid-path diagram, actual liquids and pressures in each state. Specify full-loop, partial-loop or overfill loading, pressure exposure during loading, injection and backflushing, and loop, probe, fitting and shared volumes. Compare configurations against the guide's validation objectives.

Contact an engineer